Instrumentation Cables – NBR 10300
Individually shielded instrumentation cables – BFI (Copper/steel tape – Copper/steel mesh)
INNOVCABLE INSTRUMENTATION CABLE BFI 300V NBR 10300
1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 2 NBR NM 280 stranding
2) Insulation in thermoplastic compound based
on polyvinyl chloride (PVC/A).
3) Meeting of drivers in pairs or groups or blocks.
4) Twist pitch: 50 to 65mm.
5) Individual shielding in aluminized polyester tape, with flexible drain conductor of 0.5 mm² section, formed by tinned electrolytic copper wires.
6) Polyester tape separator.
7) Communication cable formed by a stranded conductor with a section of 0.50mm², insulation in (PVC/A) blue (when applied)
8) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1) in black.
• Insulation voltage: 300V
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
DIFFERENTIALS OF THIS PRODUCT.
– 100% virgin copper
– 100% electrolytic copper – 99.90% minimum pure (*including silver)
– High flexibility class 5 (when requested)
– Vivid colors
– Lower dielectric loss
– Lower ohmic resistance
– Flame retardant
– 100% National
– Meets Hart ® protocol (4 – 20mA), digital and point-to-point instrumentation
Identification
The pairs are made in Black and White, and the suits in Black, White and Red.
Applicable Specifications
Applications
They are used in fixed installations, in the conduction of analogue (4 – 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, powering conventional and electronic relays, in industrial environments in general.
BFI Instrumentation cables have individual shielding and are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the emergence of “crosstalk” (crosstalk) between the different pairs/terminals, providing electrical discharge of the same.
Excellent flexibility, resistance to chemicals, moisture and UV rays, flame retardant and self-extinguishing, meeting vertical flame propagation tests, according to NBR NM IEC 60332-3-23, category B.
Maximum Conductor Temperature
IN CONTINUOUS REGIME: 70ºC (PVC/A)
Notes
The BFI INSTRUMENTATION CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations.
1- Tinned copper conductor.
Stringing class 5.
2- Different sections and number of veins.
3-
Vein insulation material
/
other
temperatures :
PVC
/ E -105ºC greases and other chemicals. LSZH (non-halogenated polyolefin compound)
5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex).
INNOVCABLE INSTRUMENTATION CABLE BFI FC 300V NBR 10300
1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 2 NBR NM 280 stranding
2) Insulation in thermoplastic compound based
on polyvinyl chloride (PVC/A).
3) Meeting of drivers in pairs or groups or blocks.
4) Twist pitch: 50 to 65mm
5) Individual shielding in aluminized polyester tape, with flexible drain conductor of 0.5 mm² section, formed by tinned electrolytic copper wires.
6) Polyester tape separator.
7) Communication cable made up of a stranded conductor with a section of 0.50mm² and insulation in (PVC/A) blue color (when applied)
8) Intermediate layer in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
9) Copper tape shielding.
10) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1) in black.
• Insulation voltage: 300V
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
DIFFERENTIALS OF THIS PRODUCT.
– 100% virgin copper
– 100% electrolytic copper – 99.90% minimum pure (*including silver)
– High flexibility class 5 (when requested)
– Vivid colors
– Lower dielectric loss
– Lower ohmic resistance
– Flame retardant
– 100% National
– Meets Hart ® protocol (4 – 20mA), digital and point-to-point instrumentation
Identification
The pairs are made in Black and White, and the suits in Black, White and Red.
Applicable Specifications
Applications
They are used in fixed installations, in the conduction of analogue (4 – 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, powering conventional and electronic relays, in industrial environments in general.
BFI FC Instrumentation cables have individual shielding in aluminized polyester tape and shielding in copper tape and are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of “crosstalk” (crosstalk). ) between the various pairs/terns, providing electrical discharge to them.
Excellent flexibility, resistance to chemicals, moisture and UV rays, flame retardant and self-extinguishing, meeting vertical flame propagation tests, according to NBR NM IEC 60332-3-23, category B.
