FREQUENCY INVERTER CABLES
Servomotor cables
INNOVCABLE INNOVFREQUENCY – NBR 7286
PHASE CONDUCTOR:
1-) Phase conductor material: bare copper wires, soft temper. Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
INSULATION:
2-) Insulated with special double-layer compound (high modulus EPR/B) in the colors Black, Blue and White. Twisted in layers.
FILLING:
3-) Protective intermediate layer in special PVC.
CONCENTRIC CONDUCTOR:
4-) Copper wires applied helically. 50% section of the phase conductor for sections larger than 16.0mm² and equal section of the phase conductor for sections smaller than 16.0mm².
SHIELDING:
5-) Copper tape with a minimum thickness of 0.07mm with overlap.
COVERAGE:
6-) External cover in special flame-retardant PVC, resistant to weather and UV rays. In black color.
– Manufactured free of harmful substances and silicone.
– Nominal voltage: 0.6/1kv.
– Test voltage: 3,000 V.
– Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
– Min radius. of fixed use curvature:6 x d.
– Flame retardant and flame retardant in accordance with IEC 60332-1.
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
Identification
External recording in accordance with NBR 7286.
Conductor colors: Black, Blue and White.
Outer cover color: Black.
Applicable Specifications
Applications
Recommended for applications in Frequency Inverters, they have the fourth concentric conductor applied helically on the intermediate cover. In order to reduce electrostatic interference, copper tape is applied, ensuring better inverter performance, flexible and easy-to-install cable with insulation that increases current carrying capacity.
Maximum Conductor Temperature
Thermal limits according to ABNT NBR 6251:
– Permanent regime: 90ºC
– Overload regime: 130ºC
– Short circuit regime: 250ºC
Notes
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations, in addition to those specified below:
1- Tinned copper conductor.
Class 2 stringing.
2-
and
number of veins, maximum up to:
3- Insulation
material for veins /
other temperatures
: resistant to oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound)
OTHER COMPOUNDS
– Constructions below 10.0mm² do not affect the copper tape, the concentric neutral remaining in the same gauge as the conductor.
– We can produce several other cable options and configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE SERVOFLEX C PVC 1KV 4 SUPPLY COLORS + 2 SHIELDED PAIR
– Conductor material: bare copper wires
– Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Insulation: PVC / Control conductors: special PE
- Power veins: black or white numbered 1, 2, 3 and green (G) // Control veins: 0.34mm² pairs – black or white engraved BR1, BR2 // Control veins: pairs of up to 0.75mm², black or white, numbered 5, 6 and 7, 8.
– Shielding of power conductors copper mesh control with attenuation ≥ 55 dB.
-General shielding in tinned copper mesh, coverage of approximately 85%.
– External cover: special PVC resistant to oils, greases, acids, refrigerants and lubricants
– External cover in GRAY RAL7001.
– Nominal voltage: 0.6/1KV power conductors; Control conductors: 350/350V
– Test voltage: cable/cable 4000V – Cable/Mesh:2000V.
– Conductor resistance: at +20 °C according to DIN VDE 0295 class 5 and IEC 60228 class 5
-Resistance. insulation: at +20 °C ≥ 20 MGΩX Km.
– Current carrying capacity: according to DIN VDE0100.
– Min radius. curvature:7.5 xd
Identification
– External identification recording: INNOVCABLE SERVOFLEX C PVC n G mm² + 2 X (2 x mm²) 1Kv OF: XXXX/YEAR.
Applicable Specifications
Applications
Cable for servo motors with 4 power conductors + 2 shielded pairs, use in highly automated industrial processes, which require high quality and protective shielding from EMI electromagnetic interference. Manufactured based on specifications from leading manufacturers of servo drives/frequency inverters and control systems, as well as in compliance with VDE standards. Shielded power cable with control conductors for use in temperature or brake sensors for applications and drive systems, where normal mechanical and electrical applications are required, for fixed and flexible use, not recommended for mobile applications. Flame resistant and flame retardant in accordance with IEC 60332-2-1.Resistant to oils, greases, acids, refrigerants and lubricants.Suitable for dry and humid environments.
Maximum Conductor Temperature
-30°C / +80 °C
– Flame retardant and flame retardant in accordance with IEC 60332-2-1
Notes
– We can produce several other cable options and configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE SERVOFLEX SK C PUR 1KV 4 SUPPLY COLORS + 2 SHIELDED PAIR
– Conductor material: bare copper wires
– Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Insulation: INNOVLON
– Power veins: black or white numbered 1, 2, 3 and green (G)
– Control veins: black or white numbered 5, 6 and 7, 8.
– Shielding of control conductors in copper mesh, with drain wire, attenuation ≥ 55 dB.
-General shielding in tinned copper mesh, drain wire, coverage of approximately 85%.
– External cover: special PUR resistant to oils, greases, acids, refrigerants and lubricants, non-halogen.
– External cover in Orange RAL2003.
– Nominal voltage: 0.6/1KV power conductors; Control conductors: 350/350V
– Test voltage: cable/cable:4000V – Cable/Mesh:1500V – mesh/mesh:500V
– Conductor resistance: at +20 °C according to DIN VDE 0295 class 6 and IEC 60228 class 6
-Resistance. insulation: at +20 °C ≥ 20 MGΩX Km.
– Current carrying capacity: according to DIN VDE0100.
– Min radius. curvature:7.5 xd
Identification
– External identification recording: INNOVCABLE SERVOFLEX SK C PUR 4+2 -n G mm² + 2 X (2 x mm²) 0.6/1KV OF: XXXX/YEAR.
