Flexible Special Control Cables

Harmonized Control Cables

    INNOVCABLE H05VV5-F

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with green earth (G).
    -Twisted in layers.
    - Special PVC outer cover resistant to oils, grease and acids, manufactured in the colour grey RAL 7001.
    - Free from silicone and harmful substances.
    - Rated voltage: 300/500V
    - Test voltage: 3000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE H05VV5-F n (x) or (G) mm² 300/500V OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, fixed and flexible applications without traction, can be applied in dry and wet locations. Can be applied outdoors with UV application. Fireproof and flame retardant according to IEC 60332-1. Resistant to oils, grease and acids. Manufactured free of noxious substances and silicone.

    Maximum Conductor Temperature

    -40° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = no green conductor to earth (OZ).
    - Various other cable options and configurations can be produced on request. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE H05VVC4V5-K

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with green earth (G).
    -Twisted in layers.
    - Protective intermediate layer in special PVC
    - Shielding: shielding of tinned copper wires, 85% coverage.
    - Outer layer in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Test voltage: 3000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use:6 x d
    - Min. bending radius if mobile: 12 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE H05VVC4V5-K n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Anti-flame and flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. Additional mechanical protection through intermediate frame

    Maximum Conductor Temperature

    -40° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = no green conductor to earth (OZ).
    - Various other cable options and configurations can be produced on request. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FG7OH1R

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: HEPR rubber - Quality G7 - White or black veins identified by black or yellow sequentially numbered engraving with or without green earth (G).
    - Twisted in layers.
    - Intermediate protective layer in special PVC or textile filament (Application depends on variables of gauge and number of veins)
    - Shielding: Copper tape
    - Outer layer in special PVC
    - Manufactured in Black.
    - Manufactured free of noxious substances and silicone.
    - Rated voltage: 600/1000V
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 10 MΩ X Km.
    - Min. bending radius fixed use: 8 x d
    - Short circuit temperature: +250°C
    - Flameproof and flame retardant according to IEC 20-22 II - IEC 60332-34, IEC EN 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE FG7OH1R n (x) or (G) mm² 600/1000V OF: XXXX/ANO

    Applicable Specifications

    ERC 20-22II
    UNEL 35377
    IEC 20-37 pt.2 (EN50267)
    ERC 20-13
    CEI 20-35 (EN60332-1)
    ERC 20-52

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed indoor and outdoor applications, can be applied in dry and wet places. It has UV protection (outdoor use). EMC electromagnetic interference shielding. Underground placement is acceptable, even if not shielded.

    Maximum Conductor Temperature

    -25° C / +90° C

    Notes

    G = with 1 green conductor to earth;
    x = no green conductor to earth (OZ).
    - Various other cable options and configurations can be produced on request. Innovcable reserves the right to change this catalogue without prior notice.
    - The dimensional values are fictitious calculations, and Engineering should be consulted to obtain the real calculation.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FG7OH2R

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: HEPR rubber - Quality G7 - White or black veins identified by black or yellow sequentially numbered engraving with or without green earth (G).
    - Twisted in layers.
    - Intermediate protective layer in special PVC or textile filament (Application depends on variables of gauge and number of veins)
    - Shielding: Bare copper mesh
    - Outer layer in special PVC
    - Manufactured in Black.
    - Manufactured free of harmful substances and silicone.
    - Rated voltage: 600/1000V
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 10 MΩ X Km.
    - Min. bending radius fixed use: 8 x d
    - Short circuit temperature: +250°C
    - Flameproof and flame retardant according to IEC 20-22 II - IEC 60332-34, IEC EN 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE FG7OH2R n (x) or (G) mm² 600/1000V OF: XXXX/ANO

    Applicable Specifications

    ERC 20-22II
    UNEL 35377
    IEC 20-37 pt.2 (EN50267)
    ERC 20-13
    CEI 20-35 (EN60332-1)
    ERC 20-52

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed indoor and outdoor applications, can be applied in dry and wet places. It has UV protection (outdoor use). EMC electromagnetic interference shielding. Underground placement is acceptable, even if not shielded.

    Maximum Conductor Temperature

    -25° C / +90° C

    Notes

    G = with 1 green conductor to earth;
    x = no green conductor to earth (OZ).
    - Various other cable options and configurations can be produced on request. Innovcable reserves the right to change this catalogue without prior notice.
    - The dimensional values are fictitious calculations, and Engineering should be consulted to obtain the real calculation.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español