Cables for cranes, gantries, bridge cranes, festoons and lifts

Constant movement in lifts

    INNOVCABLE LIFT K2YSTFU11Y LSZH

    - Conductor material: bare copper wires
    - Conductor class: according to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: CECO™ Special elastomeric compound.
    -Vein colours: black or white veins numbered sequentially with or without green earth (G).
    - Twisted in pairs. Conductors twisted in layers.
    - Outer layer: special PUR for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol
    - Outer layer in black, RAL 9005.
    - Rated voltage: 0.5mm² 300V; > 1.0mm² 300/500V.
    - Bending Radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    - Fire behaviour: according to IEC 60332-2 self-extinguishing and flame retardant.

    Special features:
    - K2YSTFU11Y: shielded elements as pairs
    - K2YSTFU11Y 20 G 1 + 3 X (2 X 0.5)C: with steel supporting element

    Identification

    INNOVCABLE LIFT K2YSTFU11Y n (G) X mm² 300/500V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0282
    IEC 60332-2

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) with or without textile support element, with medium mechanical resistance. It has electromagnetic protection through special shielding (see special features). The special extrusion technology, the torsion applied, as well as the material used, allow a longer life and durability in continuous movement. Self-extinguishing and flame retardant. Resistant to oil, grease, lubricants, coolants, gasoline and alcohol. Silicone free during production. Halogen and toxic gas free.

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT K12YSTCU11Y LSZH

    - Conductor material: bare copper wires
    - Conductor class: according to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: CECO™ Special elastomeric compound.
    -Vein colours: black or white veins numbered sequentially with or without green earth (G).
    - Twisted in pairs. Conductors twisted in layers.
    - Outer layer: special PUR for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol
    - Outer layer in black, RAL 9005.
    - Rated voltage: 0.5mm² 300V; > 1.0mm² 300/500V.
    - Bending Radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    - Fire behaviour: according to IEC 60332-2 self-extinguishing and flame retardant.

    Special features:
    K12YSTCU11Y: shielded pairs

    Identification

    INNOVCABLE LIFT K12YSTCU11Y n (G) X mm² 300/500V OF:XXXX/Year.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0282
    IEC 60332-2

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) with or without textile support element, with medium mechanical resistance. It has electromagnetic protection through special shielding (see special features). The special extrusion technology, the torsion applied, as well as the material used, allow a longer life and durability in continuous movement. Self-extinguishing and flame retardant. Resistant to oil, grease, lubricants, coolants, gasoline and alcohol. Silicone free during production. Halogen and toxic gas free.

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT FLGÖU

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: CECO™ Elastomeric Compound Special for mobile applications.
    -Vein colours: black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Layered twisted conductors.
    - Central support element with high tensile strength.
    - Outer jacket: CEAC™ Special Elastomeric Compound for mobile applications resistant to splashing oils, greases, UV, weathering, lubricants, coolants.
    - Outer layer in black, RAL 9005.
    - Rated voltage: 300/500V.
    - Voltage test: 3000V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    - Fire behaviour: according to IEC 60332-1 self-extinguishing and flame retardant.

    Identification

    INNOVCABLE LIFT FLGOU n(G) X mm² 300/500V OF:XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-1

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) and especially for electric lifting platforms, construction sites. Central support element with high tensile strength. Excellent glazing time. Self-extinguishing and flame retardant. Resistant to splashes of oils, greases, lubricants, coolants, UV resistance and weathering. Non halogen, toxic fume free (LSZH). Silicone free during production.

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT YMHY-KST

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: PVC Special for mobile applications
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central support element made of high tensile strength steel cable.
    - Outer jacket: special PVC for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol, UV and weather resistant.
    - Outer layer in black, RAL 9005.
    - Rated voltage: 300/500V.
    - Voltage test: 2000V
    - Bending radius: Fixed use: 15 x d / Mobile use: 8 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    Fire behaviour: according to IEC 60332-1 anti-flame and flame retardant.

    Identification

    INNOVCABLE LIFT YMHY-KST n(G )X mm² 300/500V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-1

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) and especially for electric lifting platforms. Central support element made of high tensile strength steel cable. Excellent life span. Self-extinguishing and flame retardant. Resistant to oils, greases, lubricants, coolants, gasoline and alcohol.

