Naval Cables – IEC Standard

Naval control cables

    INNOVCABLE INNOVSHORE CONTROL 0.6/1KV

    Naval cable control Innovshore-Controlle-061KV.

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.*1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    – External Recording:
    INNOVCABLE INNOVSHORE CONTROL __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    – White veins numbered sequentially, can be manufactured at customer request with a green vein (protective conductor). *3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    They are used in fixed facilities, trays, gutters, conduits, panels, among others. Naval cables control are indicated for use in control, command and signaling circuits, food, machine connection, among others in industrial environments in general. Innovshore cables 0.6/1kV offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    *We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, maximum up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Insulation material veins:
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE SHIELDED CONTROL BTC/BTS 0.6/1KV

    Naval cable control innovshore-batc bts

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Banding or extruded filling.
    4) Shielding: Braid of bare copper (BTC) or tinned copper (BTS) wires with >90% coverage. *8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    External Recording:
    INNOVSHORE SHIELDED CONTROL CABLE BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Of the conductors – white insulation numbered sequentially. *3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    It has excellent protection against electromagnetic interference.
    They are used in fixed facilities, trays, gutters, conduits, panels, among others. Naval cables control are indicated for use in control, command and signaling circuits, feeding, machine connection, among other environments. Innovshore cable cables Armored control BTC/BTS 0.6/1kV offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material :
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of shielding:
    BTS – Braided shielding of tinned copper wires
    BTC – Braided shielding of bare copper wires

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED CONTROL ATC/ATS 0.6/1KV

    Cable Naval Control Innovshore Armed Control ATC ATS

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Banding or extruded filling.
    4) Frame: Braid of bare copper (ATC) or tinned copper (ATS) wires with >90% coverage. *8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    External Recording:
    INNOVSHORE CABLE ARMED CONTROL ATC/ATS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR

    Of the conductors – white insulation numbered sequentially. *3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable provides protection where it is required.
    They are used in fixed facilities, trays, gutters, conduits, panels, among others. Naval cables control are indicated for use in control, command and signaling circuits, feeding, machine connection, among other environments. Innovshore cable cables ATC/ATS 0.6/1KV armed control offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material :
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATS – Tinned copper wire braid frame
    ATC – Braid frame of bare copper wires

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED CONTROL ATA/AFC/AFA 0.6/1KV

    Naval cable control Innovshore Armed Control Ata AFC AFA

    1) Conductor made up of bare or tinned electrolytic copper wires, soft temper, class 5 stringing. *1.7
    2) Special halogen-free compound LSOH (HF-90).*
    3) Inner jacket in halogen-free polyolefin compound LSOH (SHF1). *5
    4) Frame: Braid of galvanized steel wires (ATA) with >90% coverage, copper tape (AFC) or steel tape (AFA) applied with overlap. *8
    5) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color.*2.5

    Identification

    External Recording:
    INNOVSHORE CABLE CONTROL ATA/AFC/AFA __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Of the conductors – white insulation numbered sequentially.*3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable provides protection where it is required.
    They are used in fixed facilities, trays, gutters, conduits, panels, among others. Naval cables control are indicated for use in control, command and signaling circuits, feeding, machine connection, among other environments. Innovshore cable cables ATA/AFC/AFA 0.6/1KV cables offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material :
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    AFC – Ribbon frame copper
    AFA – Galvanized steel strip frame

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED/ARMORED CONTROL ATA/ATC/ATS/AFC/AFA – BF 0.6/1KV

    Naval cable control controlled control atc ats AFC AFA - BF

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.* 1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Collective shielding in aluminum-polyester tape, with flexible drain conductor, formed by tinned electrolytic copper wires, soft temper.
    4) Inner cover in halogen-free polyolefin compound LSOH (SHF1). *5
    5) Frame: Braid of galvanized steel wires (ATA), bare copper (ATC), tinned copper (ATS) with coverage >90%, copper tape (AFC) or steel tape (AFA), applied with overlap . *8.9
    6) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    External Recording:
    INNOVSHORE CABLE CONTROL ARMED ATA/ATC/ATS/AFC/AFA – BF __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Of the conductors – white insulation numbered sequentially.*3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable provides protection where it is required. The shield protects against electromagnetic interference.
    They are used in fixed installations, trays, gutters, conduits, panels, among others. Naval controls control are indicated for use in control, command and signaling circuits, feeding, machine connection, among other environments. Innovshore cable cables armed/armored control/ATC/AF/AFA - BF 0.6/1kV offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material :
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of frames:
    ATA – Galvanized steel wire braid frame
    ATS – Braid frame of tinned copper wires
    ATC – Frame in braid of bare copper wires
    AFC – Frame in copper tape
    AFA – Frame in galvanized steel tape
    9) Dimensions change in Frame function in copper tape or galvanized steel tape. Please consult.

