Flexible Special Control Cables

Harmonized Control Cables

    INNOVCABLE H05VV5-F

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: Special PVC 70°C – White or black veins identified by sequential numerical engraving in black or yellow with earth green (G).
    -Twisted in layers.
    – External cover in special PVC resistant to oils, greases, acids, manufactured in Gray RAL 7001.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 300/500V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – Flame resistant and flame retardant in accordance with IEC 60332-1

    Identification

    – All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
    External identification engraving:
    INNOVCABLE H05VV5-F n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, fixed and flexible applications without traction, can be applied in dry and humid locations. Can be applied outdoors with UV application. Flame retardant and flame retardant in accordance with IEC 60332-1. Resistant to oils, greases, acids. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +70°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE H05VVC4V5-K

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: Special PVC 70°C – White or black veins identified by sequential numerical engraving in black or yellow with earth green (G).
    -Twisted in layers.
    – Protective intermediate cover in special PVC.
    – Shielding: tinned copper wire shielding, 85% coverage.
    – External cover in special PVC resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    – Manufactured in Gray RAL 7001.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 300/500V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – Min radius. of curvature fixed use:6 xd
    – Min radius. of curvature if movable: 12 xd
    – Flame retardant and flame retardant in accordance with IEC 60332-1

    Identification

    – All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
    External identification engraving:
    INNOVCABLE H05VVC4V5-K n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and humid locations. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1. Resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. Additional mechanical protection through the intermediate frame.

    Maximum Conductor Temperature

    -40°C / +70°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FG7OH1R

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: HEPR Rubber – G7 Quality – White or black veins identified by sequential numerical engraving in black or yellow with or without earth green (G).
    – Twisted in layers.
    – Protective intermediate cover in special PVC or textile filament (Application depends on the variables gauge and number of veins)
    – Shielding: Copper tape
    – External cover in special PVC
    – Made in black.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 600/1000V
    – Test voltage: 4,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 10 MΩ X Km.
    – Min radius. of curvature fixed use: 8 xd
    – Short circuit temperature: +250 ° C
    – Flame retardant and flame retardant in accordance with CEI 20-22 II – IEC 60332-34, CEI EN 60332-1

    Identification

    – All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
    External identification recording:
    INNOVCABLE FG7OH1R n (x) or (G) mm² 600/1000V OF: XXXX/YEAR

    Applicable Specifications

    CEI 20-22II
    UNEL 35377
    CEI 20-37 pt.2 (EN50267)
    CIS 20-13
    CEI 20-35 (EN60332-1)
    CIS 20-52

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed applications in internal and external environments, can be applied in dry and humid locations. Has UV protection (external use). Protective shielding against EMC electromagnetic interference. Underground placement is acceptable even if not protected.

    Maximum Conductor Temperature

    -25°C / +90°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.
    – The dimensional values ​​are fictitious calculations, and engineering must be consulted to obtain the real calculation.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE FG7OH2R

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: HEPR Rubber – G7 Quality – White or black veins identified by sequential numerical engraving in black or yellow with or without earth green (G).
    – Twisted in layers.
    – Protective intermediate cover in special PVC or textile filament (Application depends on the variables gauge and number of veins)
    – Shielding: Bare copper mesh
    – External cover in special PVC
    – Made in black.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 600/1000V
    – Test voltage: 4,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 10 MΩ X Km.
    – Min radius. curvature fixed use: 8 xd
    – Short circuit temperature: +250 ° C
    – Flame retardant and flame retardant in accordance with CEI 20-22 II – IEC 60332-34, CEI EN 60332-1

    Identification

    – All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
    External identification recording:
    INNOVCABLE FG7OH2R n (x) or (G) mm² 600/1000V OF: XXXX/YEAR

    Applicable Specifications

    CEI 20-22II
    UNEL 35377
    CEI 20-37 pt.2 (EN50267)
    CIS 20-13
    CEI 20-35 (EN60332-1)
    CIS 20-52

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed applications in internal and external environments, can be applied in dry and humid locations. Has UV protection (external use). Protective shielding against EMC electromagnetic interference. Underground placement is acceptable even if not protected.

    Maximum Conductor Temperature

    -25°C / +90°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.
    – The dimensional values ​​are fictitious calculations, and engineering must be consulted to obtain the real calculation.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.