Marine Cables - IEC Standard

IEC 60331 fire resistant marine cables

    INNOVCABLE CONTROL/POWER - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - 1 conductor - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation in mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey colour.*2,5

    Identification

    External engraving:
    INNOVCABLE INNOVSHORE FIRE RESISTANT XLPE/SHF1 __mm² 0.6/1KV 90°C OF: XXXX/ANO IEC 60092/60331

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT power and control cable 0.6 / 1 kV with special properties for non-armoured electrical installations, for use on board ships and offshore units, in all fixed installation locations. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 °C).

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 500mm² (also in AWG)
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL/POWER - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - multicore - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation in mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey colour.*2,5

    Identification

    External Engraving:
    INNOVCABLE INNOVSHORE FIRE RESISTANT XLPE/SHF1 __mm² 0,6/1KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Conductor insulation colours :
    2 conductors: black and white or sequentially numbered white or black veins.
    3 conductors: black, white and red or sequentially numbered white or black veins.
    4-conductors: black, white red and blue or sequentially numbered white or black veins.
    5-conductor: black, white red, blue and grey or sequentially numbered white or black veins.
    Multicore: > 5 conductors - sequentially numbered white or black veins.

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT power and control cable 0.6 / 1 kV with special properties for non-armoured electrical installations, for use on board ships and offshore units, in all fixed installation locations. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 °C).

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 70,0mm² (also in AWG)
    Other formations up to 71 conductors (consult maximum per gauge).
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL/POWER LOCKED BTC/BTS - FIRE RESISTANT - MICA TAPE/HEPR/SHF1 - 1 conductor - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation is made of mica tape and special halogen-free compound LSOH (HEPR).*4
    3) Shielding: Bare copper braid (BTC), tinned copper (BTS) with coverage >90%. *8
    4) Final covering in LSOH halogen free polyolefin compound (SHF1), grey colour.*2,5

    Identification

    External recording:
    INNOVCABLE INNOVSHORE FIRE RESISTANT BTC/BTS HEPR/SHF1__mm² 0.6/1KV 90°C OF: XXXX/ANO IEC 60092/60331

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT FIRE COVERED cable for power and control 0.6 / 1 kV with special properties for electrical installations, for use on board ships and offshore units, in all fixed installation locations. The shielding provides protection against electromagnetic interference as standard. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C)

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 500mm² (also in AWG)
    4) Vein insulation material:
    EPR - 90 ºC
    HF90 - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of Shielding:
    BTS - Tinned copper wire braid frame
    BTC - Braided frame of bare copper wire

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL/POWER LOCKED BTC/BTS - FIRE RESISTANT - MICA TAPE/HEPR/SHF1 - multicore - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation is made of mica tape and special halogen-free compound LSOH (HEPR).*4
    3) Helically applied polyester tape or extruded wire strand.
    4) Shielding: Braided bare copper wire (BTC), tinned copper (BTS) with coverage >90%. *8
    5) Final covering: LSOH (SHF1) halogen free polyolefin compound, grey colour.*2,5

    Identification

    External recording:
    INNOVCABLE INNOVSHORE FIRE RESISTANT BTC/BTS HEPR/SHF1 __X__mm² 0.6/1KV 90°C OF: XXXX/ANO IEC 60092/60331

    Colours of conductor insulation : *3
    2 conductors: black and white or sequentially numbered white or black veins.
    3 conductors: black, white and red or sequentially numbered white or black veins.
    4-conductors: black, white red and blue or sequentially numbered white or black veins.
    5-conductor: black, white red, blue and grey or sequentially numbered white or black veins.
    Multicore: > 5 conductors - sequentially numbered white or black veins.

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT FIRE COVERED cable for power and control 0.6 / 1 kV with special properties for electrical installations, for use on board ships and offshore units, in all fixed installation locations. The shielding provides protection against electromagnetic interference as standard. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 70,0mm² (also in AWG)
    Other formations up to 71 conductors (consult maximum per gauge).
    4) Vein insulation material:
    EPR - 90 ºC
    HF90 - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of Shielding:
    BTS - Tinned copper wire braid frame
    BTC - Braided frame of bare copper wire

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL/POWER FIRE RESISTANT ATA/ATC/ATS/AFC/AFA - MICA TAPE/XLPE/SHF1 - 1 conductor - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).
    3) Armature: braided galvanised steel wire (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlapping. *
    4) Final covering in halogen-free polyolefin compound LSOH (SHF1), in grey colour.

    Identification

    External Engraving:
    INNOVCABLE INNOVSHORE FIRE RESISTANT ATA/ATC/ATS/AFC/AFA XLPE/SHF1 __mm² 0.6/1KV 90°C OF: XXXX/ANO IEC 60092/60331

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT ARMED cable for power and control 0.6 / 1 kV with special properties for electrical installations, for use on board ships and offshore units, in all fixed installation locations. The Armature provides protection where required as standard. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 500mm² (also in AWG)
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    8) Tinned copper conductor - SN
    9) Types of armatures:
    ATA - Galvanized steel wire braided frame
    ATS - Tinned copper braid frame
    ATC - Bare copper wire braid frame
    AFC - Copper Tape Armour
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE CONTROL / POWER ATA/ATC/ATS/AFC/AFA - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - multicore - 0,6/1Kv - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
    4) Frame: braided galvanized steel wire (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlapping. *8
    5) Final covering in LSOH halogen free polyolefin compound (SHF1), in grey colour.*2,5

    Identification

    External Engraving:
    INNOVCABLE INNOVSHORE FIRE RESISTANT ATA/ATC/ATS/AFC/AFA XLPE/SHF1 __X__mm² 0.6/1KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Colours of conductor insulation : *3
    2 conductors: black and white or sequentially numbered white or black veins.
    3 conductors: black, white and red or sequentially numbered white or black veins.
    4-conductors: black, white red and blue or sequentially numbered white or black veins.
    5-conductor: black, white red, blue and grey or sequentially numbered white or black veins.
    Multicore: > 5 conductors - sequentially numbered white or black veins.

