    INNOVCABLE INNOVSHORE POWER TINY 1 conductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1.4
    2) Insulation in special halogen-free polyolefinic compound LSOH – (SHF1). *2.5
    Conductor voltage: 0.6/1KV

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER TINY __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER TINY 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under anti-flame fire condition, not producing toxic and corrosive gases. All products exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) Identification and colors: Nomenclature to be added to the end of the code depending on the colors: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    4) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    5) Insulation material:
    SE
    SHF2

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER TINY 1 conductor 0.15/0.25KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1.4
    2) Insulation in special halogen-free polyolefinic compound LSOH – (SHF1). *2.5
    Conductor voltage: 0.15/0.25KV

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER TINY __mm² 0.15/0.25KV 90°C OF: XXXX/YEAR

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER TINY 0.15/0.25KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under anti-flame fire condition, not producing toxic and corrosive gases. All products exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) Identification and colors: Nomenclature to be added to the end of the code depending on the colors: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    4) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    5) Insulation material:
    SE
    SHF2

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER 1 Conductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.6
    2) Insulation in special halogen-free compound LSOH (HF-90).*3
    3 ) Cover in halogen-free polyolefin compound LSOH (SHF1).*2.4

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue
    We can manufacture other colors upon request.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 6) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER Multiconductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90).* 4
    3) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color.*2.5

    Identification

    External Recording:
    INNOVSHORE POWER CABLE Multiconductor __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Conductor insulation colors:
    2 conductors: black and white.
    3 conductors: black, white and red.
    4 conductors: black, white red and blue.
    5 conductors: black, white red, blue and gray.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among others in industrial environments in general. INNOVSHORE POWER Multiconductor 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    *We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections and number of veins.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER ARMED ATA/ATC/ATS/AFC/AFA – BTC/BTS 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.* 1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Shielding in braid of bare copper (BTC) or tinned copper (BTS) wires.*8
    4) Inner cover in halogen-free polyolefin compound LSOH (SHF1).*5
    5) Frame: Braid of steel wires galvanized (ATA), bare copper (ATC), tinned copper (ATS) with >90% coverage, copper tape (AFC) or steel tape (AFA), applied with overlap. *9
    6) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    External Recording:
    INNOVSHORE POWER ARMED CABLE ATA/ATC/ATS/AFC/AFA – BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Conductor insulation colors:
    2 conductors: black and white.
    3 conductors: black, white and red.
    4 conductors: black, white red and blue.
    5 conductors: black, white red, blue and gray.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    Armored cable provides protection where required. Braid shielding offers excellent protection against electromagnetic interference.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATA/ATC/ATS/AFC/AFA – BTC/BTS 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material:
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of shielding:
    BTC – Braided shielding of bare copper wires
    BTS – Braided shielding of tinned copper wires
    9) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    ATS – Braided frame made of tinned copper wires
    ATC – Braided frame
    braid of bare copper wires AFC – Frame in copper tape
    AFA – Frame in galvanized steel tape

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER ARMED ATA/ATC/ATS 1 Conductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.6
    2) Insulation in special halogen-free compound LSOH (HF-90)*3
    3) Frame: Braid of galvanized steel wires (ATA), bare copper (ATC) or tinned copper (ATS) with coverage >90%.*7
    4) Cover in halogen-free polyolefin compound LSOH (SHF1).*2.4

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER ARMED ATA/ATC/ATS __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    Armored cable provides protection where required.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATA/ATC/ATS 1 Conductor 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White / / PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 6) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    7) Types of frames:
    ATA – Galvanized steel wire braid frame
    ATS – Braid frame of ATC tinned copper wires
    – Braided frame of bare copper wires

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER ARMED ATC/ATS Multiconductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90).* 4
    3-) Banding or extruded filling.
    4) Frame: Braid of bare (ATC) or tinned (ATS) copper wires with coverage >90%.*8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color.*2.5

    Identification

    External Recording:
    INNOVSHORE POWER CABLE ARMED ATC/ATS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Conductor insulation colors:
    2 conductors: black and white.
    3 conductors: black, white and red.
    4 conductors: black, white red and blue.
    5 conductors: black, white red, blue and gray.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    Armored cable provides protection where required.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATC/ATS Multiconductor 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections and number of veins.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATS – Tinned copper wire braid frame
    ATC – Braid frame of bare copper wires

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER SHIELDED BTC/BTS 1 Conductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.6
    2) Insulation in special halogen-free compound LSOH (HF-90)*3
    3) Shielding: Braid of bare copper (BTC) or tinned copper (BTS) wires with coverage >90%.*7
    4) Composite coverage halogen-free polyolefin LSOH (SHF1).*2.4

