FREQUENCY INVERTER CABLES

Servo motor cables

    INNOVCABLE INNOVFREQUENCY - NBR 7286

    PHASE CONDUCTOR:
    1-) Phase conductor material : bare copper wires, soft temper. Conductor class: in accordance with DIN VDE 0295 class 5 and IEC 60228 cl. 5.

    ISOLATION:
    2-) Insulated with special compound in double layer (high modulus EPR/B) in Black, Blue and White colours. Twisted in layers.

    FILLING:
    3-) Special PVC protective intermediate cover.

    CONCENTRIC CONDUCTOR:
    4-) Helically applied copper wires. Section 50% of the phase conductor for sections greater than 16,0mm² and equal of the phase conductor for sections smaller than 16,0mm².

    BLINDING:
    5-) Copper tape of minimum thickness of 0.07mm with overlap.

    COVER:
    6-) External cover in special anti-fire PVC, resistant to bad weather and UV Rays. Black colour.

    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 0,6/1kv.
    - Voltage test: 3.000 V.
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Min. bending radius fixed use: 6 x d.
    - Flame retardant according to IEC 60332-1.

    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Alternating current electric tension
    Insulation resistance.

    Identification

    External marking in accordance with NBR 7286.
    Conductor colours: Black, Blue and White.
    Outer cover colour: Black.

    Applicable Specifications

    ABNT/MERCOSUR: NM-280 and NM-IEC
    DIN VDE 0295 class 5e IEC 60228 cl. 5
    IEC 60332-1
    ABNT: NBR 6251
    NBR 5410/2004 - Installation
    NBR 7286

    Applications

    Suitable for applications in Frequency Inverters, they have the fourth concentric conductor applied helically on the intermediate layer. In order to reduce electrostatic interference copper tape is applied, ensuring a better performance of the inverter, flexible cable and easy installation with insulation that increases the current conduction capacity.

    Maximum Conductor Temperature

    Thermal limits according to ABNT NBR 6251:
    - Permanent regime: 90ºC
    - Overload conditions: 130ºC
    - Short-circuit conditions: 250ºC

    Notes

    CONSTRUCTION OPTIONS
    We can manufacture other configurations on request, in addition to those specified below:
    1- Tinned copper conductor.
    Class 2 stranding.
    2- Different sections and number of veins, maximum up to
    3- Vein insulation material / other temperatures:
    XLPE - 90 ºC
    PE - 80 ºC
    4- Material of the intermediate layer and the cover:
    PE
    PVC/E
    PVC/ST2
    Special PVC resistant to oils, grease and other chemicals.
    LSZH (non-halogenated polyolefin compound)
    OTHER COMPOUNDS

    - Constructions below 10.0mm² do not include the copper tape, with the neutral remaining concentric in the same gauge as the conductor.

    - We can produce on request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE SERVOFLEX C PVC 1KV 4 SUPPLY COLOURS + 2 SHIELDED PAIR

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - vein insulation: PVC / control conductors: special PE
    -Power veins: black or white numbered 1, 2, 3 and green (G) // Control veins: pairs of 0,34mm² - black or white engraved BR1, BR2 // Control veins: pairs of up to 0,75mm² black or white numbered 5, 6 and 7, 8.
    - Control conductor shielding in copper mesh with attenuation ≥ 55 dB.
    -General shielding in tinned copper mesh, coverage approx. 85%.
    - Outer jacket: special PVC resistant to oils, greases, acids, coolants and lubricants.
    - Outer cover: GREY RAL7001
    - Rated voltage: Power conductors 0.6/1KV; Control conductors: 350/350V
    - Voltage test: Cable/cable 4000V - Cable/Mesh:2000V.
    - Conductor resistance: at +20 °C according to DIN VDE 0295 class 5 and IEC 60228 class 5
    -Insulation resistance: at +20 °C ≥ 20 MGΩX Km.
    - Current carrying capacity:according to DIN VDE0100.
    - Min. bending radius:7,5 x d

