Flexible Special Control Cables

Polyurethane Control Cables

    INNOVCABLE PUR (N)YMHC11YO GRAY – EMC

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: special PVC 70°C. – Up to 5 colored vein conductors in accordance with DIN VDE 0293-308; above 6 Innovcable color coded conductors with or without earth vein (G).
    -Twisted in layers.
    – Tinned copper mesh shielding, coverage of approximately 85%.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents and acids.
    – manufactured in Gray RAL 7001.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 300/500 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius:5 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green path to earth, External identification recording:
    INNOVCABLE PUR (N)YMHC11YO n (x) or (G) mm² 300/500V or 0.6/1kv OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    RAL 7001
    DIN VDE 0245, 0250 AND 0282

    Applications

    Cable for power, control and connections of electrical equipment in general, excellent product for electrical tools, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids. Excellent resistance to Abrasion and Impact, cut and tear proof. Microbe Resistant. Manufactured free of harmful substances and silicone. For EMC applications. Tinned copper mesh shielding against electromagnetic interference.

    Maximum Conductor Temperature

    Fixed: min-40°C / +70°C
    Mobile: min-5°C / +70°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce several other cable options and configurations upon request.
    – Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR (N)YMH11YO GRAY

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: special PVC 70°C. - White or black veins identified by sequential numerical engraving in black or yellow with or without earth green (G).
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents and acids.
    – manufactured in Gray RAL 7001.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 300/500 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius:5 xd
    – min. radius of curvature if movable:12.5xd.

    Identification

    – All cables with identification (G) have 1 green path for ground.
    – External identification engraving: INNOVCABLE PUR (N)YMH11YO n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    RAL 7001
    DIN VDE 0245, 0250 AND 0282

    Applications

    Cable for power, control and connections of electrical equipment in general, excellent product for electrical tools, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids. Excellent resistance to Abrasion and Impact, cut and tear proof. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +70°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce several other cable options and configurations upon request.
    – Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR (N)YMH11YO YELLOW

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Insulation: special PVC 70°C. – Up to 5 colored vein conductors in accordance with DIN VDE 0293-308; above 6 Innovcable color coded conductors with or without earth vein (G).
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents and acids.
    – manufactured in Yellow RAL 1016.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: 300/500 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius:5 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green route for earth, External identification recording:
    INNOVCABLE PUR (N)YMH11YO n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    RAL 1016
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0282

    Applications

    Cable for power, control and connections of electrical equipment in general, excellent product for electrical tools, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids. Excellent resistance to Abrasion and Impact, cut and tear proof. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +70°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR H05BQ-F

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Isolation: Special rubber 130°C.
    -Up to 5 colored vein conductors according to DIN VDE 0293-308, with green earth (G) after the third conductor.
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents and acids.
    – Made in Orange.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: H05BQ-F 300/500 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius: 4 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green route for earth, External identification recording:
    INNOVCABLE PUR H05BQ-F n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    DIN VDE 0282

    Applications

    Cable for electrical equipment, hand tools and other applications, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids. Excellent resistance to Abrasion and Impact, cut and tear proof. UV protection. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +130°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR H05BQ-F AQUA

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Isolation: Special rubber 130°C.
    -Up to 5 colored vein conductors according to DIN VDE 0293-308, with green earth (G) after the third conductor.
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents, acids, oils and water.
    – Made in Orange.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: H05BQ-F 300/500 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius: 4 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green route for earth, External identification recording:
    INNOVCABLE PUR H05BQ-F AQUA n (x) or (G) mm² 300/500V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    DIN VDE 0282

    Applications

    Cable for electrical equipment, hand tools and other applications, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids and oils. Excellent resistance to Abrasion and Impact, cut and tear proof. Can be used in constant use in water. UV protection. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +130°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR H07BQ-F

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Isolation: Special rubber 130°C.
    -Up to 5 colored vein conductors according to DIN VDE 0293-308, with green earth (G) after the third conductor.
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents and acids.
    – Made in Orange.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: H07BQ-F 450/750 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius: 4 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green route for earth, External identification recording:
    INNOVCABLE PUR H07BQ-F n (x) or (G) mm² 450/750 V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    DIN VDE 0282

    Applications

    Cable for electrical equipment, hand tools and other applications, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids. Excellent resistance to Abrasion and Impact, cut and tear proof. UV protection. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +130°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE PUR H07BQ-F AQUA

    – Conductor material: bare copper wires
    – Conductor class:according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    – Vein Isolation: Special rubber 130°C.
    -Up to 5 colored vein conductors according to DIN VDE 0293-308, with green earth (G) after the third conductor.
    -Twisted in layers.
    – External cover in special PUR with high resistance to abrasion, impacts, cuts, tears, lubricants, hydrolysis, solvents, acids, oils and water.
    – Made in Orange.
    – Manufactured free of harmful substances and silicone.
    – Nominal voltage: H07BQ-F 450/750 V
    – Test voltage: 3,000 V
    – Conductor resistance: according to DIN VDE 0295 class 5e IEC 60228 cl. 5
    – Insulation resistance: Minimum 20 MΩX Km.
    – min. Fixed use bending radius: 4 xd
    – min. radius of curvature if movable: 12.5xd

    Identification

    – All cables with identification (G) have 1 green path for earth, External identification recording:
    INNOVCABLE PUR H07BQ-F AQUA n (x) or (G) mm² 450/750 V OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293-308
    DIN VDE 0282

    Applications

    Cable for electrical equipment, hand tools and other applications, fixed and flexible applications without traction, can be applied in dry and humid locations. External use over a wide temperature range. Resistant to lubricants, hydrolysis, solvents, acids and oils. Excellent resistance to Abrasion and Impact, cut and tear proof. Can be used in constant use in water. UV protection. Microbe Resistant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    -40°C / +130°C

    Notes

    G = with 1 green conductor for earth;
    x = no green conductor for earth (OZ).
    – We can produce, upon request, several other options and cable configurations. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.