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVSHORE ARMED/ARMORED CONTROL ATA/ATC/ATS/AFC/AFA – BTC/BTS 0.6/1KV

    Naval cable control controlled control atc ats AFC AFA - BTC BTS

    1) Conductor formed by bare or tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228.* 1.7
    2) Insulation of conductors in special halogen-free compound LSOH (HF-90). *4
    3) Shielding in braid of bare copper (BTC) or tinned copper (BTS) wires.*8
    4) Inner cover in halogen-free polyolefin compound LSOH (SHF1).*5
    5) Frame: Braid of steel wires galvanized (ATA), bare copper (ATC), tinned copper (ATS) with >90% coverage, copper tape (AFC) or steel tape (AFA), applied with overlap. *9
    6) Final cover in halogen-free polyolefin compound LSOH (SHF1), gray in color. *2.5

    Identification

    External Recording:
    CABLE INNOVSHORE CONTROL ATA/ATC/ATS/AFC/AFA – BTC/BTS __ x __mm² 0.6/1KV 90°C OF: XXXX/YEAR.

    Of the conductors – white insulation numbered sequentially.*3

    Applicable Specifications

    Stringing: IEC 60228
    Electrical installations on ships – Power cables for voltages of 1 kV and 3 kV: IEC 60092-353
    Meets the requirements for burning test – IEC 60332-1 and IEC 60332-3-22, category “A”.
    Low smoke emission: IEC 61034- 1/2
    Certifications can be Batch Approval or Type Approval (depending on the certification and the certifier) ​​– Consult us for more details.
    Shipboard Power Cables – General Construction and Testing Requirements: IEC 60092-350
    Insulation and outer jacket materials for use on board offshore units, power, control, instrumentation and telecommunications cables: IEC 60092-360
    Common test methods for insulation and outer jacket materials of electrical cables: IEC 60811
    Halogen Free: IEC-60754-1/2
    Application: IEC 60092 series.

    Applications

    Built and designed for the demanding offshore drilling environment and the naval industry.
    Armed cable provides protection where it is required. The braid shield offers excellent protection against electromagnetic interference.
    They are used in fixed facilities, trays, gutters, conduits, panels, among others. Naval cables control are indicated for use in control, command and signaling circuits, feeding, machine connection, among other environments. Innovshore cable cables armed/armored control/ATC/AF/AFA - BTC/BTS 0.6/1kV offers maximum resistance to chemicals, humidity and UV rays. No halogen and improvement under fire, anti-flame, does not produce toxic and corrosive gases. Exceed the specifications of the indicated IEC's.

    Maximum Conductor Temperature

    CONTINUOUS SERVICE: 90°C – IEC 60092-360
    SHORT CIRCUIT: 250°C

    Notes

    * We manufacture with other configurations:
    1) The tinned copper conductor can be manufactured in class 2.
    2) External cover colors: Nomenclature to be added to the end of the code: VM – Red // VD – Green // BR – White // PT – Black // AZ – Blue
    We can manufacture other colors upon request.
    3) Different sections, colors and number of veins, up to:
    • 71 x 0.50mm² / 71 x 2.50mm²
    • 52 x 4.00mm²
    • 42 x 6.00mm²
    • 20 x 10.0mm²
    4) Vein insulation material :
    EPR – 90 ºC
    HEPR – 90 ºC
    XLPE – 90 ºC
    5) Material of the intermediate layer and cover:
    ST2
    SE
    SHF2
    6) At Innovcable's discretion, separators and/or fillings made of compatible material may be used.
    7) Nomenclature to be added to the end of the code depending on the type of conductor:
    Bare copper conductor – CN
    Tinned copper conductor – SN
    8) Types of shielding:
    BTC – Braided shielding of bare copper wires
    BTS – Braided shielding of tinned copper wires
    9) Types of frames:
    ATA – Braided frame made of galvanized steel wires
    ATS – Braided frame made of tinned copper wires
    ATC – Braided frame
    braid of bare copper wires AFC – Frame in copper tape
    AFA – Frame in galvanized steel tape

    Naval Cables Control

    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.