    Identification

    - External identification marking: INNOVCABLE SERVOFLEX C PVC n G mm² + 2 X (2 x mm²) 1Kv OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    RAL 7001
    VDE 0100
    IEC 60332-2-1
    DIN VDE 0207, 0250, 0293, 0295, 0472, 0812 resp. IEC

    Applications

    Servo motor cable with 4 power conductors + 2 shielded pairs, use in highly automated industrial processes requiring high quality and EMI shielding. Manufactured according to the specifications of leading manufacturers of servo drives / frequency inverters and control systems as well as in compliance with VDE standards. Shielded power cable with control conductors for use in temperature or brake sensors for applications and drive systems, where normal mechanical and electrical applications are required, for fixed and flexible use, not recommended for mobile applications.Flameproof and flame retardant according to IEC 60332-2-1.Resistant to oils, greases, acids, coolants and lubricants.Suitable for dry and wet environments.

    Maximum Conductor Temperature

    -30°C / +80 °C
    - Flameproof and flame retardant according to IEC 60332-2-1

    Notes

    - We can produce on request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE SERVOFLEX SK C PUR 1KV 4 SUPPLY COLOURS + 2 SHIELDED PAIR

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Reinforced insulation: INNOVLON
    - Power veins: Black or white, numbered 1, 2, 3 and green (G)
    - Control veins: black or white numbered 5, 6 and 7, 8.
    - Control conductor shielding in copper mesh, with drain wire, attenuation ≥ 55 dB.
    -General shielding in tinned copper mesh, drain wire, coverage approx. 85%.
    - Outer cover: special PUR resistant to oils, greases, acids, coolants and lubricants, non halogenous.
    - Outer layer in RAL2003 orange colour.
    - Rated voltage: Power conductors 0.6/1KV; Control conductors: 350/350V
    - Voltage rating test: cable/cable:4000V - cable/mesh:1500V - mesh/mesh:500V
    - Conductor resistance: at +20 °C according to DIN VDE 0295 class 6 and IEC 60228 class 6
    -Insulation resistance: at +20 °C ≥ 20 MGΩX Km.
    - Current carrying capacity:according to DIN VDE0100.
    - Min. bending radius:7,5 x d

    Identification

    - External identification marking: INNOVCABLE SERVOFLEX SK C PUR 4+2 -n G mm² + 2 X (2 x mm²) 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    RAL 2003
    VDE 0100
    IEC 60332-2-1
    DIN VDE 0207, 0250, 0293, 0295, 0472, 0812 resp. IEC

    Applications

    Servo motor cable with 4 power conductors + 2 shielded pairs, use in highly automated industrial processes requiring high quality and EMI shielding. Manufactured according to the specifications of leading manufacturers of servo drives / frequency inverters and control systems as well as in compliance with VDE standards. Shielded power cable with control conductors for use in temperature or brake sensors for drive, robotic and industrial applications and systems, where high mechanical and electrical applications are required, for mobile use.Flameproof and flame retardant according to IEC 60332-2-1.Resistant to oils, greases, acids, coolants and lubricants.Suitable for dry and wet environments. Long life time Excellent cost/benefit ratio. Halogen free Reduced dimensional and low weight cable.

    Maximum Conductor Temperature

    -50°C / +120 °C

    Notes

    - We can produce on request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE SERVOFLEX SK C PVC 1KV

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 6 and IEC 60228 cl. 6
    - Vein insulation: Special PVC
    - Power veins: Black or white and numbered sequentially with 1 green way (G).
    - Intermediate cover: special PVC for mobile applications.
    -General tinned copper braided shielding: approximately 85% coverage
    - Outer layer: PVC special for mobile use, resistant to oils, greases, acids, coolants and lubricants
    - Outer cover: GREY RAL7001
    - Rated voltage: 0,6/1KV
    - Voltage test: 4000V
    - Conductor resistance: at +20°C according to DIN VDE 0295 class 6 and IEC 60228 class 6
    -Insulation resistance: at +20 °C ≥ 20 MGΩX Km.
    - Current carrying capacity: according to DIN VDE0100.
    - Min. bending radius:7,5 x d

