Rubber Cables
1,8/3Kv single rubber cables
INNOVCABLE NSGAFÖU - 1.8/3 kV
- Conductor material: bare copper or tinned (SN) wires
- Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
- Insulation: CECO™ Special Elastomeric Compound.
- Outer jacket: CEAC™ Special Elastomeric Compound impact, oil, UV and flame resistant, halogen free.
- Outer cover in BLACK, RAL 9005 colour.
- Rated voltage: 1.8/3 kV
- Test voltage: 6 kV
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Min. bending radius: min. 5 x d;
Identification
INNOVCABLE - NSGAFÖU mm² 1,8/3 kV 125°C OF:XXXX/YEAR.
Applicable Specifications
Applications
Fixed installations of railway vehicles and buses, dry environments, in closed installation tubes and channels. Also used in flexible unit connections.
or fixed, that in railway vehicles and buses, as well as in dry environments, in flexible unit connections.
Cables with an operating voltage of 3 KV when applied in installations of voltages up to 1000 V are classified as short circuit and earth leakage connection, protected.
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125° C
Movable Min/max: -25° C / +125° C
Constructive Data
Notes
- Innovcable reserves the right to modify this catalogue without prior notice.
INNOVCABLE NSHXAFÖ - 1,8/3 kV
- Conductor material: Tinned copper wires (SN)
- Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
- Insulation: CECO™ Special Elastomeric Compound non-halogen and free of toxic fumes.
- Outer cover: CEAC™ Special Elastomeric Compound impact, oil, UV and flame resistant and non-halogen and toxic smoke free.
- Outer cover in BLACK, RAL 9005.
- Rated voltage: 1.8/3 kV
- Test voltage: 6 kV
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Min. bending radius: min. 5 x d;
Identification
INNOVCABLE - NSHXAFÖ mm² 1,8/3 kV 125°C OF:XXXX/YEAR.
Applicable Specifications
Applications
Fixed installations of railway vehicles and buses, dry environments, in closed installation tubes and channels. Also used in flexible unit connections.
or fixed, that in railway vehicles and buses, as well as in dry environments, in flexible unit connections.
Cables with an operating voltage of 3 KV when applied in installations of voltages up to 1000 V are classified as short circuit and earth leakage connection, protected.
-Halogen free
-UV resistant
-Ozone resistance
-Anti-Flame
-Low smoke density
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125° C
Movable Min/max: -25° C / +125° C
Constructive Data
Notes