Naval Cables – NEK-606/IEC – SHF2 Resistance

Instrumentation and Communication Cables – Fire Resistance IEC 60331 – SHF2 Resistance

    INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(c), BFBU(c), BFCU(c) – S4 and S4/S8 – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance
    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
    2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 ( Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Pairs or Trios gathered together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied to the conductors.
    5-) Collective shielding in aluminized polyester tape + drain wire (Code (c))
    6) Internal cover in halogen-free polyolefin compound LSOH – (Code F)
    7) Frame: *2
    – Mesh of tinned copper wires (Code 0)
    – Bronze wire mesh (Code B)
    – Galvanized steel wire mesh (Code C)
    8) Final cover in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    9) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS)

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BFOU(c) 250V S4/S8 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3 -22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed installations in ex (zone 0.1 and 2) areas and safety, emergency and critical systems where fire resistance requirement IEC 60331 is required.

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) The tinned copper conductor can be manufactured in class 2.
    2) Separator tape can be applied before/after the frame.
    3) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(i), BFBU(i), BFCU(i) – S3 and S3/S7 – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance
    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stranding, in accordance with IEC 60228. *1
    2-) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 ( Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
    5) Pairs or trios put together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied on drivers.
    6) Inner cover in halogen-free polyolefin compound LSOH – (Code F)
    7) Frame: *2
    – Mesh of tinned copper wires (Code 0)
    – Mesh of bronze wires (Code B)
    – Mesh of galvanized steel wires (Code C)
    8) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    9) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS)

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BFOU(c) 250V S4/S8 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3 -22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed facilities in ex areas (zone 0.1 and 2) and areas of safety, emergency and critical systems where fire resistance requirement is required IEC 60331. meets the resistance requirement Nek TS 606: 2009.Cabo Instrumentation Fire Resistance Instrumentation

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) The tinned copper conductor can be manufactured in class 2.
    2) Separator tape can be applied before/after the frame.
    3) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE Instrumentation and Communication 150/250(300)V BFOU(i&c), BFBU(i&c), BFCU(i&c) – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance
    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stringing, in accordance with IEC 60228. *1
    2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 (Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
    5) Pairs or trios put together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied on drivers.
    6) Collective shielding in aluminized polyester tape + drain wire (Code (c))
    7) Internal cover in halogen-free polyolefin compound LSOH – (Code F)
    8) Frame: *2
    – Tinned copper wire mesh (Code 0 )
    – Bronze wire mesh (Code B)
    – Galvanized steel wire mesh (Code C)
    9) Cover final in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    10) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS)

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BFOU(i&c) 250V S4/S8 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3 -22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed installations in ex (zone 0.1 and 2) areas and safety, emergency and critical systems where fire resistance requirement IEC 60331 is required.

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) The tinned copper conductor can be manufactured in class 2.
    2) Separator tape can be applied before/after the frame.
    3) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE Instrumentation and Communication 150/250(300)V BU(i) – S13 – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stringing, in accordance with IEC 60228. *1
    2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 (Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
    5) Pairs or trios put together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied on drivers.
    6) Final cover in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    7) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BU(c) 250V S13 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed installations in ex (zone 2) areas and safety, emergency and critical systems where fire resistance requirement is required IEC 60331.

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) Tinned copper Conductor can be manufactured in class 2.
    2) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE Instrumentation and Communication 150/250(300)V BU(c) – S14 – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stringing, in accordance with IEC 60228. *1
    2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 (Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Pairs or Trios gathered together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied to the conductors.
    5) Collective shielding in aluminized polyester tape + drain wire (Code (c))
    6) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    7) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS)

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BU(c) 250V S14 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed installations in ex (zone 2) areas and safety, emergency and critical systems where fire resistance requirement IEC 60331 is required.