Applicable Specifications
Applications
Cable for servo motors with 4 power conductors + 2 shielded pairs, use in highly automated industrial processes, which require high quality and protective shielding from EMI electromagnetic interference. Manufactured based on specifications from leading manufacturers of servo drives/frequency inverters and control systems, as well as in compliance with VDE standards. Shielded power cable with control conductors for use in temperature or brake sensors for robotic and industrial applications and drive systems, where high mechanical and electrical applications are required, for mobile use. Flame resistant and flame retardant in accordance with IEC 60332-2-1.Resistant to oils, greases, acids, refrigerants and lubricants.Suitable for dry and humid environments. High lifespan. Great cost/benefit ratio. Halogen free. Cable with reduced dimensions and low weight.
Maximum Conductor Temperature
-50°C / +120°C
Notes
– We can produce several other cable options and configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE SERVOFLEX SK C PVC 1KV
– Conductor material: bare copper wires
– Conductor class:according to DIN VDE 0295 class 6 and IEC 60228 cl. 6
– Vein Isolation: special PVC.
– Power veins: black or white numbered sequentially with 1 green lane (G).
– Intermediate cover: Special PVC for mobile applications.
-General shielding in tinned copper mesh, coverage of approximately 85%.
– External cover: Special PVC for mobile use, resistant to oils, greases, acids, refrigerants and lubricants
– External cover in GRAY RAL7001.
– Nominal voltage: 0.6/1KV.
– Voltage test:4000V.
– Conductor resistance: at +20 °C according to DIN VDE 0295 class 6 and IEC 60228 class 6
-Resistance. insulation: at +20 °C ≥ 20 MGΩX Km.
– Current carrying capacity: according to DIN VDE0100.
– Min radius. curvature:7.5 xd
Identification
– External identification recording: INNOVCABLE SERVOFLEX SK C PVC
n G mm² 0.6/1KV OF: XXXX/YEAR.
Applicable Specifications
Applications
Cable for servo motors with normal requirements, use in highly automated industrial processes, which require high quality and protective shielding from EMI electromagnetic interference. Manufactured based on specifications from leading manufacturers of servo drives/frequency inverters and control systems, as well as in compliance with VDE standards. Power cable shielded against electromagnetic interference, compatible with between units and frequency converters in mobile applications, mobile drive systems and in the field of robotics and/or industrial installations. Flame retardant and flame retardant in accordance with IEC 60332-2-1.Resistant to oils, greases, acids, refrigerants and lubricants.Suitable for dry and humid environments. Cable with great cost/benefit ratio.
Maximum Conductor Temperature
-30°C / +80°C
– Flame retardant and flame retardant in accordance with IEC 60332-2-1
Notes
– We can produce several other cable options and configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV BLACK
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Insulation: XLPE 90° C
– Veins colored with earth green (G) in accordance with DIN VDE 0293-308.
– Twisted in layers.
– Helically applied polyester tape.
– Shielding: helically applied aluminized polyester tape and tinned copper wire shielding, 85% coverage.
– Special PVC outer cover resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)), in PT color.
– Manufactured free of harmful substances and silicone.
– Nominal voltage: 0.6/1KV
– Test voltage: 4,000 V
– Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
– Insulation resistance: Minimum 20 MΩX Km.
– Min radius. fixed use curvature: up to 12mmØ: 5 xd; up to 20mm Ø: 7.5 xd; > 20mm Ø: 10 x d.
– Min radius. of curvature if movable: up to 12mmØ: 10 xd; up to 20mm Ø: 15 xd; > 20mm Ø: 20 x d.
– Flame retardant and flame retardant in accordance with IEC 60332-1
Identification
– All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
External identification recording:
INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV BLACKn (x) or (G) mm² OF: XXXX/YEAR
Applicable Specifications
Applications
Cable for power, control and connections of electrical equipment, for use in servo motor systems with frequency inverter technology, for fixed and flexible applications without traction, can be applied in dry and humid locations. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1. Resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Operating voltage: 0.6/1kv. Manufactured free of harmful substances and silicone. Recommended for EMC applications.
Maximum Conductor Temperature
-40°C / +90°C
Notes
G = with 1 green conductor for earth;
x = no green conductor to earth (OZ).
– We can produce several other cable options and configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV-3 PLUS BLACK
– Conductor material: bare copper wires
– Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Insulation: XLPE
-Veins colored with earth green (G) in accordance with DIN VDE 0293-308.
-Twisted in layers.
– Polyester tape applied helically.
– Shielding: helically applied aluminized polyester tape and tinned copper wire shielding, 85% coverage.
– Black outer cover made of special PVC resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
– Free from harmful substances and silicone.
– Nominal voltage: 0.6/1KV
– Test voltage: 4,000 V
– Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
– Insulation resistance: Minimum 20 MΩX Km.
– Min radius. fixed use curvature: up to 12mmØ: 5 xd; up to 20mm Ø: 7.5 xd; > 20mm Ø: 10 x d.
– Min radius. curvature if movable: up to 12mmØ: 10 xd; up to 20mm Ø: 15 xd; > 20mm Ø: 20 x d.
– Flame retardant and flame retardant in accordance with IEC 60332-1
Identification
– All cables with identification (G) have 1 green conductor for earth, (x) without green conductor for earth.
External identification recording:
INNOVCABLE 2YSL(St)CYK-J 0.6/1 Kv EMV BLACKn (x) or (G) mm² OF: XXXX/YEAR
Applicable Specifications
Applications
Cable for power, control and connections of electrical equipment, for use in servo motor systems with frequency inverter technology, for fixed and flexible applications without traction, can be applied in dry and humid locations. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1. Resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Operating voltage: 0.6/1kv. Manufactured free of harmful substances and silicone. Recommended for EMC applications.
Maximum Conductor Temperature
-40°C / +90°C
Notes
G = with 1 green conductor for earth;
x = no green conductor to earth (OZ).
– We can produce several other cable options and configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.