Rubber Cables

Rubber covered handles for heavy duty applications

    INNOVCABLE H07RN-F - 0,6/1KV

    - Conductor material: bare copper or tinned (SN) wires
    - Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Special Elastomeric Compound.
    - White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
    - Twisted in layers.
    - Outer jacket: CEAC™ Special Elastomeric Compound, impact resistant, flameproof - IEC 60332-1.
    - Outer cover colour BLACK, RAL 9005.
    - Rated voltage: 0.6/1KV
    - Voltage test: 3000V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min. 20 MΩX Km at 20°C.
    - Min. bending radius: according to VDE 0298 part 3

    Identification

    INNOVCABLE - H07RN-F n x mm² 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 9005
    DIN VDE 0298-3
    DIN VDE 0282-4
    acc. to IEC 60332-1

    Applications

    Cable for connecting constantly moving electrical tools and machines. It has good mechanical strength and durability, for use in wet and dry environments, for outdoor and indoor applications, in explosive areas, in industrial, agricultural, commercial and construction areas. Also suitable for fixed use, applying in temporary buildings in hoisting equipment, various devices and machines. Anti-flame.
    Made free of silicone during production.

    Maximum Conductor Temperature

    Fixed Min/max: -40° C / +125° C
    Movable Min/max: -30° C / +125° C

    Notes

    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE H07RN8-F - 0,6/1KV

    - Conductor material: bare copper or tinned (SN) wires
    - Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Special Elastomeric Compound.
    - White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
    - Twisted in layers.
    - Outer jacket: CEAC™ Special Elastomeric Compound, impact resistant, flameproof - IEC 60332-1 and for industrial water use.
    - Outer jacket in BLACK, RAL 9005 colour.
    - Rated voltage: 0.6/1KV
    - Voltage test: 3000V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min. 20 MΩX Km at 20°C.
    - Min. bending radius: according to VDE 0298 part 3

    Identification

    INNOVCABLE - H07RN8-F n x mm² 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 9005
    DIN VDE 0298-3
    DIN VDE 0282-4
    acc. to IEC 60332-1

    Applications

    Cable for connecting electrical tools and machines that move constantly and use in industrial water. It has good mechanical strength and durability, for use in wet and dry environments, for outdoor and indoor applications, in explosive areas, in industrial, agricultural, commercial and construction areas. Also suitable for fixed use, applying in temporary buildings in hoisting equipment, various devices and machines. Anti-flame.
    Made free of silicone during production.

    Maximum Conductor Temperature

    Fixed Min/max: -40° C / +125° C
    Movable Min/max: -30° C / +125° C

    Notes

    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE H07ZZ-F - 0,6/1KV

    - Conductor material: bare copper wires, soft temper.
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
    - Vein insulation: CE-30™ Cross-Linked Elastomeric Compound.
    - White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
    - Twisted in layers.
    - Outer jacket: CEAC™ Special Flame Resistant Elastomeric Compound - IEC 60332-3.
    - Outer jacket colour BLACK, RAL 9005.
    - Rated voltage: 450/750V
    - Test voltage: 2500V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min. 20 MΩX Km at 20°C.
    - Min. bending radius: according to VDE 0298 part 3

    Identification

    INNOVCABLE - H07ZZZ-Fn x mm² 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 9005
    IEC 60332-3

    Applications

    Cable for connecting electrical tools , mobile units and mechanical machines, for application in dry and wet locations, can be used outdoors, in explosive areas, in commercial and agricultural plants and in civil construction. For fixed use in provisional fixing on walls and meeting other construction needs. Good protection of people and assets.
    Made without the use of silicone during production.

    Maximum Conductor Temperature

    Fixed Min/max: -40° C / +90° C
    Mobile Min/max: -30°C / +90°C
    Flameproof in accordance with IEC 60332-3

    Notes

    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortugueseDownload PDF EnglishDownload PDF Español

    INNOVCABLE NSSHÖU - 0,6/1KV

    - Conductor material: SN tinned copper wires, soft temper.
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: CECO™ Special Elastomeric Compound
    - White or black veins identified by sequential numbering according to VDE 0293 or coloured for up to 5 conductors with or without green earth (G).
    - Twisted in layers.
    - Inner jacket: CECO™ Special Elastomeric Compound.
    - Black inner jacket
    - Outer jacket: CECO™ Special Elastomeric Compound
    - Black or yellow outer layer
    - Rated voltage: 0.6/1KV
    - Voltage test: 3000V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min. 20 MΩX Km at 20°C.
    - Min. bending radius: according to VDE 0298 part 3

    Identification

    INNOVCABLE - NSSHÖU n x mm² 0,6/1KV OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    DIN VDE 0298

    Applications

    Cable for connecting mobile units and machines with high mechanical requirements in dry and wet locations, for use outdoors and in explosive areas. Used especially in the mining industry, quarries and in construction environments. Cable with excellent durability.
    Made without the use of silicone during manufacture.

    Maximum Conductor Temperature

    Fixed Min/max: -40° C / +125° C
    Movable Min/max: -30° C / +125° C

    Notes

    - Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDFDownload PDF EnglishDownload PDF Español