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) Tinned copper Conductor can be manufactured in class 2.
    2) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    INNOVCABLE Instrumentation and Communication 150/250(300)V BU(i&c) – SHF2 Resistance – IEC 60331

    Cable Instrumentation Fire Resistance

    1) Conductor formed by tinned electrolytic copper wires, soft temper, class 5 stringing, in accordance with IEC 60228. *1
    2) Application of Mica ceramic and insulation of conductors in special halogen-free compound LSOH – IEC 60331 (Code B)
    3) Twisted conductors forming Pairs, Triples or Quads.
    4) Individual shielding in aluminized polyester tape + drain wire (Code (i))
    5) Pairs or trios put together and identified by sequential numbers, non-hygroscopic flame retardant filaments can be used in the construction of the conductor and tapes can be applied on drivers.
    6) Collective shielding in aluminized polyester tape + drain wire (Code (c))
    7) Final covering in halogen-free polyolefin compound LSOH (SHF2). (Code U)
    8) External cover in gray (Not Intrinsically Safe) or Blue (Intrinsically Safe – IS)

    Identification

    Conductors in colors:
    Pair: Black – Light Blue
    Trio: Black – Light Blue – Brown
    Quadra: Black – Light Blue – Brown – Gray

    Identification on the External Cover (example): “year” INNOVCABLE 01 BU(i&c) 250V 4 PAIR 0.75 mm2 FLEX – FLAME IEC 60092-376 IEC 60331-1 or IEC 60331-2 IEC 60331-21 IEC60332-3-22

    Applicable Specifications

    Design: NEK TS 606 and IEC 60092-376
    Conductor: IEC 60228 class 2 or 5
    Insulation: IEC 60092-360
    Coverage: IEC 60092-360
    Flame Resistant: IEC 60331-1, -2, -21
    Flame Retardant: IEC 60332-1-2 and IEC 60332-3-22
    Halogen Content: IEC 60754-1.2 0.5%
    Light transmission in smoke: IEC 61034-1.2, 60% >
    Cold / impact bending : CSA 22.2 No.0.3-01 (-40°C/-35°C) and IEC 60092-352 Annex E
    NEK-606

    Applications

    Instrumentation cable, communication, control and alarm, for fixed installations in ex (zone 2) areas and safety, emergency and critical systems where fire resistance requirement is required IEC 60331.

    Maximum Conductor Temperature

    90°C

    Notes

    Cable Instrumentation Fire Resistance

    1) Tinned copper Conductor can be manufactured in class 2.
    2) Operating voltage: 150/250(300)V
    **Innovcable reserves the right to change this catalog without prior notice.**

    Download Portuguese PDFDownload PDF EnglishDownload PDF Español

    Research and Knowledge Centers

    InnovCable: cutting -edge engineering for the challenges of tomorrow

     

    For engineers, researchers and students who are not content with the standard, InnovCable is positioned not only as a cable manufacturer, but as a technological partner at the forefront of innovation . We understand that in sectors such as naval and oil and gas, a cable is not just a component; It is a vital line, the backbone of complex operations that occur in the most severe environments on the planet.

    This is why our commitment to cutting -edge research is the core of everything we do.

     

    How InnovCable stands out and innovates:

    1. Strategic collaboration with the Academy and Institutes: We do not expect the future, we build it together. Innovcable maintains active partnerships with late universities such as USP, Unicamp and Unifei , and constantly dialogues with the challenges presented by centers such as Cenpes and Cepel . We finance master and doctoral projects focused on solving real problems, such as the development of new insulating materials resistant to H₂S gas degradation or modeling of umbilical cable behavior under extreme fatigue.
    2. Advanced Materials Engineering: Our laboratories go beyond compliance tests. We actively researched and developed high performance elastomeric compounds, capable of supporting abyssal pressure, saline corrosion and temperatures ranging from Arctic to Equatorial. We are pioneers in the application of LSZH compounds (Low Smoke Zero Halogen) Mud-Resistant cable lines are designed to resist the chemical attack of drilling fluids, ensuring circuit integrity for decades.
    3. Digitization and Industry 4.0 in cables: We see each cable as a smart asset. Innovcable is at the forefront of integration of fiber optic sensors (DSS/DAS) in power and umbilical cables. This allows real -time monitoring of structural integrity, temperature and vibration throughout its extent. For an operations engineer, this means the transition from corrective maintenance to predictive maintenance , avoiding catastrophic failures and optimizing production. We created digital twins of our solutions, allowing accurate simulations that accelerate commissioning and increase project reliability.
    4. Overcoming standards through innovation: For InnovCable, certifications from entities such as DNV, ABS and Bureau Veritas are not the ultimate goal, but the starting point. Our R&D team analyzes the most strict requirements and develops solutions that outweigh them, offering safety and reliability margins that give our customers peace of mind. When a new challenge arises, such as electrifying platforms to reduce emissions, our engineering team is already working with technical committees to develop high power cables that will make this vision a safe and efficient reality.

    For professionals and future engineers seeking to leave their brand, InnovCable offers more than one product: we offer an invitation to solve industry's most difficult problems by connecting the future of energy and navigation with intelligence, safety and a tireless spirit of innovation.

     Innovcable Knowledge Bases

     

    Knowledge Bases and Core Topics

     

    This section covers the theoretical and practical pillars of marine and oil & gas engineering.

    • HYDROSTATICS AND STABILITY: Principles of buoyancy, intact and damaged stability criteria (SOLAS, IMO).
    • HYDRODYNAMICS AND OFFSHORE ENGINEERING: Resistance to progress, propulsion, maneuverability, behavior at sea ( seakeeping ), and analysis of anchoring systems and dynamic positioning.
    • NAVAL AND OFFSHORE STRUCTURES: Structural analysis of hulls and platforms (fixed and floating). Fatigue, vibration and response to environmental loads.
    • NAVAL AND SUBSEA MACHINES AND SYSTEMS: Propulsion systems, power generation, subsea production systems, umbilicals and risers .
    • O&G DESIGN AND TECHNOLOGY: Exploration, drilling and production technologies in deep and ultra-deep waters.
    • SAFETY AND REGULATION: Study of international conventions (SOLAS, MARPOL) and the rules of classification societies and regulatory bodies (ANP, DPC).
    • MATERIALS AND CORROSION: Naval steels, special alloys, composite materials and corrosion protection technologies in marine environments.

     

    Databases and academic search mechanisms

     

    Essential for researching scientific articles, theses and dissertations.

     

    Prominent journals and journals

     

    • Ocean Engineering (Elsevier)
    • Journal of Ship Research (SNAME)
    • Journal of Petroleum Science and Engineering (Elsevier)
    • Journal of Marine Science and Engineering (MDPI)
    • Journal of the Brazilian Society of Naval Engineering (SOBENA)

     

    Classification and Certification Societies

     

    Entities that create rules and certify that ships, platforms and equipment are designed, built and maintained safely.

    • DNV (Det Norske Veritas): DNV – A world leader and undisputed benchmark in the energy and maritime sectors. Its standards for offshore systems are a global standard.
    • ABS (American Bureau of Shipping): ABS – A highly prestigious classification body, with a strong presence in O&G projects and a pioneer in rules for new technologies.
    • Lloyd's Register (LR): LR – One of the oldest and most respected, with extensive experience in compliance verification and risk analysis for the energy chain.
    • Bureau Veritas (BV): Bureau Veritas – A world leader in testing, inspection and certification (TIC), with a robust marine and offshore division.
    • RINA (Registro Italiano Navale): RINA – Founded in 1861, it is a global reference in certification and engineering consultancy for the naval and energy sectors.
    • ClassNK (Nippon Kaiji Kyokai): ClassNK – Japan’s main classifying agency and one of the largest in the world.
    • IACS (International Association of Classification Societies): IACS – Brings together the main societies to establish unified technical standards.

