Cables for cranes, gantries, bridge cranes, festoons and lifts

Cables for winders, festoons and conveyor systems

    INNOVCABLE REELFLEX (SMK) (N)SHTÖU-J

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Elastomeric Compound Special for mobile use.
    -Vein colours: black or white veins numbered sequentially with or without green earth.
    - Conductors twisted in layers.
    - Aramid central element.
    - Inner layer: CECO™ Special Elastomeric Compound for mobile use in black colour.
    - Textile fabric between inner and outer cover.
    - Outer layer: CEAC™ Special Elastomeric Compound for mobile applications resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, splashes of oils, greases, lubricants, UV resistance, ozone and weathering.
    - External cover in black or yellow.
    - Rated voltage: 0.6/1KV.
    - Test voltage: 2500V
    - Bending radius: according to VDE 0298 part 3.
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km at 20°C.
    Fire behaviour: according to IEC 60332-2-1

    Identification

    INNOVCABLE REELFLEX(SMK) (N)SHTÖU-J n (G) X mm² 0,6/1KV OF:XXXX/YE.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0298 part 3
    DIN EN 60332-2-1
    DIN VDE 0250
    DIN 0281

    Applications

    Halogen-free cable for winders / reels requiring high mechanical stress resistance, highly flexible for lifts or hoisting systems, festoon systems, conveyor installations, vertical spreaders, underground and surface mining, among others. Excellent life time and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, splashing oils, greases, lubricants, UV resistance, ozone and weathering. Free of silicone during production. Used for speeds up to 180 m/min. Textile tape between inner and outer layer. Aramid centre element. Tensile strength max. 30 N/mm².

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE REELFLEX PUR-HF

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: INNOVLON special compound
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Layered twisted conductors.
    - Central textile element.
    - Inner jacket: PUR special for mobile use.
    - Textile fabric between inner and outer sleeve.
    - Outer jacket: PUR special for mobile applications, resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering.
    - Black outer cover.
    - Rated voltage: 0,6/1KV.
    - Test voltage: 2500V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km at 20°C.

    Identification

    INNOVCABLE REELFLEX PUR-HF n (G) X mm² 0,6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0293
    DIN EN 60332-1 (optional) see notes.
    DIN VDE 0250

    Applications

    Halogen-free cable for heavy-duty winders (vertical and horizontal), highly flexible for lifts or lifting systems, conveyor installations, mobile motors, railway engines and agricultural and construction site devices. Excellent life time and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering. Reduced diameter and weight compared to other cables. Used for speeds up to 180 m/min. Permanent tensile load without the supporting element max. 25 N/mm². Can be used up to 50 m deep in water.

    Maximum Conductor Temperature

    Min/max: -40° C / +90° C

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
    - On request we can produce PUR AC (flame retardant) cables with fire performance: according to IEC 60332-1

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE REELFLEX PUR-HF SCATTER

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: INNOVLON special compound
    -Seam colours: black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Aramid core element.
    - Inner jacket: PUR special for mobile use.
    - Textile fabric between inner and outer sleeve.
    - Outer jacket: PUR special for mobile applications, resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering.
    - Black outer cover.
    - Rated voltage: 0,6/1KV.
    - Test voltage: 4000V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km at 20°C.

    Identification

    INNOVCABLE REELFLEX PUR-HF SCATTER n (G) X mm² 0,6/1Kv OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0293
    DIN EN 60332-1 (optional) see notes.
    DIN VDE 0250

    Applications

    Halogen-free cable for heavy-duty winders (vertical and horizontal), highly flexible for lifts or lifting systems, conveyor installations, vertical spreaders, mobile engines, railway engines and agricultural and yard devices. Excellent life time and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, low temperature flexibility, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering. Reduced diameter and weight compared to other cables. Used for speeds up to 240 m/min, vertical 180 m/min. Textile fabric between inner and outer sheath. Permanent tensile load without the supporting element max. 25 N/mm². Can be used up to 50 m deep in water.