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER SHIELDED BTC/BTS __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    The good quality of copper shielding reduces electromagnetic interference and electrical interference in electronic installations.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE SHIELDED POWER CABLE BTC/BTS 1 Conductor 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue // CZ – Grey.
    We can manufacture other colors upon request.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 6) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    7) Types of Shielding:
    BTS – Braided shielding of tinned copper wires
    BTC – Braided shielding of bare copper wires

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER SHIELDED BTC/BTS Multiconductor 0.6/1KV

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3-) Extruded binding or filling.
    4-) Shielding: Braid of bare copper (BTC) or tinned copper (BTS) wires with coverage >90%.*8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color.*2, 5

    Identification

    External Recording:
    INNOVCABLE INNOVSHORE POWER SHIELDED BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Conductor insulation colors:
    2 conductors: black and white.
    3 conductors: black, white and red.
    4 conductors: black, white red and blue.
    5 conductors: black, white red, blue and gray.

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    The good quality of copper shielding reduces electromagnetic interference and electrical interference in electronic installations.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER SHIELDED BTC/BTS Multiconductor 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections and number of veins.

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of shields:
    BTS – Braid of tinned copper wires
    BTC – Braid of copper wires naked

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE POWER ARMED ATA/AFC/AFA 0.6/1KV

    1) Conductor made up of bare or tinned electrolytic copper wires, soft temper, class 5 stringing. *1.7
    2) Special halogen-free compound LSOH (HF-90).*
    3) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
    4) Frame: Braid of galvanized steel wires (ATA) with >90% coverage, copper tape (AFC) or steel tape (AFA) applied with overlap. *8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color.*2.5

    Identification

    External Recording:
    INNOVSHORE POWER CABLE ATA/AFC/AFA __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Conductor insulation colors:
    2 conductors: black and white.
    3 conductors: black, white and red.
    4 conductors: black, white red and blue.
    5 conductors: black, white red, blue and gray.
    Multiconductors: > 5 conductors – white or black veins numbered sequentially.*3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry.
    Armored cable provides protection where required.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. INNOVSHORE POWER ARMED CABLE ATA/AFC/AFA 0.6/1KV cables offer maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3-) Other dimensions: from 1.5mm² to 70.0mm² (Also in AWG)
    Other formations up to 71 conductors (see maximum per gauge).

    )
    Vein insulation material:

    EPR
    – 90

    ºC
    HEPR – 90
    ºC compatible. 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE HIGH POWER ARMORED/ARMED 3.6/6KV (7.2KV)

    1. Conductor made up of bare or tinned electrolytic copper wires, soft temper, class 5 stranding.
    2. Semiconductor tape extruded onto the conductor.
    3. Insulation in thermoset compound based on halogen-free ethylenepropylene rubber (HF-EPR).
    4. Semiconductor tape extruded onto the insulation.
    5. Metallic shield formed by tinned copper wires.
    6. Inner cover in halogen-free polyolefin compound.
    7. Frame made of tinned copper wire braid (for single-core cables up to 95.0mm²) and galvanized steel tape (for single-core cables above 95.0mm² and multi-core cables).
    8. Cover in halogen-free polyolefin compound (SHF1), black.

    Identification

    External Recording:

    INNOVSHORE HIGH POWER CABLE BTS/ATS or AFA __ x __mm² 3.6/6KV 90°C OF: XXXX/YEAR.

    Conductor insulation colors:
    1 conductor: natural color insulation.
    3 conductors: colored (white, blue and red)

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – One and three core power cables with extruded solid insulation for nominal voltages 6 kV, 10 kV and 15 kV: IEC 60092-354
    Meets the requirements for burn test – IEC 60332-1-2 and IEC 60332-3-22.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Electrical installations on ships – Part 352: selection and installation of electrical cables: IEC 60092-352
    Halogen Free: IEC-60754-1/2
    Low smoke emission: IEC 61034- 1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the marine industry in medium voltage applications.
    Armored cable provides protection where required.
    They are used in fixed installations, in trays, gutters, conduits, panels, among others. Recommended for use in control, command and signaling circuits, power supply, machine connection, among other environments. The INNOVSHORE HIGH POWER BTS/ATS or AFA 3.6/6KV CABLE offers maximum resistance to chemicals, humidity and UV rays. Non-halogen and improved under fire conditions, flame retardant, does not produce toxic and corrosive gases. They exceed the indicated IEC specifications.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2 (upon request).
    2) External cover colors: Nomenclature to be added at the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.

    4

    )
    Vein

    insulation material : 7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDF Download PDF EnglishDownload PDF Español