Marine Cables - NEK-606/IEC - SHF2 Mud Resistance

Power, control and lighting cables - Fire resistance IEC 60331 - SHF2 Mud resistance

    INNOVCABLE Power, Control and Lighting 0.6/1(1.2)kV BU - P17 - SHF2 Resistance - IEC 60331

    1) Conductor made of tinned electrolytic copper wires, soft temper, stranding class 5, according to IEC 60228. *1
    2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied over the conductors.
    4) Final coating in halogen-free polyolefin compound LSOH (SHF2), in black (Code U).

    Identification

    A-) Number of Conductors (Without Earth G conductor)
    1C: Single conductor - Black or White
    2C: Two conductors - White, Black
    3C: Three conductor - White, Black, Red
    4C: Four conductors - White, Black, Red, Blue
    5C or more: Five conductors or more - Black or White conductors numbered sequentially.

    B-) Number of conductors (with G earth conductor)
    2C +E: Three conductors - White, Black, Green
    3C +E: Four conductors - White, Black, Red, Green
    4C +E: Five conductors - White, Black, Red, Blue, Green
    6C or more: Six or more conductors - Black or white sequentially numbered conductors + green lane

    Engraving on outer cover (example): "year" Innovcable 01 BU 0,6/1kV P17 1 x 70 mm2 IEC 60331-21 IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Fire Resistance: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Marine cables for fixed installations for power, control and lighting in EX environments (Zone 0, 1 and 2) and secure areas (SHF2). Meets resistance requirements according to NEK TS 606 (SHF2). Cables are double-layered, single cables are used as battery cables. IEC 60331 fire-resistant cable.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned copper conductor can be manufactured in class 2.
    2) Operating voltage : 0,6/1(1,2)kV
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE Power, Control and Lighting 0.6/1(1.2)kV BFOU, BFBU, BFCU - P5 and P5/P12 - SHF2 Resistance - IEC 60331

    1) Conductor made of tinned electrolytic copper wires, soft temper, stranding class 5, according to IEC 60228. *1
    2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied over the conductors.
    4) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
    5) Frame: *2
    - Tinned copper wire mesh (Code 0)
    - Bronze wire mesh (Code B)
    - Galvanized steel wire mesh (Code C)
    6) Final cover in halogen-free polyolefin compound LSOH (SHF2), black (Code U)

    Identification

    A-) Number of Conductors (Without Earth G conductor)
    1C: Single conductor - Black or White
    2C: Two conductors - White, Black
    3C: Three conductor - White, Black, Red
    4C: Four conductors - White, Black, Red, Blue
    5C or more: Five conductors or more - Black or White conductors numbered sequentially.

    B-) Number of conductors (with G earth conductor)
    2C +E: Three conductors - White, Black, Green
    3C +E: Four conductors - White, Black, Red, Green
    4C +E: Five conductors - White, Black, Red, Blue, Green
    6C or more: Six or more conductors - Black or white sequentially numbered conductors + green lane

    Engraving on outer cover (example): "year" Innovcable 01 BFOU 0.6/1KV P5/P12 3 x 2.5 mm2 - FLAME IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Fire Resistance: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Marine cables for fixed installations for power, control and lighting in EX environments (Zone 0, 1 and 2) and secure areas (SHF2). Meets resistance requirements according to NEK TS 606 (SHF2). IEC 60331 fire-resistant cable.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned Copper Conductor can be manufactured in class 2.
    2) Tape can be applied before/after the frame.
    3) Operating voltage : 0,6/1(1,2)kV
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE Frequency Inverter - 0.6/1kV(1.8/3kV) BFOU(VFD) - SHF2 Resistance - IEC 60331

    1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
    2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied over the conductors.
    4) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
    5) Application of copper tape.
    6) Frame: *2
    - Tinned copper wire mesh (Code 0)
    - Bronze wire mesh (Code B)
    - Galvanized steel wire mesh (Code C)
    7) Final cover in halogen-free polyolefin compound LSOH (SHF2), black (Code U)

    Identification

    Conductor colours: Black, White, Red
    Earth conductor colours: Green.

    EXTERNAL RECORDING (example): INNOVCABLE 01 BFOU - VFD 0,6/1(1,8/3)kV 3X95 + 3×16 mm² FLAME IEC 60331-1 or IEC 60331-2 IEC 60331-21, IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Fire Resistance: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Special cable for motors and frequency inverters / Azimuth motors up to 1 kV. Suitable for voltage peaks of up to 3600V. Shielded cable for fixed installations on ships and offshore units. Can be installed and operated both indoors and outdoors. NEK 606. For environments requiring flame protection in accordance with IEC 60331.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned Copper Conductor can be manufactured in class 2.
    2) Separating tape can be applied before/after the frame.
    3) Operating voltage : 0.6/1kV(1.8/3kV)
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español