Naval Cables – IEC Standard

Naval instrumentation cables 0.6/1kV

    INNOVCABLE INNOVSHORE SHIELDED INSTRUMENTATION BF 0.6/1kV

    Naval cables Innovshore Instrumentation Armored Instrumentation BF 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore instrumentation BF instrumentation are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of “diaphony) among the various pairs/tender, providing electric discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Non-halogen and anti-flame cable, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE SHIELDED INSTRUMENTATION BFI 0.6/1kV

    Naval cables Innovshore Instrumentation Instrumentation Armored BFI 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BFI __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation BFI Instrumentation are recommended for cases where excellent levels of protection against external electromagnetic interference is required, and maximum immunity against the emergence of “diaphony) among the various pairs/tender, providing their electrical discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. Naval cables are not halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE SHIELDED INSTRUMENTATION BFIC 0.6/1kV

    Naval cable instrumentation Innovshore instrumentation Bfic 0.15 and 0.25kv

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5-) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation Instrumentation Bfic 0.6/1KV are recommended for excellent levels of protection against external electromagnetic interference, and maximum immunity against the emergence of “CrossStalk” (diaphony) among the various pairs/tender, providing their electric discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED INSTRUMENTATION ATC/ATS 0.6/1kV

    Naval Cable Innovshore Instrumentation ARMED INSTRUMENTATION ATCATS 0.15 and 0.25KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    5) Polyester tape.
    6) Frame: Braid of bare copper wires (ATC) or tinned copper wires (ATS) with coverage >90% *8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore instrumentation armed instrumentation ATC/ATS 0.6/1kV have excellent flexibility, resistance to chemicals, mobs and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATC – Bare copper wire braid frame
    ATS – Braid frame of tinned copper wire

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED INSTRUMENTATION ATA/AFC/AFA 0.6/1kV

    Naval Cable Innovshore Instrumentation Armed Instrumentation ATA AFC AFA 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    5) Inner cover in halogen-free polyolefin compound LSOH (SHF1). *5
    6) Frame: Braid of galvanized steel wires (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation Armed Instrumentation ATA/AFC/AFA 0.6/1KV have excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/SHIELDED ATA/AFC/AFA BF 0.6/1kV

    Cable Naval Instrumentation Innovshore Instrumentation Stress Oblinted ATA AFC AFA BF 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Inner cover made of halogen-free polyolefin compound (SHF1). *5
    6) Frame: Galvanized steel wire braid (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore instrumentation armed/armored instrumentation ATA/AFC/AFA BF 0.6/1kV are recommended for excellent levels of external electromagnetic interference protection, and maximum immunity against the appearance of “diaphon” among the various pairs/tender, providing electric discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED/SHIELDED INSTRUMENTATION ATA/AFC/AFA BFI 0.6/1kV

    Cable Naval Instrumentation Innovshore armed instrumentation shot AFC AFA BFI 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Inner cover made of halogen-free polyolefin compound (SHF1). *5
    6) Frame: Galvanized steel wire braid (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFI __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore instrumentation armed/armored instrumentation/ATA/AFC/AFA BFI 0.6/1KV are recommended for excellent levels of protection against external electromagnetic interference, and maximum immunity against the emergence of “diaphon” among the various pairs/tender, providing electric discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/SHIELDED ATA/AFC/AFA BFIC 0.6/1kV

    Cable Naval Instrumentation Innovshore armed instrumentation ATA AFC AFA Bfic 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    6) Inner cover made of halogen-free polyolefin compound (SHF1). *5
    7) Frame: Galvanized steel wire braid (ATA) with coverage >90%; copper tape (AFC) or galvanized steel tape (AFA) applied with overlap. *8
    8) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATA/AFC/AFA BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore instrumentation armed/armored instrumentation/ATA/AFC/AFA BFI 0.6/1kV are recommended for excellent levels of external electromagnetic interference protection, and maximum immunity against the appearance of “diaphon” among the various pairs/tender, providing electric discharge. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/ARMORED ATC/ATS BF 0.6/1kV

    Cable Naval Instrumentation Innovshore armed instrumentation ATC ATS BF 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Polyester tape / extruded filling.
    6) Frame: Braid of bare copper wires (ATC) or tinned copper wires (ATS) with coverage >90% *8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BF __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable prove protection where it is required.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation Armed/Armored Instrumentation ATC/ATS BF 0.6/1kV are recommended for excellent levels of protection against external electromagnetic interference, and maximum immunity against the appearance of “Crossstalk” (diaphony) among the various pairs/tender, providing electric discharge of them. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATC – Bare copper wire braid frame
    ATS – Braid frame of tinned copper wire

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/ARMORED ATC/ATS BFI 0.6/1kV

    Cable Naval Instrumentation Innovshore armed instrumentation ATC ATC BFI 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Polyester tape.
    6) Frame: Braid of bare copper (ATC) or tinned copper (ATS) wires with coverage >90%.* 8
    7) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFI __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation Armed/Armored Instrumentation ATC/ATS BFI 0.6/1kV are recommended for excellent levels of protection against external electromagnetic interference, and maximum immunity against the emergence of “diaphon” among the various pairs/tender, providing electric discharge of them. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATS – Tinned copper wire braid frame
    ATC – Braid frame of bare copper wires

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE INSTRUMENTATION ARMED/ARMORED ATC/ATS BFIC 0.6/1kV

    Naval Cable Innovshore Instrumentation Armed instrumentation ATC ATS BFI 0.15 and 0.25kV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding. IEC 60228. *1.7
    2) Insulation in special halogen-free compound LSOH (HF-90). *4
    3) Communication conductor with 0.5mm² section, in LSOH compound (HF-90), Identification through blue insulation (only for cables with 2 or more pairs, triples or quads) – (Optional). *4
    4) Individual shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    5) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    6) Polyester tape.
    7) Frame: Braid of bare copper (ATC) or tinned copper (ATS) wires with coverage >90%.* 8
    8) Cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE INSTRUMENTATION ATC/ATS BFIC __mm² 0.6/1kV 90°C OF: XXXX/YEAR.

    Of the conductors – through the colors of the insulation, being:
    black and white (cables in pairs)
    black, white and red (cables in bundles).
    black, white, red and green (cables in blocks).*3

    Identification through sequential numbering.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV – IEC 60092-353
    Choice and installation of electrical cables: IEC 60092-352.
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Mobile and fixed offshore units – Electrical installations – Part 4: Cables – IEC 61892-4
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed installations, conducting analog (4 - 20MA) and digital signals, point -to -point instrumentation, Hart ® protocol, various sensor connections and meters, conventional and electronic relay feed, in general industrial environments. Naval cables Innovshore Instrumentation Armed/Armored Instrumentation ATC/ATS BFI 0.6/1kV are recommended for excellent levels of protection against external electromagnetic interference, and maximum immunity against the appearance of “Crossstalk” (diaphony) among the various pairs/tender, providing electric discharge of them. Excellent flexibility, resistance to chemicals, humidity and UV rays. Armed cable with galvanized steel wires. No halogen and anti-flame, not producing toxic and corrosive gases.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.
    3) Different sections and number of veins, maximum up to:
    • 71 x 2 x 0.50mm² / 71 x 2 x 2.50mm²
    • 71 x 3 x 0.50mm² / 71 x 3 x 2.50mm²
    • 36 x 4 x 0 .50mm² / 36 x 4 x 2.50mm²
    4) Material of vein insulation:

    EPR


    90
    ºC
    HEPR

    90 ºC 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATS – Tinned copper wire braid frame
    ATC – Braid frame of bare copper wires

    Naval cables instrumentation

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.