Intrinsically safe cables

Intrinsic safety instrumentation cables

    INNOVCABLE RE-2X(St)2YSWAY-fl

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Layered twisted pairs.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – Intermediate cover in special PE, black.
    – Reinforced protection made of galvanized steel tape.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. of curvature: 10 xd

    Identification

    – External identification recording:
    INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)2YSWAY-fl nx 2 x mm² 300V 90°C OF: XXXX/YEAR.

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through the intermediate frame. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect due to special and differentiated shielding. Triple mechanical and electromagnetic interference protection.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE RE-2X(St)2YSWBY-fl

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Layered twisted pairs.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – Protective intermediate cover in special black PE.
    – Reinforced protection made of galvanized steel wire braid.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. curvature:10 xd

    Identification

    INNOVCABLE INSTRUMENTATIONCABLE INTRINSICALLY SAFE RE-2X(St)2YSWBY-fl nx 2 x mm² 300V 90°C OF: XXXX/YEAR.

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through the intermediate frame. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect due to special and differentiated shielding. Triple mechanical and electromagnetic interference protection.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE RE-2X(St)2YSWAY-fl PiMf

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Individual shielding of the pairs with aluminized polyester tape (PIMf) with 0.6mm tinned drain wire.
    – Layered twisted pairs.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – Intermediate cover in special PE, black.
    – Reinforced protection made of galvanized steel tape.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. of curvature: 10 xd

    Identification

    INNOVCABLE INSTRUMENTATIONCABLE INTRINSICALLY SAFE RE-2X(St)2YSWAY-fl PiMf nx 2 x mm² 300V 90°C OF: XXXX/YEAR.

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through the intermediate frame. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect due to special and differentiated shielding. Triple mechanical and electromagnetic interference protection.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE RE-2X(St)2YSWBY-fl PiMf

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Individual shielding of the pairs with aluminized polyester tape (PIMf) with 0.6mm tinned drain wire.
    – Layered twisted pairs.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – Protective intermediate cover in special black PE.
    – Reinforced protection made of galvanized steel wire braid.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. of curvature: 10 xd

    Identification

    INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)2YSWBY-fl PiMf nx 2 x mm² 300V 90°C OF: XXXX/YEAR.

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14. Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through the intermediate frame. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect due to special and differentiated shielding. Triple mechanical and electromagnetic interference protection.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE RE-2X(St)Yv-fl PiMf

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Layered twisted pairs.
    – Individual shielding of the pairs with aluminized polyester tape (PIMf) with 0.6mm tinned drain wire.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. curvature: 7.5 xd

    Identification

    INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)Yv-fl PiMf n _ x _ x mm² 300V 90°C OF: XXXX/YEAR.

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14 (Application regulations must be observed). Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect. Robust outer cover.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español

    INNOVCABLE RE-2X(St)Yv-fl

    – Conductor material: bare copper wires
    – Conductor class: according to DIN VDE 0295 class 4 and IEC 60228 cl. 4
    – Vein Insulation: XLPE (special cross-linked polyethylene) 90°C
    – White and black veins identified by sequential numerical recording.
    – Layered twisted pairs.
    – General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
    – External cover: special PVC resistant to oils, greases, acids.
    – External cover in BLUE or BLACK color for intrinsically safe systems and depending on the required application.
    – Nominal voltage: 300V
    – Test voltage: 1,500 V
    – Conductor resistance:
    0.5mm² – max.36.7 MΩXKm;
    0.75mm² – max.25.0 MΩXKm;
    1.5mm² – max.14.2 MΩXKm;
    – Resist. of insulation: Min.5 GΩX Km.
    – Capacitance: max 115 nF/Km
    – Inductivity: ca. 1mH/Km
    – Coupling: max 500nF/ 500m
    – Min radius. curvature: 7.5 xd

    Identification

    INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)Yv-fl n _x _ x mm² 300V 90°C OF: XXXX/YEAR

    Applicable Specifications

    NBR 10300
    EN 50288-7
    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    IEC 60079-14
    IEC 60332-1-2 and IEC 60332-3-24
    IEC 60079-14 zone 1+2 group II

    Applications

    Instrumentation cable for lossless transmission, measurement and process control technology of analog and digital signals. For use in intrinsically safe Zone 1 and Zone 2 Group II classified areas in accordance with IEC 60079-14 (Application regulations must be observed). Has UV protection (external use). Flame retardant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE – (cross-linked PE). Low attenuation and minimization of the crosstalk effect. Robust outer cover.

    Maximum Conductor Temperature

    -40° C / +90° C
    – Flame resistant and flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24

    – Can be made with other insulation:
    Vein insulation material / other temperatures:
    PVC/E -105ºC
    XLPE – 125 ºC
    HEPR – 90 ºC
    PE – 80 ºC

    Notes

    We can manufacture upon request in other configurations.
    1- Tinned copper conductor.
    Stringing class 5.
    2- Different sections and number of veins.

    3-
    Vein insulation material /

    other

    temperatures :
    PVC
    /
    E
    -105 ºC oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound).
    5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)

    – We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.

    Download Portuguese PDF Download PDF EnglishDownload PDF Español
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.