Maximum Conductor Temperature
IN CONTINUOUS REGIME: 70ºC (PVC/A)
Notes
The BFI FC INSTRUMENTATION CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations.
1- Tinned copper conductor.
Stringing class 5.
2- Different sections and number of veins.
3-
Vein insulation material
/
other
temperatures :
PVC
/ E -105ºC resistant to oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound)
5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex)
INNOVCABLE INSTRUMENTATION CABLE BFI FA 300V NBR 10300
1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 2 NBR NM 280 stranding
2) Insulation in thermoplastic compound based
on polyvinyl chloride (PVC/A).
3) Meeting of drivers in pairs, teams or blocks.
4) Twist pitch: 50 to 65mm
5) Individual shielding in aluminized polyester tape, with flexible drain conductor of 0.5 mm² section, formed by tinned electrolytic copper wires.
6) Polyester tape separator.
7) Communication cable formed by a stranded conductor with a section of 0.50mm², insulation in (PVC/A) blue color (when applied)
8) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
9) Galvanized steel strip shielding.
10) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
• Insulation voltage: 300V
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
DIFFERENTIALS OF THIS PRODUCT.
– 100% virgin copper
– 100% electrolytic copper – 99.90% minimum pure (*including silver)
– High flexibility class 5 (when requested)
– Vivid colors
– Lower dielectric loss
– Lower ohmic resistance
– Flame retardant
– 100% National
– Meets Hart ® protocol (4 – 20mA), digital and point-to-point instrumentation
Identification
The pairs are made in Black and White, and the suits in Black, White and Red.
Applicable Specifications
Applications
They are used in fixed installations, in the conduction of analogue (4 – 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, powering conventional and electronic relays, in industrial environments in general.
BFI FA Instrumentation cables have individual shielding in aluminized polyester tape and are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of “crosstalk” (crosstalk) between the different pairs /ternas/quadras, providing electrical discharge to them. It has mechanical protection with the application of galvanized steel tape, providing excellent resistance to impacts and other mechanical demands.
Flexible, resistant to chemicals, moisture and UV rays, flame-retardant and self-extinguishing, complying with vertical flame propagation tests, in accordance with NBR NM IEC 60332-3-23, category B.
Maximum Conductor Temperature
IN CONTINUOUS REGIME: 70ºC (PVC/A)
Notes
The BFI FA INSTRUMENTATION CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations.
1- Tinned copper conductor.
Stringing class 5.
2- Different sections and number of veins.
3-
Vein insulation material
/
other
temperatures :
PVC
/ E -105ºC resistant to oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound)
5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex).
INNOVCABLE INSTRUMENTATION CABLE BFI BTC 300V NBR 10300
1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 2 NBR NM 280 stranding
2) Insulation in thermoplastic compound based
on polyvinyl chloride (PVC/A).
3) Meeting of drivers in pairs, teams or blocks.
4) Twist pitch: 50 to 65mm
5) Individual shielding in aluminized polyester tape, with flexible drain conductor of 0.5 mm² section, formed by tinned electrolytic copper wires.
6) Polyester tape separator.
7) Communication cable formed by a stranded conductor with a section of 0.50mm², insulation in (PVC/A) blue color (when applied)
8) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
9) Bare copper wire mesh shielding.
10) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
• Insulation voltage: 300V
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
DIFFERENTIALS OF THIS PRODUCT.
– 100% virgin copper
– 100% electrolytic copper – 99.90% minimum pure (*including silver)
– High flexibility class 5 (when requested)
– Vivid colors
– Lower dielectric loss
– Lower ohmic resistance
– Flame retardant
– 100% National
– Meets Hart ® protocol (4 – 20mA), digital and point-to-point instrumentation
Identification
The pairs are made in Black and White, and the suits in Black, White and Red.
