Marine Cables - IEC Standard

Marine instrumentation cables 150/250V (300V)

    INNOVCABLE INNOVSHORE CONTROL / INSTRUMENTATION 150/250V (300V)

    1. Conductor composed of electrolytic bare copper wires or tinned, soft temper, class 5 stranding, in accordance with IEC 60228.*1,7
    2. Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3. LSOH halogen-free polyolefin compound (SHF1) final coating, grey colour. *2,5

    Identification

    - External Engraving:
    INNOVCABLE INNOVSHORE CONTROL/INSTRUMENTATION __mm² 0.15/0.25KV 90°C OF: XXXX/YEAR

    Conductors - insulation in white or black, numbered sequentially. *3

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Used on board ships in fixed installations, trays, troughs, conduits, panels, among others. Recommended for use in control, command and signalling circuits in accordance with IEC 60092-352. INNOVSHORE CONTROL/INSTRUMENTATION cables 0.15/0.25KV offer maximum resistance to chemical products, humidity and UV rays. Non-halogenous and with improvement under fire conditions, anti-flame, it does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 0,50mm² / 71 x 2,50mm²
    - 52 x 4,00mm² / 52 x 4,00mm² / 42 x 6,00mm².
    - 42 x 6,00mm²
    - 20 x 10,0mm²
    4) Insulation material of the veins:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE CONTROL / INSTRUMENTATION SHIELDED BTC/BTS 150/250V (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding, according to IEC 60228. *1,7
    2) Conductor insulation is made of special halogen-free compound LSOH (HF-90). *4
    3) Crimping or extruded filling.
    4) Shielding: Braided bare copper (BTC) or tinned copper (BTS) wires with coverage >90%. *8
    5) Final covering in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5

    Identification

    External recording:
    INNOVSHORE CONTROL/INSTRUMENTATION CABLE BLINDED BTC/BTS __ x __mm² 0.15/0.25KV 90°C OF: XXXX/YEAR

    Conductors - insulation in white or black, numbered sequentially. *3

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They have excellent protection against electromagnetic interference.
    They are used in fixed installations, trays, gutters, conduits, panels, among others. Indicated for use in control circuits, command and signalling, power supply, machine connection, among other environments. The INNOVSHORE CONTROL/INSTRUMENTATION BLINDED BTC/BTS 0,15/0,25KV CABLE offers maximum resistance to chemical products, humidity and UV rays. Non halogenous and improved under fire condition, anti-flame, does not produce toxic and corrosive gases. Exceeds IEC's specifications indicated.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections and number of veins.
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of shielding:
    BTS - Tinned copper wire braided shield
    BTC - Braided shielding of bare copper wires

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION SHIELDED BF 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Covering in halogen-free polyolefinic compound LSOH (SHF1), in gray colour. *2,5

    Identification

    - External Engraving:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BF __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YEAR.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION BLINDED BF Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Non-halogen and anti-flame cable, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External Coating Colors: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION SHIELDED BFI 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Halogen-free polyolefin LSOH (SHF1) cover, in gray colour. *2,5

    Identification

    - External Engraving:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BFI __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YEAR.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION Cables BLINDED BFI 0.15/0.25KV (300V) are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION SHIELDED BFIC 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5-) Collective shielding in aluminum-polyester tape, with flexible drainage conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Covering in halogen-free polyolefin compound LSOH (SHF1), in grey colour. *2,5

    Identification

    - External Engraving:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BFIC __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YEAR.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION BLINDED BFIC 0,15/0,25KV (300V) Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED ATC/ATS 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    5) Polyester Tape.
    6) Frame: bare copper wire braid (ATC) or tinned copper wire (ATS) with coverage >90% *8
    7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    - External recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armed cable provides protection where required.
    They are used in fixed installations to conduct analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, various sensor and meter connections, powering conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMORED ATC/ATS 0.15/0.25KV (300V) Instrumentation cables have excellent flexibility, resistance to chemicals, humidity and UV rays. Armored cable made from a braid of bare copper wires (ATC) or tinned copper wires (ATS). Non-halogen and flame retardant, producing no toxic or corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED ATA/AFC/AFA 0.15/0.25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    5) Inner jacket made of halogen-free polyolefin LSOH compound (SHF1). *5
    6) Frame: Galvanized steel wire braid (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
    7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey colour. *2,5

