AIRPORT SIGNALING CABLES

Airport cables

    INNOVCABLE CABLE FOR AIRPORT LIGHTING – NBR 7732 3.6/6kv SB

    -Conductor material: Stranded conductor formed from bare electrolytic copper wires, soft temper, stranding class 2 NBR NM 280.
    - Conductor class: NBR NM 280 class 2 stranding.
    - Insulation: EPR/B elastomeric compound or XLPE reticulated polyethylene in natural color.
    - PVC/ST2 105 °C outer jacket.
    - Manufactured in black RAL 9005, or any other color requested by the customer.
    - Nominal voltage: 3.6/6Kv.
    - Conductor resistance: according to DIN VDE 0295 class 2 and IEC 60228 cl. 2

    Identification

    INNOVCABLE AIRPORT CABLE 3.6/6Kv XX mm² NBR 7732 OF: XXXX/YEAR

    Applicable Specifications

    NBR 7732 - Electrical cables for lighting aids in airports, at a voltage of 3.6 kV/6 kV
    IEC 60228 CLASS 2 - ABNT NBR NM 280
    NBR 5111 - Circular section bare copper wire for electrical purposes - Specification
    NBR 6242 - Dimensional verification for electrical wires and cables - Test method
    NBR 6251 - Construction of power cables with extruded solid insulation for voltages from (1 to 35) kV - Standardization
    NBR 6813 - Electric wires and cables - Insulation resistance test - Test method
    NBR 6880 - Copper conductors for insulated cables - Dimensional characteristics - standardization
    NBR 6881 - Electric power or control wires and cables - Electrical voltage test - Test method
    NBR NM-IEC60332-1 - Test methods for electric cables under fire conditions - Part 1: Test on a single conductor or insulated cable in vertical position.

    Applications

    Cable for use in airport lighting system. The high dielectric strength insulation guarantees reliability for the electrical systems of taxiways, landing strips and take-off strips at airports. These cables are flame-resistant and self-extinguishing, as verified by the NM-IEC 60332-1 test.

    Maximum Conductor Temperature

    Maximum temperature in permanent regime: 90°C;
    Maximum overload temperature: 130°C;
    Maximum short-circuit temperature: 250°C.

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE LIGHTING - NBR 7732 3.6/6kv SHIELDED LV/BFC

    -Conductor material: Stranded conductor formed from bare electrolytic copper wires, soft temper, stranding class 2 NBR NM 280.
    - Conductor class: NBR NM 280 class 2 stranding.
    - Insulation: EPR/B elastomeric compound or XLPE cross-linked polyethylene in natural color.
    - Shielding in copper tape (BFC) or copper mesh (BT).
    - PVC/ST2 105 °C outer cover.
    - Manufactured in black RAL 9005, or any other color requested by the customer.
    - Nominal voltage: 3.6/6Kv.
    - Conductor resistance: according to DIN VDE 0295 class 2 and IEC 60228 cl. 2

    Identification

    INNOVCABLE AIRPORT CABLE 3.6/6Kv LV OR BTC XX mm² NBR 7732 OF: XXXX/YEAR

    Applicable Specifications

    NBR 7732 - Electrical cables for lighting aids in airports, at a voltage of 3.6 kV/6 kV
    IEC 60228 CLASS 2 - ABNT NBR NM 280
    NBR 5111 - Circular section bare copper wire for electrical purposes - Specification
    NBR 6242 - Dimensional verification for electrical wires and cables - Test method
    NBR 6251 - Construction of power cables with extruded solid insulation for voltages from (1 to 35) kV - Standardization
    NBR 6813 - Electric wires and cables - Insulation resistance test - Test method
    NBR 6880 - Copper conductors for insulated cables - Dimensional characteristics - standardization
    NBR 6881 - Electric power or control wires and cables - Electrical voltage test - Test method
    NBRNM-IEC60332-1 - Test methods for electric cables under fire conditions - Part 1: Test on a single conductor or insulated cable in vertical position.

    Applications

    Cable for use in airport lighting system. The high dielectric strength insulation guarantees reliability for the electrical systems of taxiways, landing strips and take-off strips at airports. These cables are flame-resistant and self-extinguishing, as verified by the NM-IEC 60332-1 test.

    Maximum Conductor Temperature

    Maximum temperature in permanent regime: 90°C;
    Maximum overload temperature: 130°C;
    Maximum short-circuit temperature: 250°C.

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 C UNSHIELDED 5KV

    - Conductor: Class B copper according to ASTM B3, B8 and B33
    - Semiconductor layer: Extruded semiconductor layer or helically applied semiconductor tape
    - Insulation: Cross-linked polyethylene (XLPE) or EPR/B.
    - Manufactured in black RAL 9005, or any other color requested by the customer (green, blue, red, etc.).
    - Nominal voltage: 5.0 KV

    Identification

    INNOVCABLE __ X AWG 5000V XLPE 90{D}C FAA-L824, TYPE C UNSHIELDED

    Applicable Specifications

    Soft or annealed copper wire ASTM B3
    Concentric stranded copper conductors ASTM B8
    ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
    ICEA S-96-659 (NEMA WC 71) 2001-5000 V Unshielded cables
    FAA Specification L-824 C

    Applications

    Airport lighting cable is built for underground use in accordance with the requirements of (FAA) L-824 C for airport lighting circuits (AC 150/5345-53D), (AC 150/5345-7F). Airport cable is available from #8 AWG to #4 AWG. Class B bare annealed copper conductors, insulated with XLPE or EPR/B cross-linked polyethylene resistant to abrasion, moisture and heat. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Normal operating temperature: +90° C
    - Emergency operating temperature: +130° C
    - Short circuit temperature: 250° C

