Control Cables - NBR 7289 / 7290 / 16442

Control cables - NBR 7290

    INNOVCABLE CONTROL CABLE SB XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Polyester tape separator.
    4) Thermoplastic compound covering based on polyvinyl chloride (PVC/ ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The INNOVCABLE Control Cable SB XLPE-HEPR/PVC - NBR 7290, can be manufactured in another section, dimensional or material at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    OTHER CONSTRUCTION OPTIONS:
    We can manufacture on request in other configurations.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection in aluminized polyester tape against electromagnetic interferences. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BF XLPE-HEPR/PVC - NBR 7290 control cable can be manufactured in other sections, dimensions or materials as requested by the customer. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PE - 80 ºC
    4- Cover material:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex).

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF FC XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in copper tape.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper tape against electromagnetic interference. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BF FC XLPE-HEPR/PVC - NBR 7290 control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to change this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF FA XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel tape.
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Isolation resistance

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection of galvanized steel tape. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BF FA XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF BTC XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in copper braid.
    6) Non-hygroscopic ribbon
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-roof gutters, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper braid against electromagnetic interference. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BF BTC XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF BTA XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel braid.
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection of galvanized steel braid. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BF BTA XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BTC XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in bare copper braid
    6) Non-hygroscopic ribbon
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    -Isolation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    -Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in alternate current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-rails, electrical panels, among other applications. It has EMV electromagnetic interference protection. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BTC XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BTA XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel braid
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has mechanical protection of galvanized steel braid. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BTA XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other sections, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BFA XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel tape shield
    6) Non-hygroscopic tape, if applicable.
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-roof gutters, electrical panels, among other applications. They are mechanically protected by galvanized steel strips. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    EE in permanent regime: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BFA XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BFC XLPE-HEPR/PVC - NBR 7290

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Composite insulation (HEPR - ethylene-propylene rubber) or XLPE 90ºC.
    3) Separator in polyester tape.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Copper tape shield
    6) Non-hygroscopic tape, if applicable.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Black or white veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 - Control cables with XLPE, EPR or HEPR extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-rails, electrical panels, among other applications. It has copper tape protection against electromagnetic interference. This cable has good flexibility, resistance to UV, weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    In steady state: +90°C
    Maximum short circuit temperature: +250°C (5s)

    Notes

    The BFC XLPE-HEPR/PVC CONTROL CABLE - NBR 7290, can be manufactured in other section, dimensions or material, at the customer's request.

    Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    PVC/A - 70 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español