    Identification

    - External identification marking: INNOVCABLE SERVOFLEX SK C PVC
    n G mm² 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 6
    IEC 60228 CLASS 6
    RAL 7001
    VDE 0100
    IEC 60332-2-1
    DIN VDE 0207, 0250, 0293, 0295, 0472, 0812 resp. IEC

    Applications

    Cable for servo motors with normal requirements, use in highly automated industrial processes requiring high quality and EMI shielding. Manufactured according to the specifications of leading manufacturers of servo drives / frequency inverters and control systems as well as in compliance with VDE standards. Electromagnetic interference shielded power cable, compatible between units and frequency inverters with mobile applications, mobile drive systems and in the field of robotics and/or industrial installations. Flame retardant according to IEC 60332-2-1, Resistant to oils, greases, acids, coolants and lubricants, suitable for dry and wet environments. Cable with excellent cost/benefit ratio.

    Maximum Conductor Temperature

    -30°C / +80 °C

    - Flame retardant in accordance with IEC 60332-2-1

    Notes

    - We can produce on request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV BLACK

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation vein: XLPE 90° C
    - Veins coloured with green earth (G) in accordance with DIN VDE 0293-308.
    - Twisted in layers.
    - Polyester tape applied helically.
    - Armour: helically applied aluminised polyester tape and tinned copper wire armour, 85% coverage.
    - Special PVC outer cover resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)), in PT colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 0,6/1KV
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: up to 12mmØ: 5 x d; up to 20mm Ø: 7,5 x d; > 20mm Ø: 10 x d.
    - Min. bending radius if mobile: up to 12mmØ: 10 x d; up to 20mm Ø: 15 x d; > 20mm Ø: 20 x d.
    - Flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification engraving:
    INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV BLACKn (x) or (G) mm² OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    IEC 60332-1
    DIN VDE 0250

    Applications

    Cable for power, control and connections of electrical equipment, for use in servo motor systems with frequency inverter technology, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant according to IEC 60332-1. Resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Operating voltage: 0,6/1kv. Manufactured free from noxious substances and silicone. Recommended for EMC applications.

    Maximum Conductor Temperature

    -40° C / +90° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request.
    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español

    INNOVCABLE 2YSL(St)CYK-J 0.6/1KV EMV-3 PLUS BLACK

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation of the vein: XLPE
    -Seams coloured with green earth (G) in accordance with DIN VDE 0293-308.
    -Twisted in layers.
    - Helically applied polyester tape.
    - Armouring: helically applied aluminised polyester tape and tinned copper wire armour, 85% coverage.
    - Black outer cover in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Free of harmful substances and silicone.
    - Rated voltage: 0,6/1KV
    - Test voltage: 4,000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: up to 12mmØ: 5 x d; up to 20mm Ø: 7,5 x d; > 20mm Ø: 10 x d.
    - Min. bending radius if mobile: up to 12mmØ: 10 x d; up to 20mm Ø: 15 x d; > 20mm Ø: 20 x d.
    - Flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE 2YSL(St)CYK-J 0.6/1 Kv EMV BLACKn (x) or (G) mm² OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    IEC 60332-1
    DIN VDE 0250

    Applications

    Cable for power, control and connections of electrical equipment, for use in servo motor systems with frequency inverter technology, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant in accordance with IEC 60332-1. Resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Operating voltage: 0,6/1kv. Manufactured free from noxious substances and silicone. Recommended for EMC applications.

    Maximum Conductor Temperature

    -40° C / +90° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request.
    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF Portuguese Download PDF EnglishDownload PDF Español