    Identification

    - External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where required.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED ATA/AFC/AFA 0.15/0.25KV (300V) Instrumentation Cables have excellent flexibility, resistance to chemicals, humidity and UV rays. Reinforced cable with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    AFC - Copper tape frame
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATA/AFC/AFA BF 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Collective shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Internal cover in halogen-free polyolefinic compound (SHF1). *5
    6) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
    7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey colour. *2,5

    Identification

    - External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BF __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where required.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATA/AFC/AFA BF 0,15/0,25KV (300V) Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    AFC - Copper tape frame
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATA/AFC/AFA BFI 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Internal cover in halogen-free polyolefinic compound (SHF1). *5
    6) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
    7) Halogen-free polyolefin LSOH (SHF1) compound cover, grey in colour. *2,5

    Identification

    - External recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFI __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where required.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/BLINDED ATA/AFC/AFA BFI 0.15/0.25KV (300V) Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    AFC - Copper tape frame
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATA/AFC/AFA BFIC 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Collective shield in aluminum-polyester tape, with flexible drainage conductor, formed by electrolitic tinned copper wires, soft temper.
    6) Internal cover in halogen-free polyolefinic compound (SHF1). *5
    7) Frame: braided galvanised steel wire (ATA) with coverage >90%; copper tape (AFC) or galvanised steel tape (AFA) applied with overlap. *8
    8) Cover in LSOH halogen-free polyolefin compound (SHF1), in grey colour. *2,5

    Identification

    - External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFIC __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where required.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/WELDED ATA/AFC/AFA BFIC 0,15/0,25KV (300V) Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATA - Galvanized steel wire braid frame
    AFC - Copper tape frame
    AFA - Galvanized steel tape frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATC/ATS BF 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Polyester tape / extruded filling.
    6) Frame: bare copper wire braid (ATC) or tinned copper wire (ATS) with coverage >90% *8
    7) LSOH halogen-free polyolefin compound (SHF1) cover, grey colour. *2,5

    Identification

    - External recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BF __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    Armoured cable provides protection where required.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATC/ATS BF 0,15/0,25KV (300V) Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATC - Bare copper wire braided frame
    ATS - Tinned copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATC/ATS BFI 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shield in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    5) Polyester tape.
    6) Frame: braided bare copper (ATC) or tinned copper (ATS) wires, coverage >90%.* 8
    7) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    - External recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFI __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/BLINDED ATC/ATS BFI 0.15/0.25KV (300V) Instrumentation Cables are recommended in cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATS - Tinned copper wire braided frame
    ATC - Bare copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMOURED/SHIELDED ATC/ATS BFIC 0,15/0,25KV (300V)

    1) Conductor formed by electrolytic bare copper wires or tinned, soft temper, class 5 stranding. IEC 60228. *1,7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with section 0,5mm², in LSOH (HF-90) compound, Identification through insulation in blue colour (only for cables with 2 or more pairs, suits or blocks) - (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by electrolitic tinned copper wires, soft temper.
    6) Polyester tape.
    7) Armature: braided bare copper (ATC) or tinned copper (ATS) wires, coverage >90%.* 8
    8) Cover in polyolefin compound halogen-free LSOH (SHF1), in grey colour. *2,5

    Identification

    - External recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFIC __mm² 0.15/0.25KV (300V) 90°C OF: XXXX/YE.

