Control Cables – NBR 7289 / 7290 / 16442

Control cables – NBR 7289

    INNOVCABLE SB CONTROL CABLE

    Control cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding.
    2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A) 70ºC.
    3) Polyester tape separator.
    4) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7289 – Control cables with extruded PE or PVC insulation for voltages up to 1 kV – Performance requirements
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    Notes

    The SB CONTROL CABLE may be manufactured in another section, size or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    OTHER CONSTRUCTION OPTIONS:
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BF CONTROL CABLE

    Ribbon Armored Control Cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shielding in aluminized polyester tape with tinned copper drain wire.
    4) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has collective protection in aluminized polyester tape against electromagnetic interference. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF CONTROL CABLE may be manufactured in another section, dimensional or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Cover material:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex).

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BF FC CONTROL CABLE

    Armored control cable on tape and copper tape

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shielding in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Copper tape shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper tape against electromagnetic interference. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF FC CONTROL CABLE may be manufactured in another section, size or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BF FA CONTROL CABLE

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shielding in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel strip shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection using galvanized steel tape. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF FA CONTROL CABLE can be manufactured in another section, dimensional or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BF BTC CONTROL CABLE

    Aluminated polyester ribbon controlled control cable and copper braid

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shielding in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Copper braid shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has collective protection in aluminized polyester tape and copper braid against electromagnetic interference. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF BTC CONTROL CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BF BTA CONTROL CABLE

    Aluminated polyester ribbon controlled control cable and steel braid

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Separator in polyester tape and collective shielding in aluminized polyester tape with tinned copper drain wire.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel braid shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has collective protection against electromagnetic interference and mechanical protection of galvanized steel braid. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BF BTA CONTROL CABLE can be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E
    -105ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BTC CONTROL CABLE

    Armored Copper braid control cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Bare copper braid shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    •Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    •Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has protection against EMV electromagnetic interference. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    PVC/A -70ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NBR NM IEC 60332-3-23 (Category B)

    Notes

    The BTC CONTROL CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    OTHER CONSTRUCTION OPTIONS:
    We can manufacture upon request in other configurations.
    1-Tinned copper conductor.
    Class 2 stringing.
    2-Different sections, colors and number of veins, maximum up to:
    •71 x 0.50mm² / 71 x 2.50mm²
    •52 x 4.00mm²
    •42 x 6.00mm²
    •20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4-Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BTA CONTROL CABLE

    Armored Copper braid control cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel braid shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has mechanical protection made of galvanized steel braid. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT CIRCUIT REGIME: 160ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NM IEC 60332-3-23 (Category B)

    Notes

    The BTA CONTROL CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BFA CONTROL CABLE

    Steel Ribbon Armored Control Cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Galvanized steel strip shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has mechanical protection made of galvanized steel tape. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT CIRCUIT REGIME: 160ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NM IEC 60332-3-23 (Category B)

    Notes

    The BFA CONTROL CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE BFC CONTROL CABLE

    Steel Ribbon Armored Control Cable

    1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 5 NBR NM 280 stranding
    . 2) Insulation in thermoplastic compound based on polyvinyl chloride (PVC/A).
    3) Polyester tape separator.
    4) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC /ST1).
    5) Copper tape shielding.
    6) Non-hygroscopic tape.
    7) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).

    • Insulation voltage:
    Up to 1.0mm² – 500V
    From 1.50mm² to 10.00mm² – 1000V
    • Routine tests:
    Electrical resistance of the conductor at 20ºC
    Electrical voltage in Alternating Current
    Insulation resistance.

    Identification

    White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). It can also be constructed with colored veins.

    Applicable Specifications

    ABNT/MERCOSUL: NM-280 and NM-IEC
    NBR NM IEC 60332-3-23 (Category B)
    ABNT: NBR 7290 (when manufactured with insulation/final cover in XLPE or HEPR/PVC - codes change)
    ABNT: NBR 13248 (when manufactured with HEPR/LSZH insulation/final cover - the codes change).
    ABNT: NBR 7289 (when manufactured with PVC/PVC insulation/final cover – codes indicated in the table below)
    ABNT: NBR 6251

    Applications

    They are used in fixed installations in control, command and signaling circuits of electrical equipment, structured cabling, machine connections, button panels, power supply, microprocessed systems, in automation of substations, generating plants, industrial and chemical areas, among others.
    They are applied in fixed conduit systems (embedded or exposed), channels, duct banks, cable trays, beds, electrical panels, among other applications. It has copper tape protection against electromagnetic interference. This cable has good flexibility, resistance to UV, weather and humidity and certain chemicals.

    Maximum Conductor Temperature

    IN CONTINUOUS REGIME: 70ºC
    IN SHORT CIRCUIT REGIME: 160ºC
    – Flame retardant

    FLAME RESISTANT / SELF-EXTINGUISHING – MEETS THE FLAME RESISTANCE REQUIREMENT ACCORDING TO NM IEC 60332-3-23 (Category B)

    Notes

    The BFC CONTROL CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.

    CONSTRUCTION OPTIONS:
    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Class 2 stringing.
    2- Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    3- Insulation material veins / other temperatures:

    /
    E -105ºC ºC HEPR – 90 ºC
    PE – 80 ºC
    4- Material of the intermediate layer and cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, greases and other chemical products.
    LSZH (non-halogenated polyolefin compound)
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.