Rubber Cables
Rubber covered handles for light and medium duty applications
INNOVCABLE H05RR-F - 500V
- Conductor material: bare copper wires.
- Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
- Vein insulation: CECO™ Special Elastomeric Compound.
- White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
- Twisted in layers.
- Outer jacket: CEAC™ Special elastomeric compound for light duty applications.
- Outer jacket in BLACK, RAL 9005 colour.
- Rated voltage: 300/500V
- Voltage test: 2000V
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Insulation resistance: Min. 20 MΩX Km at 20°C.
- Min. bending radius: as per VDE 0298 part 3
- Fire behaviour: according to IEC 60332-2-1
Identification
INNOVCABLE - H05RR-F n x mm² 300/500V OF:XXXX/YEAR
Applicable Specifications
Applications
H05RR-F : Rubber electrical cable with light mechanical resistance. Suitable for connections of household appliances and office environments. Suitable for use in dry, damp and wet locations and for outdoor use.
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125° C
Movable Min/max: -30° C / +125° C
Constructive Data
Notes
- Innovcable reserves the right to modify this catalogue without prior notice.
INNOVCABLE H05RN-F - 500V
- Conductor material: bare copper wires.
- Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
- Vein insulation: CECO™ Special Elastomeric Compound.
- White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
- Twisted in layers.
- Outer jacket: CEAC™ Special elastomeric compound for medium resistance applications.
- Outer jacket in BLACK, RAL 9005.
- Rated voltage: 300/500V
- Voltage test: 2000V
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Insulation resistance: Min. 20 MΩX Km at 20°C.
- Min. bending radius: as per VDE 0298 part 3
- Fire behaviour: according to IEC 60332-2-1
Identification
INNOVCABLE - H05RN-F n x mm² 300/500V OF:XXXX/YEAR
Applicable Specifications
Applications
H05RN-F : Rubber electrical cable with medium mechanical resistance. Suitable for connections of electrical appliances and office environments. Suitable for use in dry, damp and wet places and for outdoor use.
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125° C
Movable Min/max: -30° C / +125° C
Constructive Data
Notes
- Innovcable reserves the right to modify this catalogue without prior notice.