Marine Cables - IEC Standard
Power naval cables
INNOVCABLE INNOVSHORE POWER TINY 1 conductor 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,4
2) Insulation in special halogen-free olefinic compound LSOH - (SHF1). *2,5
Conductor voltage: 0.6/1KV
Identification
External Engraving:
INNOVCABLE INNOVSHORE POWER TINY __mm² 0.6/1KV 90°C OF: XXXX/YEAR
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, connection of machinery, among other environments. INNOVSHORE POWER TINY 0,6/1KV cables offer maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under anti-flame fire conditions, not producing toxic and corrosive gases. All products exceed the specifications of the indicated IEC's.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned Copper Conductor can be manufactured in class 2.
2) Identification and colours: Nomenclature to be added at the end of the code according to the colours: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
Other colours can be manufactured on request.
3) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
4) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
5) Insulation material:
SE
SHF2
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER TINY 1 conductor 0.15/0.25KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,4
2) Insulation in special halogen-free ole olefinic compound LSOH - (SHF1). *2,5
Conductor voltage: 0,15/0,25KV
Identification
External Engraving:
INNOVCABLE INNOVSHORE POWER TINY __mm² 0.15/0.25KV 90°C OF: XXXX/YEAR
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, connection of machinery, among other environments. INNOVSHORE POWER TINY 0,15/0,25KV cables offer maximum resistance to chemical products, humidity and UV rays. Not halogenated and with improvement under anti-flame fire conditions, not producing toxic and corrosive gases. All products exceed the specifications of the indicated IEC's.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned Copper Conductor can be manufactured in class 2.
2) Identification and colours: Nomenclature to be added at the end of the code according to the colours: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
Other colours can be manufactured on request.
3) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
4) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
5) Insulation material:
SE
SHF2
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER 1 Conductor 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,6
2) Insulation in special halogen-free compound LSOH (HF-90).*3
3) Covering in halogen-free polyolefin compound LSOH (SHF1).*2,4
Identification
External Engraving:
INNOVCABLE INNOVSHORE POWER __mm² 0.6/1KV 90°C OF: XXXX/YEAR
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, connection of machinery, among other environments. INNOVSHORE POWER 0,6/1KV cables offer maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic and corrosive gases. They exceed the specifications of the indicated IEC's.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours upon request.
3) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
4) Material of the intermediate layer and the cover:
ST2
SE
SHF2
5) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
6) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER Multicore 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
2) Conductor insulation in special halogen-free compound LSOH (HF-90).
3) Final covering in halogen-free polyolefin compound LSOH (SHF1), in grey colour.*2,5
Identification
External engraving:
INNOVSHORE POWER CABLE Multi-conductor __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.
Colours of conductor insulation :
2 conductors: black and white.
3 conductors: black, white and red.
4 conductors: black, white, red and blue.
5 conductors: black, white, red, blue and grey.
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, connection of machinery, among others in industrial environments in general. INNOVSHORE POWER Multicore 0,6/1KV cables offer maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
*We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours on request.
3) Different sections and number of veins.
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER REINFORCED ATA/ATC/ATS/AFC/AFA - BTC/BTS 0,6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.* 1,7
2) Conductor insulation of special halogen-free compound LSOH (HF-90). *4
3) Shielding in braided bare copper wire (BTC) or tinned copper (BTS).*8
4) Inner jacket in halogen-free polyolefin compound LSOH (SHF1).*5
5) Frame: braided galvanized steel wire (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlapping. *9
6) Final covering in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5
Identification
External Recording:
INNOVSHORE POWER ARMED CABLE ATA/ATC/ATS/AFC/AFA - BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.
Colours of conductor insulation :
2 conductors: black and white.
3 conductors: black, white and red.
4 conductors: black, white, red and blue.
5 conductors: black, white, red, blue and grey.
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
Armoured cable provides protection where required. The braided shielding offers excellent protection against electromagnetic interference.