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 C UNSHIELDED (SHEATHED) 5KV

    - Conductor: Bare stranded copper.
    - Insulation: Cross-linked polyethylene (XLPE) or EPR/B.
    - Outer jacket: PE or PVC.
    - Manufactured in black RAL 9005.
    - Nominal voltage: 5.0 KV

    Identification

    INNOVCABLE __ X AWG 5000V XLPE 90{D}C FAA-L824, TYPE C SHEATHED

    Applicable Specifications

    NEMA WC74
    FAA AC150/5345-7F
    ICEA S-93-639
    FAA Specification L-824 C

    Applications

    Airport lighting cable is constructed for underground use in accordance with (FAA) L-824 C requirements for airport lighting circuits ((AC 150/5345-7F). Airport cable is available from #8 AWG to #4 AWG. Class B bare annealed copper conductors, insulated with XLPE or EPR/B cross-linked polyethylene resistant to abrasion, moisture and heat. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Normal operating temperature: +90° C
    - Emergency operating temperature: +130° C
    - Short circuit temperature: 250° C

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 C SHIELDED 5KV

    - Conductor: Bare stranded copper.
    - Semiconductor layer: Extruded semiconductor layer.
    - Insulation: Cross-linked polyethylene (XLPE).
    - External semiconductor layer: Helically applied or extruded semiconductor tape.
    - Shielding: Shielded in copper tape or tinned copper mesh.
    - Outer cover: PVC. PE/XLPE can be offered on request.
    - Manufactured in black RAL 9005.
    - Nominal voltage: 5.0 KV

    Identification

    INNOVCABLE __ X AWG 5000V XLPE 90 C FAA-L824, TYPE C SHIELDED

    Applicable Specifications

    FAA AC 150 / 5345-7E
    FAA AC150/5345-7F
    FAA Specification L-824 C
    ICEA S-93-639
    NEMA WC74

    Applications

    Airport lighting cable is constructed for underground use in accordance with the requirements of (FAA) L-824 C for airport lighting circuits FAA AC 150 / 5345-7E, FAA AC150/5345-7F . Airport cable is available from #8 AWG to #4 AWG. Class B bare annealed copper conductors, insulated with XLPE or EPR/B cross-linked polyethylene resistant to abrasion, moisture and heat. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Normal operating temperature: +90° C
    - Emergency operating temperature: +130° C
    - Short circuit temperature: 250° C

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 B SHIELDED 5KV

    - Conductor: Bare stranded copper.
    - Insulation: EPR.
    - Semiconductor layer: Helically applied semiconductor tape.
    - Shielding: Shielded in copper tape.
    - Separator: Separator tape
    - Outer cover: CPE.
    - Manufactured in black RAL 9005.
    - Nominal voltage: 5.0 KV

    Identification

    INNOVCABLE __ X AWG 5000V EPR 90 C FAA-L824, TYPE B SHIELDED

    Applicable Specifications

    FAA AC150/5345-7F
    NEMA WC74
    FAA Specification L-824 B
    ICEA S-93-639

    Applications

    Airport lighting cable is constructed for underground use in accordance with the requirements of (FAA) L-824 B for FAA AC150/5345-7F airport lighting circuits. Class B bare annealed copper conductors, insulated with abrasion-, moisture- and heat-resistant EPR. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Temperature Fixed use: -40°C to +85°C
    - Maximum conductor temperature in normal operation:≤90℃

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 B UNSHIELDED 5KV

    - Conductor: Bare stranded copper.
    - Insulation: EPR.
    - Outer jacket: CPE.
    - Manufactured in black RAL 9005.
    - Nominal voltage: 5.0 KV

    Identification

    INNOVCABLE __ X AWG 5000V EPR 90 C FAA-L824, TYPE B UNSHIELDED

    Applicable Specifications

    FAA AC150/5345-7F
    NEMA WC74
    FAA Specification L-824 B
    ICEA S-93-639

    Applications

    Airport lighting cable is constructed for underground use in accordance with (FAA) L-824 B requirements for FAA AC150/5345-7F airport lighting circuits. Airport cable is available from #8 AWG to #4 AWG. Class B bare annealed copper conductors, insulated with abrasion-, moisture- and heat-resistant EPR. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Temperature Fixed use: -40°C to +85°C
    - Maximum conductor temperature in normal operation:≤90℃

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE AIRPORT CABLE FAA L-824 C 600V

    - Conductor: Stranded bare copper conforming to ASTM B
    - Insulation: XLPE or EPR/B
    - Outer jacket: PVC (only for multiconductors).
    - Manufactured in black RAL 9005.
    - Nominal voltage: 600 V

    Identification

    INNOVCABLE __ X AWG 600V EPR/B 90 C FAA-L824, TYPE C

    Applicable Specifications

    FAA AC150/5345-7F
    NEMA WC71
    FAA Specification L-824 C
    ICEA S-95-658

    Applications

    Airport lighting cable is constructed for underground use in accordance with the requirements of (FAA) L-824 C for FAA AC150/5345-7F airport lighting circuits. Class B bare annealed copper conductors, insulated with abrasion-, moisture- and heat-resistant XLPE or EPR/B. Airport lighting cable is mainly used for series lighting circuits for runways, control systems and other multifunctional installations. It can be used in direct burial, conduit or ducting.

    Maximum Conductor Temperature

    - Temperature Fixed use: -40°C to +90°C
    - Maximum conductor temperature in normal operation:≤90℃

    Notes

    - We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español