Naval Cables - NEK-606/IEC - SHF2 Resistance
Instrumentation and communication cables - Flame resistant - SHF2 resistance
INNOVCABLE Instrumentation and Communication 150/250(300)V RFOU(c), RFBU(c), RFCU(c), TFOU(c), TFBU(c), TFCU(c) - S2 and S2/S6 - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
5-) Collective shield in aluminized polyester tape + drain wire (Code (c))
6) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
7) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
8) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
9) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RFOU(C) 250V S2/S6 4PAIR 0.75mm2 IEC 60092-376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35deg. C)
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable for fixed installations in Ex - and safe areas. Meets NEK TS 606: 2009 resistance requirement. Meets the cold / cold bend impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 and Annex E at -40°C / -35°C.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V RFOU(i), RFBU(i), RFCU(i), TFOU(i), TFBU(i), TFCU(i) - S1 and S1/S5 - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
7) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
8) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
9) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RFOU(i) 250V S2/S6 4PAIR 0.75mm2 IEC 60092-376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35deg. C)
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable for fixed installations in Ex - and safe areas. Meets the resistance requirement in NEK TS 606:2009. Meets the cold / cold bend impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 and Annex E at -40°C / -35°C.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V RFOU(i&c), RFBU(i&c), RFCU(i&c), TFOU(i&c), TFBU(i&c), TFCU(i&c) - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Collective shield in aluminized polyester tape + drain wire (Code (c))
7) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
8) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
9) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
10) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RFOU(i&c) 250V 4PAIR 0.75mm2 IEC 60092-376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35deg. C)
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cables for fixed installations in Ex - and safe areas. Individually and collectively shielded. Meets NEK TS 606: 2009 resistance requirement. Meets the cold / cold bend impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 and Annex E at -40°C / -35°C.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V RU(i), TU(i), - S11 - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
7) Outer jacket in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable for fixed installations in Ex areas (Zone 2) and safe areas. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V RU(c), TU(c), - S12 - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
5-) Collective shielding in aluminized polyester tape + drain wire (Code (c))
6) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
7) Outer cover in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RU(c) 250V S12 2 pair 0,75 mm2 IEC 60092-376 IEC60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable for fixed installations in Ex areas (Zone 2) and safe areas. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V RU(i&c), TU(i&c), - SHF2 Resistance
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Conductor insulation in special halogen-free compound LSOH - (Code R(HEPR/EPR), T(XLPE)) - according to IEC 60092-351.
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Collective shielding in aluminized polyester tape + drain wire (Code (c))
7) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
8) Outer cover in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "Year" Innovcable 01 RU(i&c) 250V 4PAIR 0.75mm2 IEC 60092-376 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cables for fixed installations in Ex areas (Zone 2) and secure areas. Individually and collectively shielded. Meets the NEK TS 606: 2009 resistance requirement.
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V