     

    Technical Standards and Regulatory Entities

     

    • IMO (International Maritime Organization): IMO – UN agency that develops global conventions for maritime safety and pollution prevention (SOLAS, MARPOL).
    • ANP (National Agency of Petroleum, Natural Gas and Biofuels): ANP – Regulatory body for the activities of the O&G industries in Brazil, essential for the technical and safety regulation of assets.
    • DPC (Directorate of Ports and Coasts): DPC – Brazilian Maritime Authority (Brazilian Navy) that establishes the standards (NORMAM) for vessels and platforms.
    • API (American Petroleum Institute): API – Main association of the US O&G industry, which establishes technical standards recognized and used worldwide.
    • ABNT (Brazilian Association of Technical Standards): ABNT Catalog – Responsible for technical standardization in Brazil.

     

    Research Giants: Top Universities

     

    National scenario

    • University of São Paulo (USP – Naval Engineering): The Polytechnic School has one of the most traditional Naval and Ocean Engineering departments in the country, conducting research in hydrodynamics, structures and vessel design.
    • Federal University of Rio de Janeiro (UFRJ – Ocean Engineering): Home to the Ocean Engineering Program and LabOceano , the deepest ocean tank in the world, a global reference for testing offshore systems.
    • State University of Campinas (Unicamp): Although it does not offer a naval course, FEM and FEEC are references in mechanical, materials and electrical engineering, with research applicable to naval machines and systems.

    International scenario

    • NTNU (Norwegian University of Science and Technology): NTNU – Considered one of the best in the world in marine engineering, it is a center of innovation in subsea technology.
    • TU Delft (Delft University of Technology) – Netherlands: TU Delft – Powerhouse in Offshore, Dredging and Maritime Engineering.
    • University of Strathclyde (UK): Strathclyde NAOME – Department of Naval Architecture, Ocean and Marine Engineering, leading in Europe.
    • Texas A&M University (USA): Recognized worldwide for its Petroleum Engineering program , covering the full range of E&P technologies.
    • Heriot-Watt University (UK): Its Institute of GeoEnergy Engineering is a global center of excellence for teaching and research in oil and gas and the energy transition.
    • University of Michigan – USA: UMich Naval Architecture – One of the most prestigious naval architecture and marine engineering schools in the USA.

     

    Research and Innovation Institutes

     

    National scenario

    • CENPES (Petrobras Research, Development and Innovation Center): CENPES – The technological brain of Petrobras, one of the largest energy research centers in the world, focusing on deepwater technologies.
    • IPT (Technological Research Institute): IPT – Performs complex tests, material analysis and development of engineering solutions for large naval and O&G structures.
    • SENAI CIMATEC: SENAI CIMATEC – Advanced technology and innovation center that works strongly with the O&G industry in robotics, automation and supercomputing.
    • CEPEL (Electric Energy Research Center): CEPEL – Crucial for the offshore sector, researching equipment for subsea electrical systems and energy integration on platforms.
    • IPqM (Navy Research Institute): IPqM – Develops military application technologies for the Brazilian Navy, such as underwater acoustics and combat systems.

    International scenario

    • SINTEF – Norway: SINTEF – One of Europe’s largest independent research institutes, conducting applied research for the energy and ocean sectors.
    • MARIN (Maritime Research Institute Netherlands) – Netherlands: MARIN – Global leader in experimental and numerical hydrodynamics research.
    • TNO (Netherlands Organisation for Applied Scientific Research) – Netherlands: TNO – Develops innovative solutions in partnership with industry, including monitoring of offshore structures and sustainable energy systems at sea.
    • HSVA (Hamburg Ship Model Basin) – Germany: HSVA – World reference in ship model testing and, especially, in ice hydrodynamics.
    InnovCable
    Privacy Overview

    This website uses cookies so that we can provide the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.