Applicable Specifications
Applications
They are used in fixed installations, in the conduction of analogue (4 – 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, powering conventional and electronic relays, in industrial environments in general.
BFI BTC Instrumentation cables have individual shielding in aluminized polyester tape and are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of “crosstalk” (crosstalk) between the different pairs /ternas/quadras, providing electrical discharge to them. It also has shielding in bare copper wires, providing greater flexibility. Cable resistant to chemicals, humidity and UV rays, flame-retardant and self-extinguishing, complying with vertical flame propagation tests, in accordance with NBR NM IEC 60332-3-23, category B.
Maximum Conductor Temperature
IN CONTINUOUS REGIME: 70ºC (PVC/A)
Notes
The BFI BTC INSTRUMENTATION CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations.
1- Tinned copper conductor.
Stringing class 5.
2- Different sections and number of veins.
3-
Vein insulation material
/
other
temperatures :
PVC
/ E -105ºC resistant to oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound)
5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex).
INNOVCABLE INSTRUMENTATION CABLE BFI BTA 300V NBR 10300
1) Stranded conductor formed by bare electrolytic copper wires, soft temper, class 2 NBR NM 280 stranding
2) Insulation in thermoplastic compound based
on polyvinyl chloride (PVC/A).
3) Meeting of drivers in pairs, teams or blocks.
4) Twist pitch: 50 to 65mm
5) Individual shielding in aluminized polyester tape, with flexible drain conductor of 0.5 mm² section, formed by tinned electrolytic copper wires.
6) Polyester tape separator.
7) Communication cable formed by a stranded conductor with a section of 0.50mm², insulation in (PVC/A) blue color (when applied)
8) Intermediate cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
9) Galvanized steel mesh shielding.
10) Cover in thermoplastic compound based on polyvinyl chloride (PVC/ST1).
• Insulation voltage: 300V
• Routine tests:
Electrical resistance of the conductor at 20ºC
Electrical voltage in Alternating Current
Insulation resistance.
DIFFERENTIALS OF THIS PRODUCT.
– 100% virgin copper
– 100% electrolytic copper – 99.90% minimum pure (*including silver)
– High flexibility class 5 (when requested)
– Vivid colors
– Lower dielectric loss
– Lower ohmic resistance
– Flame retardant
– 100% National
– Meets Hart ® protocol (4 – 20mA), digital and point-to-point instrumentation
Identification
The pairs are made in Black and White, and the suits in Black, White and Red.
Applicable Specifications
Applications
They are used in fixed installations, in the conduction of analogue (4 – 20mA) and digital signals, point-to-point instrumentation, Hart ® protocol, connections of various sensors and meters, powering conventional and electronic relays, in industrial environments in general.
BFI BTA Instrumentation cables have individual shielding in aluminized polyester tape and are recommended for cases where excellent levels of protection against external electromagnetic interference are required, and maximum immunity against the appearance of “crosstalk” (crosstalk) between the different pairs /ternas/quadras, providing electrical discharge to them. They have mechanical protection with the application of galvanized steel mesh, providing greater flexibility. Cable resistant to chemicals, humidity and UV rays, flame-retardant and self-extinguishing, complying with vertical flame propagation tests, in accordance with NBR NM IEC 60332-3-23, category B.
Maximum Conductor Temperature
IN CONTINUOUS REGIME: 70ºC (PVC/A)
Notes
The BFI BTA INSTRUMENTATION CABLE may be manufactured in another section, dimension or material at the customer's request. Innovcable reserves the right to change this catalog without prior notice.
CONSTRUCTION OPTIONS
We can manufacture upon request in other configurations.
1- Tinned copper conductor.
Stringing class 5.
2- Different sections and number of veins.
3-
Vein insulation material
/
other
temperatures :
PVC
/ E -105ºC resistant to oils, greases and other chemicals. LSZH (non-halogenated polyolefin compound)
5- Perfectly cylindrical cover for cable gland applications in hazardous areas (Ex).