Marine Cables - IEC Standard

0,6/1kV Naval instrumentation cables

INNOVCABLE INNOVSHORE INSTRUMENTATION BF 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
5) Covering in halogen-free polyolefinic compound LSOH (SHF1), in gray colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION BLINDED BF Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Non-halogen and anti-flame cable, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE INSTRUMENTATION BFI 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
5) Halogen-free polyolefin LSOH (SHF1) cover, in gray colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION BFI __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION BLINDED BFI Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, as well as maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE INSTRUMENTATION BFIC 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
5-) Collective shielding in aluminum-polyester tape, with flexible drainage conductor, formed by electrolitic tinned copper wires, soft temper.
5) Covering in halogen-free polyolefin compound LSOH (SHF1), in grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION Cables BLINDED BFIC 0,6/1kV are recommended in cases where excellent levels of protection against external electromagnetic interferences are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED INSTRUMENTATION ATC/ATS 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
5) Polyester Tape.
6) Frame: bare copper wire braid (ATC) or tinned copper wire (ATS) with coverage >90% *8
7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS __mm² 0.6/1kV 90°C OF: XXXX/YE.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED ATC/ATS 0.6/1kV Instrumentation Cables have excellent flexibility, resistance to chemical products, humidity and UV rays. Reinforced cable with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATC - Bare copper wire braided frame
ATS - Tinned copper braid frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED INSTRUMENTATION ATA/AFC/AFA 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
5) Inner jacket made of halogen-free polyolefin LSOH compound (SHF1). *5
6) Frame: Galvanized steel wire braid (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED ATA/AFC/AFA 0,6/1kV Instrumentation Cables have excellent flexibility, resistance to chemical products, humidity and UV rays. Reinforced cable with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATA - Galvanized steel wire braid frame
AFC - Copper tape frame
AFA - Galvanized steel tape frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATA/AFC/AFA BF 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
5) Internal cover in halogen-free polyolefinic compound (SHF1). *5
6) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/BLINDED ATA/AFC/AFA BF 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/interiors, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATA - Galvanized steel wire braid frame
AFC - Copper tape frame
AFA - Galvanized steel tape frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED/PLUGGED ATA/AFC/AFA BFI 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
5) Internal cover in halogen-free polyolefinic compound (SHF1). *5
6) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey in colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFI __mm² 0.6/1kV 90°C OF: XXXX/YE.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/BLINDED ATA/AFC/AFA BFI 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATA - Galvanized steel wire braid frame
AFC - Copper tape frame
AFA - Galvanized steel tape frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED/PLUGGED ATA/AFC/AFA BFIC 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
5) Collective shield in aluminum-polyester tape, with flexible drainage conductor, formed by electrolitic tinned copper wires, soft temper.
6) Internal cover in halogen-free polyolefinic compound (SHF1). *5
7) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
8) Cover in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5

Identification

- External Recording:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATA/AFC/AFA BFIC 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATA - Galvanized steel wire braid frame
AFC - Copper tape frame
AFA - Galvanized steel tape frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED/PLUGGED ATC/ATS BF 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
5) Polyester tape / extruded filling.
6) Frame: bare copper wire braid (ATC) or tinned copper wire (ATS) with coverage >90% *8
7) LSOH halogen-free polyolefin compound (SHF1) cover, grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATC/ATS BF 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, as well as maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATC - Bare copper wire braided frame
ATS - Tinned copper braid frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED/PLUGGED ATC/ATS BFI 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
5) Polyester tape.
6) Frame: braided bare copper (ATC) or tinned copper (ATS) wires, coverage >90%.* 8
7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFI __mm² 0.6/1kV 90°C OF: XXXX/YE.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/BLINDED ATC/ATS BFI 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of "crosstalk" (crosstalk) between the various pairs/interiors, providing electrical discharge thereof. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATS - Tinned copper wire braided frame
ATC - Bare copper braid frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español

INNOVCABLE INNOVSHORE ARMED/PLUGGED ATC/ATS BFIC 0.6/1kV

1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
2) Insulation in special halogen-free compound LSOH (HF-90). *4
3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
5) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
6) Polyester tape.
7) Armature: braided bare copper (ATC) or tinned copper (ATS) wires, coverage >90%.* 8
8) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

Identification

- External Engraving:
INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

Of the conductors - through the colours of the insulation, being:
black and white (cables in pairs)
black, white and red (cables in pairs).
black, white, red and green (cables in blocks).*3

Identification through sequential numbering.

Applicable Specifications

Strings: IEC 60228
Electrical installations in ships - Power cables for 1 kV and 3 kV voltages - IEC 60092-353
Selection and installation of electrical cables: IEC 60092-352.
Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
Mobile and fixed offshore units - Electrical installations - Part 4: Cables - IEC 61892-4
Low Smoke emission: IEC 61034- 1/2
Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
Shipborne energy cables - General construction and testing requirements: IEC 60092-350
Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
Halogen Free: IEC-60754-1/2
Application: IEC 60092 series.

Applications

Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATC/ATS BFIC 0,6/1kV Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, as well as maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

Maximum Conductor Temperature

CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C

Notes

* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
We can manufacture other colours on request.
3) Different sections and amount of veins, maximum up to:
- 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
- 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
- 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATS - Tinned copper wire braided frame
ATC - Bare copper braid frame

**Innovcable reserves the right to change this catalogue without prior notice.

Download PDF português Download PDF EnglishDownload PDF Español