    Of the conductors - through the colours of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in pairs).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Strings: IEC 60228
    Primary Isolation: 150/250 V (300 V) - IEC 60092-376.
    Selection and installation of electrical cables: IEC 60092-352.
    Meets the requirements for firing test - IEC 60332-1 and IEC 60332-3-22 , category "A".
    Certifications can be Batch Approval or Type Approval (depending on certification and certifier) - Please contact us for further details.
    Shipborne energy cables - General construction and testing requirements: IEC 60092-350
    Insulation materials and outer jacket for use on board offshore units, power, control, instrumentation and telecommunication cables: IEC 60092-360
    Common test methods for insulation and outer jacket of materials of electric cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding environment of offshore drilling and the marine industry.
    They are used in fixed installations, for conducting analog (4 - 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, power supply to conventional and electronic relays, in industrial environments in general. INNOVSHORE INSTRUMENTATION ARMED/PLUGGED ATC/ATS BFIC 0,15/0,25KV (300V) Instrumentation Cables are recommended in those cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the occurrence of "crosstalk" (crosstalk) between the various pairs/pairs, providing electrical discharge of the same. Excellent flexibility, resistance to chemical products, humidity and UV rays. Cable armed with galvanized steel wires. Non-halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS DUTY: 90°C - IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) Tinned copper conductor can be manufactured in class 2.
    2) External layer colours: Nomenclature to be added at the end of the code: VM - Red // VD - Green // BR - White // PT - Black // AZ - Blue // CZ - Gray.
    We can manufacture other colours on request.
    3) Different sections and amount of veins, maximum up to:
    - 71 x 2 x 0,50mm² / 71 x 2 x 2,50mm²
    - 71 x 3 x 0,50mm² / 71 x 3 x 2,50mm².
    - 36 x 4 x 0,50mm² / 36 x 4 x 2,50mm².
    4) Vein insulation material:
    EPR - 90 ºC
    HEPR - 90 ºC
    XLPE - 90 ºC
    5) Material of the intermediate layer and the cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillers of compatible material may be used.
    7) Nomenclature to be added at the end of the code according to the conductor type:
    Bare copper conductor - CN
    Tinned copper conductor - SN
    8) Types of armatures:
    ATS - Tinned copper wire braided frame
    ATC - Bare copper braid frame

    **Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE NAVAL COAXIAL RG6 ARMED

    Conductors: Ø=0.72±0.025mm
    Dielectric: PE Ø=4.70±0.10mm
    Shielding 1: Al / polyester / Al. 100% covered
    Shielding 2: Tinned copper braid 144 x 0.16mm
    Intermediate cover: SHF1 LSZH, low smoke and toxic gas emission
    Armour: mesh of galvanized steel wire 144 x0,16mm
    External cover: SHF1 LSZH, low smoke and toxic gas emission, black
    ELECTRICAL CHARACTERISTICS:
    Impedance: Ω75+/-5
    Nominal Attenuation@100MHz dB/100m 6.9
    Nominal attenuation@200MHz dB/100m 9.0
    Nominal attenuation@300MHz dB/100m 11.8
    Rated attenuation@400MHz dB/100m 13.1
    Rated attenuation@500MHz dB/100m 15.4
    Rated attenuation@900MHz dB/100m 21.5
    Rated attenuation @1700MHz dB/100m 29.4
    Capacitance pF/m 53.5
    Propagation speed % 83
    DCR conductor Ω/km 21.4
    DCR shielding Ω/km 7.5
    Inductance μH/m 0.32
    Delay time ns/m 4
    THERMAL AND MECHANICAL CHARACTERISTICS:
    Bending radius : 15×OD.
    End diameter: 11,2mm

    Identification

    INNOVCABLE COAXIAL RG6 ARMOURED - IEC 60332-3-22

    Applicable Specifications

    IEC 60092-350
    IEC 60754-1,2
    IEC 61034-1,2
    IEC 60332-3-22
    NEK 606:2004

    Applications

    75Ω coaxial cable suitable for installation on board ships and other indoor marine environments.

    Maximum Conductor Temperature

    -30℃ ~ +75℃.

    Notes

    **Innovcable reserves the right to change this catalogue without prior notice.