They are used in fixed installations, in trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATA/ATC/ATS/AFC/AFA - BTC/BTS 0,6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours on request.
3) Different sections and amount of veins, up to:
- 71 x 0,50mm² / 71 x 2,50mm²
- 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
- 42 x 6,00mm²
- 20 x 10,0mm²
4) Insulation material of the veins:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of shielding:
BTC - Braided shielding of bare copper wires
BTS - Tinned copper braided shielding
9) Types of shielding:
ATA - Braided armour of galvanized steel wires
ATS - Tinned copper braid shield
ATC - Bare copper braid frame
AFC - Copper Tape Armour
AFA - Galvanized steel tape frame
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER ARMED ATA/ATC/ATS 1 Conductor 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,6
2) Insulation in special halogen-free compound LSOH (HF-90)*3
3) Armature: braided galvanized steel wire (ATA), bare copper (ATC) or tinned copper (ATS) with coverage >90%.*7
4) LSOH halogen-free polyolefin compound (SHF1) cover.*2,4
Identification
External Recording:
INNOVCABLE INNOVSHORE POWER ARMED ATA/ATC/ATS __mm² 0.6/1KV 90°C OF: XXXX/YEAR
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
Reinforced cable provides protection where required.
They are used in fixed installations, trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. The INNOVSHORE POWER ARMED ATA/ATC/ATS 1 Conductor 0.6/1KV cables offer maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
Other colours can be manufactured on request.
3) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
4) Material of the intermediate layer and the cover:
ST2
SE
SHF2
5) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
6) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
7) Types of Armatures:
ATA - Galvanized steel wire braided frame
ATS - Tinned copper braid frame
ATC - Bare copper braid frame
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER ARMED ATC/ATS Multicore 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,7
2) Conductor insulation in special halogen-free compound LSOH (HF-90).*4
3) Crimping or extruded filling.
4) Armature: Stranded bare copper (ATC) or tinned (ATS) wires with coverage >90%.*8
5) Final covering in LSOH halogen-free polyolefin compound (SHF1), in grey colour.*2,5
Identification
External Tape:
INNOVSHORE POWER ARMED ATC/ATS CABLE __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.
Colours of conductor insulation :
2 conductors: black and white.
3 conductors: black, white and red.
4 conductors: black, white, red and blue.
5 conductors: black, white, red, blue and grey.
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
Reinforced cable provides protection where required.
They are used in fixed installations, trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED ATC/ATS Multicore 0.6/1KV Cable offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours on request.
3) Different sections and number of veins.
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATS - Tinned copper wire braided frame
ATC - Bare copper braid frame
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER BLINDED BTC/BTS 1 Conductor 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,6
2) Insulation in special halogen-free compound LSOH (HF-90)*3
3) Shielding: Bare copper braid (BTC) or tinned copper braid (BTS) with coverage >90%.*7
4) LSOH halogen free polyolefin compound (SHF1) cover.*2,4
Identification
External Engraving:
INNOVCABLE INNOVSHORE POWER BLINDED BTC/BTS __mm² 0.6/1KV 90°C OF: XXXX/YEAR.
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
The good quality of the copper shielding reduces electromagnetic interference and electrical interference in electronic installations.
They are used in fixed installations, in trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, machine connection, among other environments. INNOVSHORE POWER CABLE BTC/BTS 1 Conductor 0,6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and with improvement under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
Other colours can be manufactured on request.
3) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
4) Material of the intermediate layer and the cover:
ST2
SE
SHF2
5) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
6) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
7) Types of Shielding:
BTS - Tinned copper braided shield
BTC - Braided shielding of bare copper wires
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER BLINDED BTC/BTS multicore 0.6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,7
2) Conductor insulation in special halogen-free compound LSOH (HF-90). *4
3-) Fitting or extruded filling.
4-) Shielding: Braided bare copper (BTC) or tinned copper (BTS) wires with coverage >90%.*8
5) Final covering in polyolefin compound halogen-free LSOH (SHF1), in gray colour.*2,5
Identification
External Recording:
INNOVCABLE INNOVSHORE POWER BLINDED BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR
Colours of conductor insulation :
2 conductors: black and white.
