CATHODE CABLES
INNOVDF/HMWPE cables
INNOVCABLE CATHODE CABLE INNOVDF/HMWPE 0,6/1KV
1-) Conductor formed by stranded bare copper wires according to ASTM B-8 (CL. 2) or ASTM B172 (Cl. 5)
2-) Insulation in INNOVDF fluoropolymer extruded on conductor.
3-) Lining: HMWPE of HIGH MOLECULAR WEIGHT in accordance with ASTM D-1248, type 1, class A, category 5, Grades E4 and E5. Tensile strengths JL, J3.
Identification
INNOVCABLE INNOVDF/HMWPE CATHODIC CABLE n (x) or (G) mm² 0,6/1kv OF: XXXX/YEAR
Applicable Specifications
Applications
Cable built with high molecular weight polyethylene. This compound provides excellent performance in its application. Cable can be directly buried, for use in cathodic protection applications such as lead anode wires, pipeline to rectifier connections, cross connection, message test connections, deep well or other situations where resistance to chlorine gas, brackish water, corrosive liquids, extreme underground conditions, etc. is required. The product can also be used for submerged installations in water tanks, marine structures and other similar applications.
INNOVDF insulation provides chemical resistance properties, most importantly, possessing the following characteristics and attributes:
Excellent resistance to fatigue, creep and shear.
Easily can be cross-linked by ionizing radiation after compounding with co-agents.
Chemical resistance to a variety of acids, bases and organic solvents
Excellent fire and smoke performance
Good electrical properties
Excellent weatherability
Low density.
Secondary or outer high molecular weight polyethylene (HMWPE) coating provides abrasion resistance.
Black colour (standard). Other custom colours are available depending on the quantity purchased.
Maximum Conductor Temperature
+150 ° C
Notes
- We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE CATHODE CABLE INNOVDF/HMWPE-HDP 0,6/1KV
1-) Conductor formed by stranded bare copper wires according to ASTM B-8 (CL. 2) or ASTM B172 (Cl. 5)
2-) Insulation: INNOVDF fluoropolymer insulation extruded over the conductor.
3-) Lining: High density polyethylene (HMWPE-HDP) in accordance with ASTM D-1248 (types II, III, IV) Class B & C.
Identification
INNOVCABLE INNOVDF/HMWPE-HDP CATHODIC CABLE n (x) or (G) mm² 0,6/1kv OF: XXXX/YEAR
Applicable Specifications
Applications
This cable provides excellent performance in its application. It can be directly buried, for use in cathodic protection applications such as lead anode wires, pipeline to rectifier connections, cross connection, message test connections, deep well or other situations where resistance to chlorine gas, brackish water, corrosive liquids, extreme underground conditions, etc. is required. The product can also be used for submerged installations in water tanks, marine structures and other similar applications.
INNOVDF insulation provides chemical resistance properties, most importantly, possessing the following characteristics and attributes:
Excellent resistance to fatigue, creep and shear.
Easily can be cross-linked by ionizing radiation after compounding with co-agents.
Chemical resistance to a variety of acids, bases and organic solvents
Excellent fire and smoke performance
Good electrical properties
Excellent weatherability
Low density.
Secondary or outer high density polyethylene (HMWPE-HDP) coating provides abrasion resistance.
Black colour (standard). Other custom colours are available depending on the quantity purchased.
Maximum Conductor Temperature
+150 ° C
Notes
- We can produce on request, several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.