Normas de desempenho no fogo (Inglês) – Fire Performance Cable Standards

Fire Performance Cable Standards - list of the standards for FP cables in the United Kingdom, Germany and internationally.

British Standards

BS 7629-1 : 1997Specification for 300 / 500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire.  Multicore cables.
BS 7629-2 : 1997Specification for 300 / 500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire. Multipair cables.
BSEN 50266-1 : 2001Common test methods for cables under fire conditions.  Test for vertical flame spread of vertically mounted bunched wires of cables.
BSEN 50267-1 : 1999Common test methods for cables under fire conditions.  Tests on gases evolved during combustion of materials from cables.  Procedures. Determination of the amount of halogen acid gas.
BSEN 50267-2-2 : 1999Common test methods for cables under fire conditions.  Test on gases evolved during combustion of materials from cables.  Procedures.  Determination of degree of acidity of gases for materials by measuring pH and conductivity.
BSEN 60079-1 : 2004Electrical apparatus for explosive gas atmospheres : Flameproof enclosures ‘d’
BSEN 60332-1-2 : 2004test on electric and optical fibre cables under fire conditions. Test for vertical flame propagation for a single vertical insulated wire or cable.  Procedure for 1kW pre-mixed flame.
BSEN 60332-1-3 : 2004Tests on electric and optical fibre cables under fire conditions.  Test for vertical flame propagation for a single vertical insulated wire or cable.  Procedure for determination of flaming droplets / particles.
BSEN 60332 – 2 – 2 : 2004Tests on electric and optical fibre cables under fire conditions.  Tests for vertical flame propagation for a single vertical insulated wire or cable.  Procedure for diffusion flame.
BS G 241 : 1988Specification for fire proof electric cables for engine fire zone and airframe use

German Standards

DIN VDE 0266 Part 3 & 4Halogen free cables with improved characteristics in the case of fire, with reduced fire propagation and continuance of isolation for use in the containment of nuclear power plants
DIN VDE 0267Halogen free cables with improved characteristics in the case of fire, nominal voltages from 6 up to 30kV
DIN VDE 0276 Part 604Power cables of nominal voltages 0.6 / 1kV with special fire performance for use in power stations
DIN 4102-12Fire behaviour of building materials and elements – fire resistance of electric cable systems required to maintain circuit integrity – requirements and testing
DIN 4102-9Fire behaviour of building materials and elements – seals for cable penetrations ; concepts, requirements and testing

International Standards

IEC 60331-11Tests for electric cables under fire conditions – circuit integrity – Part 11 : apparatus – fire alone at a flame temperature of at least 750oC
IEC 60331-12Tests for electric cables under fire conditions – circuit integrity – Part 12 : apparatus – fire with shock at a temperature of at least 830oC
IEC 60331-21Tests for electric cables under fire conditions – circuit integrity – Part 21 : procedures and requirements – cables of rated voltage up to an dincluding 0.6 / 1.0kV
IEC 60331-23Tests for electric cables under fire conditions – circuit integrity – Part 23 : procedures and requirements – electric data cables
IEC 60331-25Tests for electric cables under fire conditions – circuit integrity – Part 25 : procedures and requirements – optical fibre cables
IEC 60331-31Tests for electric cables under fire conditions – circuit integrity – Part 31 : procedures and requirements for fire with shock – cables of rated voltage up to and includign 0.6 / 1.0 kV
IEC 60332-1-1Tests on electric and optical fibre cables under fire conditions part 1 : test for vertical flame propagation for a single insulated wire or cable Section 1 : apparatus
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions Part 1 : test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame
IEC 60332-1-3Test on electric and optical fibre cables under fire conditions Part 1 : test for vertical flame propagation for a single insulated wire or cable Section 3 : procedure for determination of flaming droplets / particles
IEC 60332-2-1Tests on electric and optical fibre cables under fire conditions Part 2 : test for vertical flame propagation for a single small insulated wire or cable Section 1 : apparatus
IEC 60332-2-2Tests on electric and optical fibre cables under fire conditions Part 2 : test for vertical flame propagation for a single small insulated wire or cable Section 2 : procedure for diffusion flame
IEC 60332-3-10Tests on electric cables under fire conditions Part 3 : test for vertical flame spread of vertically mounted bunched wires or cables Section 10 : apparatus
IEC 60332-3-21Tests on electric cables under fire conditions Part 3 : test for vertical flame spread of vertically mounted bunched wires or cables Section 21 : category A F/R
IEC 60332-3-23Tests on electric cables under fire conditions Part 3 : test for vertical flame spread of vertically mounted bunched wire or cables Section 23 : category B
IEC 60332-3-24Tests on electric cables under fire conditions Part 3 : test for vertical flame spread of vertically mounted bunched wire or cables Section 24 category C
IEC 60332-3-25Tests on electric cables under fire conditions Part 3 : test for vertical flame spread of vertically mounted bunched wires or cables Section 25 category D
IEC / TR 6222Fire performance of communication cables installed in buildings