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT ARMED cable for power and control 0.6 / 1 kV with special properties for electrical installations, for use on board ships and offshore units, in all fixed installation locations. The Armature provides protection where required as standard. Temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 70,0mm² (also in AWG)
    Other formations up to 71 conductors (consult maximum per gauge).
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braided frame
    ATS - Tinned copper braid frame
    ATC - Bare copper braid frame
    AFC - Copper Tape Armour
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / CONTROL - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - multicore - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation in mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey colour.*2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT XLPE/SHF1 __mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    - Black or white veins numbered sequentially. *3

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION cables 0.15/0.25KV offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours upon request.
    3-) Other dimensions: from 1,5mm² to 2,50mm² (also in AWG).
    Other formations up to 71 conductors (consult maximum per gauge).
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / CONTROL BLINDED BF- FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - Multi Pair/Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Polyester Tape.
    5) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Covering in polyolefin compound halogen free LSOH (SHF1), in grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION BF XLPE/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The shielding offers protection against electromagnetic interference.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE INSTRUMENTATION/CONTROL BF 0,15/0,25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / BLINDED CONTROL BFI - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - Multi Pair/Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Polyester Tape.
    5) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    6) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION BFI XLPE/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The shielding offers protection against electromagnetic interference.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE INSTRUMENTATION/CONTROL BFI 0.15/0.25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / CONTROL ATC/ATS- FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - Multi Pair/Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    5) Polyester Tape.
    6) Frame: bare copper (ATC) or tinned copper (ATS) wire braid with coverage >90%. *8
    7) Halogen-free polyolefin LSOH (SHF1) cover, grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION ATC/ATS XLPE/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs). *3
    black, white, red and green (cables in pairs).
    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The frame provides protection as required by the standard.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION ATC/ATS 0.15/0.25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / CONTROL ATC/ATS- FIRE RESISTANT - MICA TAPE/HEPR/SHF1 - Multi Pair/Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (HEPR).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    5) Polyester Tape.
    6) Frame: bare copper (ATC) or tinned copper (ATS) wire braid with coverage >90%. *8
    7) Halogen-free polyolefin LSOH (SHF1) cover, grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION ATC/ATS HEPR/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in pairs).*3
    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The frame provides protection as required by the standard.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION ATC/ATS HEPR 0.15/0.25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HF90 - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / ARMED CONTROL / ATC/ATS BF- FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - Multi Pair / Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Aluminium-polyester tape collective shield, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Polyester tape.
    6) Armature: braided bare copper (ATC) or tinned copper (ATS) wires with coverage >90%. *8
    7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION ATC/ATS BF XLPE/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The shielding offers protection against electromagnetic interference and the frame provides protection as required by the standard.
    Used on board ships in fixed installations, trays, ducts, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION ATC/ATS BF 0,15/0,25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INSTRUMENTATION / ARMED CONTROL / ATC/ATS BFI - FIRE RESISTANT - MICA TAPE/XLPE/SHF1 - Multi Pair / Triple - 0,15/0,25Kv (300V) - IEC 60331

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Conductor insulation of mica tape and special halogen-free compound LSOH (XLPE).*4
    3) Communication conductor with 0,5mm² section, in LSOH (HEPR) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Polyester tape.
    6) Armature: braided bare copper (ATC) or tinned copper (ATS) wires, coverage >90%. *8
    7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    INNOVCABLE INNOVSHORE FIRE RESISTANT INSTRUMENTATION ATC/ATS BFI XLPE/SHF1 __X__X__mm² 0,15/0,25KV 90°C OF: XXXX/ANO IEC 60092/60331.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376
    Selection and installation of electrical cables: IEC 60092-352
    Meets fire test - circuit integrity - procedures and requirements 0.6/1Kv - IEC 60331-21
    Low Smoke emission: IEC 61034- 1/2
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.

    Applications

    FIRE RESISTANT cable, temperature class 90 °C, flame retardant (IEC 60332-3), low smoke emission, halogen free, low toxicity and fire resistant "FIRE BARRIER" type (IEC 60331, 950 ° C).
    Built and designed for the demanding environment of offshore drilling and the marine industry. The shielding offers protection against electromagnetic interference and the frame provides protection as required by the standard.
    Used on board ships in fixed installations, trays, ducts, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION ATC/ATS BFI 0.15/0.25KV cables offer maximum resistance to chemical products, humidity and UV rays. They exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coat Colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // LJ - Orange
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0.50mm² / 36 x 4 x 2.50mm².
    Also available in AWG.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    HF90 - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.