Intrinsically safe cables
Intrinsically safe electronic cables
INNOVCABLE INNOVTRONIC OZ EB LIYY-OZ
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
- Vein insulation: PVC esp. 105° C
- White or black veins identified by sequential numbers according to VDE 0293 without green earth (G).
- Twisted in layers.
- Outer layer: special PVC resistant to oils, grease, acids.
- Outer cover in Blue, RAL 5015.
- Rated voltage: 300/500V
- Test voltage: 3000 V
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Insulation resistance: Min.20 MΩX Km.
- Capacitance: 120nF/Km
- Inductivity: ca. 0,65mH/Km
- Min. fixed bending radius: up to 12mm 5 x d> 12mm 7,5 x d
- Min. bending radius movable: up to 12mm 10 x d up to 20mm 15 x d; . 20mm 20 x d.
Identification
INNOVCABLE - INNOVTRONIC-0Z EB LIYY-OZ n x 2 x mm² 300V OF: XXXX/YEAR
Applicable Specifications
Applications
- Cable for data transmission technology, control and connection of measuring and Instrumentation controllers for lossless data and signal transmission.
- For stationary applications and small movements.
- It has UV protection (external use).
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24.
- Resistant to oils, grease and acids.
- Suitable for dry and wet environments.
- Intrinsically safe cable for electrical circuit protection class "i" VDE 0165.
- Intrinsically safe systems are circuits where no sparks and thermal effects in normal operation can ignite the surrounding areas.
- <50 V AC e<75 V AC
- It does not meet the requirements of 2006/95/EC- CE.
Maximum Conductor Temperature
-30° C / +105° C
- Flameproof in accordance with IEC 60332-1
Notes
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.
INNOVCABLE INNOVTRONIC OZ-CY EB LIYCY-OZ
- Conductor material: bare copper wires
- Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
- Vein insulation: PVC esp. 105° C
- White or black veins identified by sequential numbers according to VDE 0293 without green earth (G).
- Twisted in layers.
- Shielding in tinned copper braid SN coverage of approximately 85%.
- Outer cover: special PVC resistant to oils, greases, acids.
- Outer layer in Blue, RAL 5015.
- Rated voltage: 300/500V
- Test voltage: 3000 V
- Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
- Insulation resistance: Min.20 MΩX Km.
- Capacitance: cable/cable 120nF/Km; cable/shield 160 nF/Km
- Inductivity: ca. 0,65mH/Km
- Min. fixed bending radius: up to 12mm 5 x d> 12mm 7,5 x d
- Min. bending radius movable: up to 12mm 10 x d up to 20mm 15 x d; . 20mm 20 x d
Identification
INNOVCABLE - INNOVTRONIC-0Z-CY EB LIYCY-OZ n x 2 x mm² 300VOF:XXXX/YEAR
Applicable Specifications
Applications
- Cable for data transmission technology, control and connection of measuring and Instrumentation controllers for lossless data and signal transmission.
- For stationary applications and small movements.
- It has UV protection (external use).
- Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24.
- Resistant to oils, grease and acids.
- Suitable for dry and wet environments.
- Intrinsically safe cable for electrical circuit protection class "i" VDE 0165.
- Intrinsically safe systems are circuits where no sparks and thermal effects in normal operation can ignite the surrounding areas.
- <50 V AC e<75 V AC
- It does not meet the requirements of 2006/95/EC- CE.
Maximum Conductor Temperature
-30° C / +105° C
- Flameproof in accordance with IEC 60332-1
Notes
- We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.