Intrinsically safe cables
Intrinsically safe instrumentation cables
INNOVCABLE RE-2X(St)2YSWAY-fl
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- White and black veins identified by sequential numerical engraving.
- Twisted pairs in layers.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Intermediate layer in special PE, in black colour.
- Reinforced protection of galvanized steel tape
- Outer layer: special PVC, resistant to oils, grease and acids.
- BLACK or BLUE coloured PE PE inner jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius: 10 x d
Identification
- External identification engraving:
INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)2YSWAY-fl n x 2 x mm² 300V 90°C OF: XXXX/YE.
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14. It has UV protection (external use). Flameproof and flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through intermediate frame. Suitable for dry and wet environments. More stable at high frequencies and temperatures (90°C) due to XLPE (cross-linked PE) material Low attenuation and minimization of crosstalk effect due to special and differentiated shielding. Triple mechanical protection and protection against electromagnetic interference.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE RE-2X(St)2YSWBY-fl
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- White and black veins identified by sequential numerical engraving.
- Twisted pairs in layers.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Intermediate protective layer in special PE in black colour.
- Reinforced protection of galvanized steel wire braid.
- Outer cover: special PVC resistant to oils, greases, acids.
- BLACK or BLUE outer jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius:10 x d
Identification
INNOVCABLE INSTRUMENTATIONCABLE INTRINSICALLY SAFE RE-2X(St)2YSWBY-fl n x 2 x mm² 300V 90°C OF: XXXX/YE.
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14. It has UV protection (external use). Flameproof and flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through intermediate frame. Suitable for dry and wet environments. More stable at high frequencies and temperatures (90°C) due to XLPE (cross-linked PE) material Low attenuation and minimization of crosstalk effect due to special and differentiated shielding. Triple mechanical protection and protection against electromagnetic interference.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE RE-2X(St)2YSWAY-fl PiMf
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- White and black veins identified by sequential numerical engraving.
- Individual shielding of the pairs with aluminized polyester tape (PIMf) with 0.6mm tinned drain wire.
- Pairs twisted in layers.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Intermediate layer in special PE, in black colour.
- Reinforced protection of galvanized steel tape
- Outer layer: special PVC, resistant to oils, grease and acids.
- BLACK or BLUE coloured PE PE inner jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius: 10 x d
Identification
INNOVCABLE INSTRUMENTATIONCABLE INTRINSICALLY SAFE RE-2X(St)2YSWAY-fl PiMf n x 2 x mm² 300V 90°C OF: XXXX/YEAR.
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14. It has UV protection (external use). Flameproof and flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through intermediate frame. Suitable for dry and wet environments. More stable at high frequencies and temperatures (90°C) due to XLPE (cross-linked PE) material Low attenuation and minimization of crosstalk effect due to special and differentiated shielding. Triple mechanical protection and protection against electromagnetic interference.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE RE-2X(St)2YSWBY-fl PiMf
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- White and black veins identified by sequential numerical engraving.
- Individual shielding of the pairs with aluminized polyester tape (PIMf) with 0.6mm tinned drain wire.
- Pairs twisted in layers.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Protective intermediate layer in special PE in black colour.
- Reinforced protection of galvanized steel wire braid.
- Outer cover: special PVC resistant to oils, greases, acids.
- BLACK or BLUE outer jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius: 10 x d
Identification
INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)2YSWBY-fl PiMf n x 2 x mm² 300V 90°C OF: XXXX/YEAR.
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14. It has UV protection (external use). Flameproof and flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Additional mechanical protection through intermediate frame. Suitable for dry and wet environments. More stable at high frequencies and temperatures (90°C) due to XLPE (cross-linked PE) material Low attenuation and minimization of crosstalk effect due to special and differentiated shielding. Triple mechanical protection and protection against electromagnetic interference.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE RE-2X(St)Yv-fl PiMf
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- Black and white veins identified by sequential numerical engraving.
- Pairs twisted in layers.
- Individual shielding of the pairs with aluminised polyester tape (PIMf) with 0.6mm tinned drain wire.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Outer cover: special PVC resistant to oils, grease, acids.
- BLACK or BLUE coloured outer jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius: 7,5 x d
Identification
INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)Yv-fl PiMf n _ x _ x mm² 300V 90°C OF: XXXX/YEAR.
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14 (Application regulations must be observed). Features UV protection (outdoor use). Flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE - (cross-linked PE). Low attenuation and minimization of crosstalk effect Robust outer jacket.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE RE-2X(St)Yv-fl
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 4 and IEC 60228 cl. 4
- Vein insulation: XLPE (special cross-linked polyethylene) 90°C
- White and black veins identified by sequential numerical engraving.
- Twisted pairs in layers.
- General shielding in aluminized polyester tape + 0.5mm² SN drain wire.
- Outer cover: special PVC resistant to oils, grease, acids.
- BLACK or BLUE coloured outer jacket for intrinsically safe systems and as required by the application.
- Rated voltage: 300V
- Test voltage: 1.500 V
- Conductor resistance
0,5mm² - max.36,7 MΩXKm;
0,75mm² - max.25,0 MΩXKm;
1,5mm² - max.14,2 MΩXKm;
- Insulation resistance: Min.5 GΩX Km.
- Capacitance: max 115 nF/Km
- Inductivity: ca. 1mH/Km
- Coupling: max 500nF/ 500m
- Min. bending radius: 7,5 x d
Identification
INNOVCABLE INSTRUMENTATION CABLE INTRINSICALLY SAFE RE-2X(St)Yv-fl n _x _ x mm² 300V 90°C OF: XXXX/YEAR
Applicable Specifications
Applications
Instrumentation cable for lossless transmission, measurement and process control technology of analogue and digital signals. For use in intrinsically safe systems Zone 1 and Zone 2 Group II classified areas according to IEC 60079-14 (Application regulations must be observed). Features UV protection (outdoor use). Flame retardant according to IEC 60332-1-2 and IEC 60332-3-24. Resistant to oils, greases, acids. Suitable for dry and humid environments. More stable at high frequencies and temperatures (90°C) due to the material used XLPE - (cross-linked PE). Low attenuation and minimization of crosstalk effect Robust outer jacket.
Maximum Conductor Temperature
-40° C / +90° C
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24
- Can be made with other insulations:
Vein insulation material / other temperatures:
PVC/E -105ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
Notes
We can manufacture other configurations on request.
1- Tinned Copper Conductor.
Stranding class 5.
2- Different sections and number of veins.
3- Insulation material of the veins / other temperatures:
PVC/E -105 ºC
XLPE - 125 ºC
HEPR - 90 ºC
PE - 80 ºC
4- Material of the intermediate layer and the cover:
PE
PVC/E
PVC/ST2
Special PVC resistant to oils, grease and other chemicals.
LSZH (non-halogenated polyolefin compound).
5- Perfectly cylindrical cover for cable gland applications in classified areas (Ex)
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.