Naval Cables - NEK-606/IEC - SHF2 Resistance
Instrumentation and Communication Cables - Fire Resistance IEC 60331 - SHF2 Resistance
INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(c), BFBU(c), BFCU(c) - S4 and S4/S8 - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Pairs or Triples assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
5-) Collective shield in aluminized polyester tape + drain wire (Code (c))
6) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
7) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
8) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
9) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 0, 1 and 2) and safety, emergency and critical systems areas where fire resistance is required by IEC 60331. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(i), BFBU(i), BFCU(i) - S3 and S3/S7 - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Inner jacket made of halogen-free polyolefin compound LSOH - (Code F)
7) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
8) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
9) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 0, 1 and 2) and safety, emergency and critical systems areas where fire resistance is required by IEC 60331. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(i&c), BFBU(i&c), BFCU(i&c) - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Collective shield in aluminized polyester tape + drain wire (Code (c))
7) Inner jacket in halogen-free polyolefin compound LSOH - (Code F)
8) Frame: *2
- Tinned copper wire mesh (Code 0)
- Bronze wire mesh (Code B)
- Galvanized steel wire mesh (Code C)
9) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
10) Outer cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BFOU(i&c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 0, 1 and 2) and safety, emergency and critical systems areas where fire resistance is required by IEC 60331. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned Copper Conductor can be manufactured in class 2.
2) Separating tape may be applied before/after the frame.
3) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V BU(i) - S13 - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Final coating in halogen-free polyolefin compound LSOH (SHF2). (Code U)
7) Outer jacket in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BU(c) 250V S13 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 2) and safety, emergency and critical systems areas where fire resistance is required by IEC 60331. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V BU(c) - S14 - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Pairs or Triples assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
5) Collective shielding in aluminized polyester tape + drain wire (Code (c))
6) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
7) Outer cover in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BU(c) 250V S14 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 2) and safety, emergency and critical systems areas where IEC 60331 fire resistance is required. Meets resistance requirement NEK TS 606:2009
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE Instrumentation and Communication 150/250(300)V BU(i&c) - SHF2 Resistance - IEC 60331
1) Conductor made of tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH - IEC 60331 (Code B)
3) Twisted conductors forming Pairs, Trios or Squares.
4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
5) Pairs or Trios assembled together and identified by sequential numbers, non-hygroscopic flame-retardant filaments can be used in the conductor construction and tapes can be applied to the conductors.
6) Collective shielding in aluminized polyester tape + drain wire (Code (c))
7) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
8) Outer cover in gray (Not Intrinsically Safe) or blue (Intrinsically Safe - IS)
Identification
Conductors in the colours:
Pair: Black - Light Blue
Trio: Black - Light Blue - Brown
Quad: Black - Light Blue - Brown - Grey
Identification on outer jacket (example): "year" INNOVCABLE 01 BU(i&c) 250V 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC 60332-3-22
Applicable Specifications
Applications
Instrumentation, communication, control and alarm cable, for fixed installations in Ex areas (Zone 2) and safety, emergency and critical systems areas where fire resistance is required by IEC 60331. Meets the resistance requirement NEK TS 606:2009.
Maximum Conductor Temperature
90°C
Notes
1) Tinned copper conductor can be manufactured in class 2.
2) Operating voltage: 150/250(300)V
**Innovcable reserves the right to change this catalogue without prior notice.