Control Cables - NBR 7289 / 7290 / 16442

Control cables - NBR 7289

    INNOVCABLE CONTROL CABLE SB

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A) 70ºC.
    3) Polyester tape separator.
    4) Thermoplastic compound based on polyvinyl chloride (PVC/ST1) cover.

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7289 - Control cables with PE or PVC extruded insulation for voltages up to 1 kV - Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    Notes

    The SB CONTROL CABLE can be manufactured in another section, dimensions or material at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    OTHER CONSTRUCTION OPTIONS:
    We can manufacture on request in other configurations.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection in aluminized polyester tape against electromagnetic interferences. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Cover material:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex).

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF FC

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in copper tape.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-roof gutters, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper tape against electromagnetic interference. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF FC control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous (Ex) areas

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF FA

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel tape.
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Isolation resistance

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection of galvanized steel tape. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF FA control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous (Ex) areas

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF BTC

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in copper braid.
    6) Non-hygroscopic ribbon
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-roof gutters, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper braid against electromagnetic interference. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF BTC control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous (Ex) areas

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BF BTA

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shield in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel braid.
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection of galvanized steel braid. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF BTA control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BTC

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in bare copper braid
    6) Non-hygroscopic ribbon
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    -Isolation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    -Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in alternate current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-rails, electrical panels, among other applications. It has EMV electromagnetic interference protection. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    - Flame retardant

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BTC control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    OTHER CONSTRUCTION OPTIONS:
    We can manufacture on request in other configurations.
    1-Plated copper conductor.
    Class 2 stranding.
    2-Different sections, colours and number of veins, maximum up to:
    -71 x 0,50mm² / 71 x 2,50mm².
    -52 x 4,00mm².
    -42 x 6,00mm²
    -20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4-Material of the intermediate layer and the cover
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BTA

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Shielding in galvanized steel braid
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, cable trays, electrical panels, among other applications. It has mechanical protection of galvanized steel braid. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT-CIRCUIT MODE: 160ºC
    - Flameproof

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with IEC 60332-3-23 (Category B)

    Notes

    The BTA control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BFA

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Polyvinyl chloride based thermoplastic compound (PVC/A) insulation.
    3) Polyester tape separator.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel tape shield
    6) Non-hygroscopic tape
    7) Covering in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-roof gutters, electrical panels, among other applications. They are mechanically protected by galvanized steel strips. This cable has good flexibility, resistance to UV, bad weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT-CIRCUIT MODE: 160ºC
    - Flameproof

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with IEC 60332-3-23 (Category B)

    Notes

    The BFA CONTROL CABLE can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL CABLE BFC

    1) Stranded conductor formed by electrolytic bare copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Polyvinyl chloride based thermoplastic compound (PVC/A) insulation.
    3) Polyester tape separator.
    4) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Copper tape shield
    6) Non-hygroscopic tape
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    - Insulation voltage:
    Up to 1,0mm² - 500V
    From 1,50mm² to 10,00mm² - 1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electric tension in Alternate Current
    Insulation resistance.

    Identification

    Sequentially numbered white veins, can be manufactured on customer request with a green track (protective conductor). It can also be built with coloured veins.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/end cap in XLPE or HEPR/PVC-change codes)
    ABNT: NBR 13248 (when manufactured with insulation/end cap in HEPR/LSZH-change codes).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/end cap - codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signalling circuits of electrical equipment, structured cabling, machine connections, push buttons, power supply, microprocessor systems, in the automation of substations, power plants, industrial and chemical areas, among others.
    They are applied in fixed systems of conduits (embedded or exposed), ducts, duct banks, electro-rails, electrical panels, among other applications. It has copper tape protection against electromagnetic interference. This cable has good flexibility, resistance to UV, weather, humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT-CIRCUIT MODE: 160ºC
    - Flameproof

    flame-retardant / self-extinguishing - meets the flame-retardance requirement in accordance with IEC 60332-3-23 (Category B)

    Notes

    The BFC control cable can be manufactured in other sections, dimensions or materials at the customer's request. Innovcable reserves the right to modify this catalogue without prior notice.

    CONSTRUCTION OPTIONS:
    We can manufacture on request in other configurations.
    1- Tinned Copper Conductor.
    Class 2 stranding.
    2- Different sections, colours and number of veins, maximum up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    3- Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE - 125 ºC
    HEPR - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Cover perfectly cylindrical for applications with cable glands in classified areas (Ex)

    Download PDF português Download PDF EnglishDownload PDF Español