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT YMHY-KT

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: PVC Special for mobile applications
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central support element made of high tensile strength steel cable.
    - Outer jacket: special PVC for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol
    - Outer cover: black, RAL 9005.
    - Rated voltage: 300/500V.
    - Voltage test: 2000V
    - Bending radius: Fixed use: 15 x d / Mobile use: 8 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    Fire behaviour: according to IEC 60332-1 anti-flame and flame retardant.

    Identification

    INNOVCABLE LIFT YMHY-KT n(G) X mm² 300/500V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-1

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) and especially for electric lifting platforms. Central support element with high tensile strength. Excellent service life. Self-extinguishing and flame retardant. Resistant to oils, greases, lubricants, coolants, petrol and alcohol. Silicone-free during production.

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT YMHYCY-KT

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: PVC Special for mobile applications
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central support element formed by high tensile strength steel cable.
    - Tinned copper braided shielding for electromagnetic YMHYCY-KT (EMI) protection
    - Outer cover: special PVC for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol
    - Outer cover: black, RAL 9005
    - Rated voltage: 300/500V.
    - Voltage test: 2000V
    - Bending radius: Fixed use: 15 x d / Mobile use: 8 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    Fire behaviour: according to IEC 60332-1 anti-flame and flame retardant.

    Identification

    INNOVCABLE LIFT YMHYCY-KT n(G) X mm² 300/500V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-1

    Applications

    Highly flexible control and power cable for lifts or lift systems (LIFT) and especially for electric lifting platforms. Central support element with high tensile strength. Excellent service life. Self-extinguishing and flame retardant. Resistant to oils, greases, lubricants, coolants, petrol and alcohol. Silicone free during production. Shielding for electromagnetic protection YMHYCY-KT (EMI).

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT STCN (EMI)

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: CECO™ Elastomeric Compound Special for mobile applications.
    -Vein colours: black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Layered twisted conductors.
    - Central support element with high tensile strength.
    - Shielding: tinned copper mesh, 85% coverage.
    - Outer jacket: CEAC™ special elastomeric compound for mobile applications resistant to splashing oil, grease, UV, weather, lubricants, coolants, flame retardant.
    - Black outer shell.
    - Rated voltage: 300/500V.
    - Voltage test: 3000V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 6 and IEC 60228 class 6.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    Fire behaviour: according to IEC 60332-2-self-extinguishing and flame retardant.

    Identification

    INNOVCABLE LIFT STCN (EMI) n(G) X mm² 300/500V OF:XXXX/YE.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-2-1

    Applications

    Control and power cable for signal and power transmission, highly flexible for lifts or hoisting systems (LIFT) and in particular electric lifting platforms, construction sites. Central support element with high tensile strength. Suspension height 80 metres. Has protection against electromagnetic interference (EMI). Excellent life span. Self-extinguishing and flame retardant. Resistant to splashing oil, grease, lubricants, coolants, UV resistance and weathering. Non halogen, free of toxic fumes (LSZH). Silicone-free during production.

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE LIFT FYMYTW

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: Thermoplastic Special for mobile applications.
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Layered twisted conductors.
    - Supporting elements formed by steel cables with high tensile strength.
    - Outer jacket: special PVC for mobile applications resistant to oils, greases, lubricants, coolants, petrol and alcohol, UV and weather resistant.
    - Outer layer in black, RAL 9005.
    - Rated voltage: 300/500V.
    - Voltage test: 2000V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km at 20 °C.
    Fire behaviour: according to IEC 60332-1 anti-flame and flame retardant.

    Identification

    INNOVCABLE LIFT FYMYTW n(G) X mm² 300/500V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 9005
    DIN VDE 0250
    DIN EN 60332-1

    Applications

    Highly flexible control and power cable for lifts or lifting systems (LIFT) and in particular electric lifting platforms, lifting cranes and port installations. Supporting elements formed by steel cables with high tensile strength. Does not produce axial torsion. Excellent life span. Self-extinguishing and flame retardant. Resistant to oils, grease, lubricants, coolants, gasoline and alcohol.

    Maximum Conductor Temperature

    Min/max: -30° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español