    Maximum Conductor Temperature

    Min/max: -40° C / +90° C

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
    - On request we can produce PUR AC (flame retardant) cables with fire performance: according to IEC 60332-1

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE REELFLEX (K)NSHTÖU-J / (N)SHTÖU-J

    - Conductor material: bare copper wire
    - Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Special Elastomeric Compound for mobile use.
    - Vein colors: sequentially numbered black or white veins with or without ground green (G) according to VDE 0293.
    - Support elements: Textile fiber
    - Conductors twisted in layers.
    - Inner cover: CECO™ Special Elastomeric Compound for mobile use.
    - Anti-twist mesh: Wide polyester mesh between inner and outer cover.
    - Outer cover: CECO™ Special Elastomeric Compound for mobile applications; resistant to hydrolysis, oxidation, heat, low-temperature flexibility, abrasion, oil, grease and lubricant splashes, UV, ozone and weather resistance.
    - Black outer cover.
    - Nominal voltage: 0.6/1KV.
    - Voltage test: 2500V
    - Bend radius: in accordance with VDE 0298 part 3.
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km at 20°C.

    Identification

    INNOVCABLE REELFLEX (K)NSHTÖU-J / (N)SHTÖU-J n (G) X mm² 0,6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0298 part 3
    VDE 0293
    DIN VDE 0250

    Applications

    Halogen-free cable for winders, where tensile strength and directional strength are required. For industrial and commercial use, in civil and agricultural works among other segments. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone and weathering. Free of silicone during production. Used for speeds up to 120 m/min. Textile fabric between inner and outer layer. Maximum tensile strength 20 N/mm².

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FESTOONCABLE (N) GRDGCGÖU (C)-FC (EMV)

    - Conductor material: Tinned copper wire.
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
    - Vein insulation: CECO™ Special Elastomeric Compound.
    -Vein colours: coloured veins with or without green earth (G).
    - Conductors twisted in layers.
    - Inner jacket: CECO™ Special Elastomeric Compound for mobile applications.
    - Shielding: Tinned Copper Mesh with 80% coverage.
    - Outer jacket: CEAC™ Elastomeric Compound Special for mobile applications; resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oil, grease and lubricants, UV resistance, ozone and weathering.
    - External cover in black.
    - Rated voltage: 0.6/1KV.
    - Test voltage: 2500V
    - Bending radius: according to VDE 0298 part 3.
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    Flame behaviour: flameproof according to IEC 60332-2-1

    Identification

    INNOVCABLE FESTOONCABLE (N) GRDGCGÖU (C)-FC (EMV) n (G) X mm² 0.6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0298 part 3
    DIN EN 60332-2-1
    DIN VDE 0250

    Applications

    Halogen-free power and control cables with very high mechanical requirements, which are often stranded. It is protected against electromagnetic interference (EMI). For use in lifting systems, overhead cranes, trolleys, festoons, moving machine parts, conveyor installations. Excellent lifetime and mechanical stress resistance, no data transmission failure. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone, bad weather, anti-flame. Free of silicone during production.

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FESTOONCABLE (N) GRDGÖU

    - Conductor material: tinned copper wire.
    - Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Special Elastomeric Compound.
    -Vein colors: sequentially numbered black or white veins with or without ground green (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Shielding (only applied to bus cables when required in the product configuration): Individually shielded bus cables (approx. 60% coverage) or shielded twisted pairs (approx. 80% coverage).
    - Inner jacket: CECO™ Special Elastomeric Compound for mobile applications.
    - Outer jacket: CEAC™ Special Elastomeric Compound for mobile applications, resistant to hydrolysis, oxidation, heat, low-temperature flexibility, abrasion, oil, grease and lubricant splashes, UV, ozone and weather resistance.
    - Black outer cover.
    - Nominal voltage: 0.6/1KV.
    - Voltage test: 2500V
    - Bend radius: in accordance with VDE 0298 part 3.
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Fire performance: flameproof in accordance with IEC 60332-2-1.

    Identification

    INNOVCABLE FESTOONCABLE (N) GRDGÖU n (G) X mm² 0.6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    VDE 0298 part 3
    DIN EN 60332-2-1
    VDE 0293

    Applications

    Halogen-free power and control cables with very high mechanical requirements, which are often stranded. Some designs are protected against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving machine parts, conveyor installations, baskets. Excellent life span and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashing oils, greases and lubricants, UV resistance, ozone, weathering and flame retardant. Free of silicone during production.

