Marine Cables - IEC Standard

Naval control cables

    INNOVCABLE INNOVSHORE CONTROL 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.*1,7
    2) Conductor insulation in special halogen-free compound LSOH (HF-90). *4
    3) Final covering in halogen free polyolefin compound LSOH (SHF1), in grey colour. *2,5

    Identification

    - External Engraving:
    INNOVCABLE INNOVSHORE CONTROL __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    - White veins numbered sequentially, can be manufactured on customer request with a green track (protective conductor). *3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, connection of machinery, among others in industrial environments in general. INNOVSHORE CONTROLE 0,6/1KV cables offer maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic or corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    *We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, maximum up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE SHIELDED CONTROL BTC/BTS 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation is made of special halogen-free compound LSOH (HF-90). *4
    3) Crimping or extruded filling.
    4) Shielding: Braided bare copper (BTC) or tinned copper (BTS) wires with coverage >90%. *8
    5) Final covering in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5

    Identification

    External recording:
    INNOVSHORE CONTROL BLINDED BTC/BTS CABLE __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Of the conductors - white insulation sequentially numbered. *3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They have excellent protection against electromagnetic interference.
    They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE CONTROL BLINDED BTC/BTS 0,6/1KV CABLE offers maximum resistance to chemical products, humidity and UV rays. Non-halogen and improved under fire conditions, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of shielding:
    BTS - Tinned copper wire braided shield
    BTC - Braided shielding of bare copper wires

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE REINFORCED CONTROL ATC/ATS 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation is made of special halogen-free compound LSOH (HF-90). *4
    3) Crimping or extruded filling.
    4) Armature: Stranded bare copper (ATC) or tinned copper (ATS) wires with coverage >90%. *8
    5) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey colour. *2,5

    Identification

    External recording:
    INNOVSHORE ATC/ATS ARMED CONTROL CABLE __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Of the conductors - white insulation sequentially numbered. *3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Reinforced cable provides protection where it is required.
    They are used in fixed installations, in trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE ATC/ATS ARMED CONTROL CABLE 0.6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATS - Tinned copper wire braided frame
    ATC - Bare copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE REINFORCED CONTROL ATA/AFC/AFA 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. *1,7
    2) Special halogen free compound LSOH (HF-90).
    3) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
    4) Frame: Galvanized steel wire braid (ATA) with coverage >90%, copper tape (AFC) or steel tape (AFA) applied with overlap. *8
    5) Final covering in LSOH halogen-free polyolefin compound (SHF1), grey in colour.*2,5

    Identification

    External recording:
    INNOVSHORE ATA/AFC/AFA CONTROL CABLE __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    The conductors - sequentially numbered white insulation.*3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Reinforced cable provides protection where it is required.
    They are used in fixed installations, in trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE CONTROL CABLE ARMED ATA/AFC/AFA 0.6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    AFC - Copper tape frame
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE CONTROL ARMOURED/SHIELDED ATA/ATC/ATS/AFC/AFA - BF 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.* 1,7
    2) Conductor insulation of special halogen-free compound LSOH (HF-90). *4
    3) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    4) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
    5) Frame: braided galvanised steel wire (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlapping. *8,9
    6) Final covering in LSOH halogen free polyolefin compound (SHF1), in grey colour. *2,5

    Identification

    External recording:
    INNOVSHORE CONTROL ARMED ATA/ATC/ATS/AFC/AFA CABLE - BF __ x __mm² 0,6/1KV 90°C OF: XXXX/ANO.

    The conductors - sequentially numbered white insulation.*3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where it is required. The shielding protects against electromagnetic interference.
    They are used in fixed installations, trays, ducts, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. INNOVSHORE CABO CABO CABLE ARMED/PLUGGED ATA/ATC/ATS/AFC/AFA - BF 0,6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non halogenous and with improvement under fire condition, anti-flame, it does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    ATS - Tinned copper braid frame
    ATC - Bare copper braid frame
    AFC - Copper Tape Armour
    AFA - Galvanized steel strip frame
    9) Dimensions may change according to the frame in copper tape or galvanized steel tape. Please consult.

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE CONTROL ARMOURED/SHIELDED ATA/ATC/ATS/AFC/AFA - BTC/BTS 0,6/1KV

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228.* 1,7
    2) Conductor insulation of special halogen-free compound LSOH (HF-90). *4
    3) Shielding in braided bare copper wire (BTC) or tinned copper (BTS).*8
    4) Inner jacket in halogen-free polyolefin compound LSOH (SHF1).*5
    5) Frame: braided galvanized steel wire (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlapping. *9
    6) Final covering in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5

    Identification

    External Recording:
    INNOVSHORE ATA/ATC/ATS/AFC/AFA CONTROL CABLE - BTC/BTS __ x __mm² 0,6/1KV 90°C OF: XXXX/ANO.

    The conductors - sequentially numbered white insulation.*3

    Applicable Specifications

    Strings: IEC 60228
    Electrical installations in ships - Power cables for 1 kV and 3 kV voltages: IEC 60092-353
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Low Smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where it is required. The braided shielding offers excellent protection against electromagnetic interference.
    They are used in fixed installations, in trays, troughs, conduits, panels, among others. Indicated for use in control circuits, command and signaling, power supply, machine connection, among other environments. INNOVSHORE CABO CABO CABLE ARMED/PLUGGED ATA/ATC/ATS/AFC/AFA - BTC/BTS 0,6/1KV offers maximum resistance to chemical products, humidity and UV rays. Non halogen and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections, colours and amount of veins, up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of shielding:
    BTC - Braided shielding of bare copper wires
    BTS - Tinned copper braided shielding
    9) Types of shielding:
    ATA - Braided armour of galvanized steel wires
    ATS - Tinned copper braid shield
    ATC - Bare copper braid frame
    AFC - Copper Tape Armour
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español