Naval Cables - NEK-606/IEC - SHF2 Resistance

Power, control and lighting cables - Flame resistant - SHF2 resistance

    INNOVCABLE Power, Control and Lighting 0.6/1(1.2)kV RFOU, RFBU, RFCU, TFOU, TFBU, TFCU - P1 and P1/P8 - SHF2 Resistance

    1) Conductor made of tinned electrolytic copper wires, soft temper, stranding class 5, according to IEC 60228. *1
    2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
    4) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
    5) Frame: *2
    - Tinned copper wire mesh (Code 0)
    - Bronze wire mesh (Code B)
    - Galvanized steel wire mesh (Code C)
    6) Final cover in halogen-free polyolefin compound LSOH (SHF2), black (Code U)

    Identification

    A-) Number of Conductors (Without Earth G conductor)
    1C: Single conductor - Black or White
    2C: Two conductors - White, Black
    3C: Three conductor - White, Black, Red
    4C: Four conductors - White, Black, Red, Blue
    5C or more: Five conductors or more - Black or White conductors numbered sequentially.

    B-) Number of conductors (with G earth conductor)
    2C +E: Three conductors - White, Black, Green
    3C +E: Four conductors - White, Black, Red, Green
    4C +E: Five conductors - White, Black, Red, Blue, Green
    6C or more: Six or more conductors - Black or white sequentially numbered conductors + green lane

    Engraving on outer cover (example): "year" Innovcable 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Naval cables for fixed installations for power, control and lighting in EX environments (Zone 0, 1 and 2) and secure areas (SHF2).

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned Copper Conductor can be manufactured in class 2.
    2) Tape can be applied before/after the frame.
    3) Operating voltage : 0,6/1(1,2)kV
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE Power, Control and Lighting 0.6/1(1.2)kV RU, TU - P18 - SHF2 Resistance

    1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
    2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
    6) Final coating in halogen-free polyolefin compound LSOH (SHF2), in black color. (Code U)

    Identification

    A-) Number of Conductors (Without Earth G conductor)
    1C: Single conductor - Black or White
    2C: Two conductors - White, Black
    3C: Three conductor - White, Black, Red
    4C: Four conductors - White, Black, Red, Blue
    5C or more: Five conductors or more - Black or White conductors numbered sequentially.

    B-) Number of conductors (with G earth conductor)
    2C +E: Three conductors - White, Black, Green
    3C +E: Four conductors - White, Black, Red, Green
    4C +E: Five conductors - White, Black, Red, Blue, Green
    6C or more: Six or more conductors - Black or white sequentially numbered conductors + green lane

    Engraving on outer cover (example): "year" Innovcable 01 RU 0.6/1KV P18 3 x 2.5 mm2 IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Marine cables for fixed installations for power, control and lighting in EX environments (Zone 0, 1 and 2) and secure areas (SHF2). Cables are double-layered, single cables are used as battery cables.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned copper conductor can be manufactured in class 2.
    2) Operating voltage: 0,6/1(1,2)kV
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE Power 0.6/1kV UX, RX, TX - P15 - SHF2 Resistance

    RX1
    RX2

    1) Conductor formed by electrolytic tinned copper wires, soft temper, class 5 stranding, according to IEC 60228. *1
    2) Conductor insulation in special halogen-free compound LSOH
    - Code R - HEPR/EPR - according to IEC 60092-351.
    - Code T - XLPE - according to IEC 60092-351.
    - Code U - SHF2 - according to IEC 60092-359.
    3-) Green outer cover.

    Identification

    Example: "year" INNOVCABLE UX 1000V P15 1x 95 mm² IEC 332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Insulated conductor for earthing services. In accordance with NEK TS 606: 2009.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned Copper Conductor can be manufactured in Class 2.
    2) Polyester tape can be used on the conductor.
    3) Operating voltage: 0,6/1kV
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE Frequency Inverter - 0.6/1kV(1.8/3kV) RFOU(VFD), TFOU(VFD) - SHF2 Resistance

    1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
    2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
    3) Insulated conductors cabled together, non-hygroscopic and flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
    4) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
    5) Application of copper tape.
    6) Frame: *2
    - Tinned copper wire mesh (Code 0)
    - Bronze wire mesh (Code B)
    - Galvanized steel wire mesh (Code C)
    7) Final cover in halogen-free polyolefin compound LSOH (SHF2), black (Code U)

    Identification

    Conductor colours: Black, White, Red
    Earth conductor colours: Green.

    OUTDOOR RECORDING: INNOVCABLE 01 RFOU - VFD 0,6/1(1,8/3)kV 3X95 + 3×16 mm² IEC 60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-353
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Retardant: IEC 60332-1 and IEC 60332-3 Category A
    Halogen content: IEC 60754-1, 0.5%.
    Cold / impact bending : CSA 22.2 No.03 (-40°C/-35°C)
    NEK-606
    Luminosity transmission in smoke: IEC 61034, 60% >.

    Applications

    Special cable for motors and frequency inverters / Azimuth motors up to 1 kV. Suitable for voltage peaks of up to 3600V. Shielded cable for fixed installations on ships and offshore units. Can be installed and operated both indoors and outdoors.

    Maximum Conductor Temperature

    90°C

    Notes

    1) Tinned Copper Conductor can be manufactured in class 2.
    2) Separating tape may be applied before/after the frame.
    3) Operating voltage: 0.6/1kV(1.8/3kV)
    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español