    Maximum Conductor Temperature

    Min/max: -40° C / +130° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FESTOONCABLE-C-PUR-HF

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: INNOVLON special compound
    -Seam colours: black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central textile element.
    - Inner jacket: PUR special for mobile use.
    - Polyester tape + tinned copper braid, 85% coverage.
    - Outer jacket: PUR special for mobile applications; resistant to hydrolysis, oxidation, heat, abrasion, oils, grease, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering, flexible at low temperature.
    - Black outer cover.
    - Rated voltage: 0,6/1KV.
    - Test voltage: 2500 V
    - Bending radius: Fixed use: 12 x d / Mobile use: 7.5 x d
    - Conductor resistance: According to VDE 0295 class 5 and IEC 60228 class 5

    Identification

    INNOVCABLE-FESTOONCABLE-C-PUR-HF n (G) X mm² 0.6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN EN 60332-2-1 (optional) see notes.
    DIN VDE 0250
    VDE 0293

    Applications

    Halogen-free power and control cables with very high mechanical requirements, which are often stranded. It is protected against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving machine parts, conveyor installations. Excellent life span and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, low temperature flex, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering. Used for speeds up to 240 m/min. Permanent tensile load without load-bearing element max. 25 N/mm². Can be applied for use in water up to a depth of 50 m.
    - Also available with shielded pairs. (see table).

    Maximum Conductor Temperature

    Min/max: -40° C / +90° C

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to modify this catalogue without prior notice.
    - On request we can produce PUR AC (flame retardant) cables with fire performance: according to IEC 60332-2-1

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FESTOONCABLE PUR-HF

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: INNOVLON special compound
    -Vein colours: Black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central textile element.
    - Outer jacket: PUR special for mobile applications; resistant to hydrolysis, oxidation, heat, low temperature flexibility, impacts, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV, ozone and weathering.
    - Black outer cover.
    - Rated voltage: 0.6/1KV.
    - Test voltage: 2.500V
    - Bending radius: Fixed use: 12 x d / Mobile use: 6 x d
    - Conductor resistance: According to VDE 0295 class 5 and IEC 60228 class 5.

    Identification

    INNOVCABLE FESTOONCABLE PUR-HF n(G) X mm² 0.6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN EN 60332-2-1 (optional) see notes.
    DIN VDE 0250
    VDE 0293

    Applications

    Halogen-free power and control cables with very high mechanical requirements, which are often stranded. For use in lifting systems, trolleys, festoons, moving machine parts, conveyor installations. Excellent life span and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, low temperature flex, abrasion, oils, greases, lubricants, coolants, gasoline, paraffin, UV resistance, ozone and weathering. Used for speeds up to 240 m/min. Permanent tensile load without load-bearing element max. 25 N/mm². Can be applied for use in water up to a depth of 50 m.

    Maximum Conductor Temperature

    Min/max: -40° C / +90° C

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
    - On request we can produce PUR AC (flame retardant) cables with fire performance: according to IEC 60332-2-1

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FESTOONCABLE-C-PVC-HF

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: INNOVLON special compound
    -Seam colours: black or white sequentially numbered veins with or without green earth (G) according to VDE 0293.
    - Conductors twisted in layers.
    - Central textile element.
    - Inner jacket: special PVC for mobile use.
    - Polyester tape + tinned copper braid 85% coverage.
    - Outer jacket: special PVC for mobile applications, oil, grease, lubricant, UV, ozone and weather resistant.
    - Black outer cover.
    - Rated voltage: 0,6/1KV
    - Test voltage: 2500 V
    - Bending radius: Fixed use: 12 x d / Mobile use: 7.5 x d
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    Burning behaviour: According to IEC 60332-1-2

    Identification

    INNOVCABLE-FESTOONCABLE-C-PVC-HF n (G) X mm² 0.6/1KV OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN EN 60332-1-2
    DIN VDE 0250
    VDE 0293

    Applications

    Power and control cables that demand high demands and are often stranded. It is protected against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving machine parts, conveyor installations. Good life span and resistance to mechanical stress, used in low winding systems Resistant to oils, greases, lubricants, UV resistance, ozone and weathering. Silicone-free during production. Used for speeds up to 240 m/min. Permanent tensile load without load-bearing element max. 25 N/mm².
    - Also available with shielded pairs. (see table).

    Maximum Conductor Temperature

    Moving - Min/max: -20° C / +70° C
    Stationary use - Min/max: -5° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español