3 conductors: black, white and red.
4 conductors: black, white, red and blue.
5 conductors: black, white, red, blue and grey.
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
The good quality of the copper shielding reduces electromagnetic interference and electrical interference in electronic installations.
They are used in fixed installations, in trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, machine connection, among other environments. The INNOVSHORE POWER CABLE BTC/BTS Multi-Conductor 0,6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds specifications of IEC's indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours on request.
3) Different sections and number of veins.
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of shielding:
BTS - Braid of tinned copper wires
BTC - Bare copper braid
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE POWER REINFORCED ATA/AFC/AFA 0,6/1KV
1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. *1,7
2) Special halogen free compound LSOH (HF-90).
3) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
4) Frame: Galvanized steel wire braid (ATA) with coverage >90%, copper tape (AFC) or steel tape (AFA) applied with overlap. *8
5) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey in colour.*2,5
Identification
External recording:
INNOVSHORE POWER ATA/AFC/AFA CABLE __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.
Colours of conductor insulation :
2 conductors: black and white.
3 conductors: black, white and red.
4 conductors: black, white, red and blue.
5 conductors: black, white, red, blue and grey.
Multicore: > 5 conductors - white or black veins numbered sequentially.*3
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry.
Reinforced cable provides protection where required.
They are used in fixed installations, trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATA/AFC/AFA 0.6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non halogenous and with improvement under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned copper conductor can be manufactured in class 2.
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours upon request.
3-) Other dimensions: from 1,5mm² to 70,0mm² (also in AWG)
Other formations up to 71 conductors (consult maximum per gauge).
4) Vein insulation material:
EPR - 90 ºC
HEPR - 90 ºC
XLPE - 90 ºC
5) Material of the intermediate layer and the cover:
ST2
SE
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
8) Types of armatures:
ATA - Galvanized steel wire braid frame
AFC - Copper tape frame
AFA - Galvanized steel tape frame
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVSHORE HIGH POWER SHIELDED/ARMOURED 3,6/6KV (7,2KV)
- Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding.
- Semiconductor tape extruded onto the conductor.
- Insulation in thermosetting compound based on halogen-free ethylene-propylene rubber (HF-EPR).
- Semiconductor tape extruded over insulation.
- Metal shielding formed by tinned copper wires.
- Inner layer in halogen-free polyolefin compound.
- Tinned copper wire braid (for unipolar cables up to 95,0mm²) and galvanized steel tape (for unipolar cables over 95,0mm² and multi-core cables).
- Cover in black halogen-free polyolefin compound (SHF1).
Identification
External Recording:
INNOVSHORE HIGH POWER CABLE BTS/ATS or AFA __ x __mm² 3,6/6KV 90°C OF: XXXX/YEAR.
Colours of conductor insulation:
1 conductor: natural colour insulation.
3 conductors: coloured (white, blue and red)
Applicable Specifications
Applications
Built and designed for the demanding environment of offshore drilling and the marine industry in medium voltage applications.
Reinforced cable provides protection where required.
They are used in fixed installations, trays, ducts, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. The INNOVSHORE HIGH POWER BTS/ATS or AFA 3,6/6KV CABLE offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.
Maximum Conductor Temperature
CONTINUOUS DUTY: 90°C - IEC 60092-360
SHORT CIRCUIT: 250°C
Notes
* We manufacture with other configurations:
1) Tinned Copper Conductor can be manufactured in class 2 (on request).
2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
We can manufacture other colours upon request.
4) Vein insulation material:
XLPE - 90 ºC
5) Cover and intermediate layer material:
ST2
SHF2
6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
7) Nomenclature to be added at the end of the code according to the conductor type:
Bare copper conductor - CN
Tinned copper conductor - SN
**Innovcable reserves the right to modify this catalogue without prior notice.