Rubber Cables
Cables for permanent use in water
INNOVCABLE TML NC CABLE
– Conductor material: bare copper wires.
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound for use in water.
– White or black veins identified by sequential numbers according to VDE 0293 or colored with or without earth green (G).
TML NC: parallel conductors side by side (flat)
– External cover: CECO™ Special Elastomeric Compound.
– Outer cover in BLACK color, RAL 9005.
– TML NC: 0.6/1kV
– Voltage test: TML NC: 3 kV
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Resist . of insulation: Min. 20 MΩX Km at 20 ° C.
– Min radius. of curvature: fixed 4 xd; movement 5 xd
Identification
INNOVCABLE – TML NF nx mm² 0.6/1kV OF:XXXX/YEAR
Applicable Specifications
Applications
Cable for permanent use in water for connecting electrical equipment, such as submersible pumps, motors. Suitable in industrial water and for medium mechanical needs. Robust and excellently resistant product.
Made free of silicone during production.
TML NF: flat format
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125 ° C
Mobile Min/max: – 25° C / +125 ° C
Construction Data
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE TML N-RD CABLE
– Conductor material: bare copper wires.
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound for use in water.
– White or black veins identified by sequential numbers according to VDE 0293 or colored with or without earth green (G).
– TML N-RD: conductors twisted in layers;
– External cover: CECO™ Special Elastomeric Compound.
– External cover in BLACK, RAL 9005.
– TML N-RD: 450/750 V;
– Voltage test: TML N-RD: 2.5 kV
– Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
– Resist. of insulation: Min. 20 MΩX Km at 20 ° C.
– Min radius. of curvature: fixed 4 xd; movement 5 xd
Identification
INNOVCABLE – TML N-RD nx mm² 450/750 V OF:XXXX/YEAR.
Applicable Specifications
Applications
Cable for permanent use in water for connecting electrical equipment, such as submersible pumps, motors. Suitable in industrial water and for medium mechanical needs. Robust and excellently resistant product.
TML N-RD: nominal voltage up to 0.6 / 1 kV, when protected and fixed, and well system pipes installed.
Made free of silicone during production.
TML N-RD: round shape
Maximum Conductor Temperature
Fixed Min/max: -40° C / +125 ° C
Mobile Min/max: – 25° C / +125 ° C
Construction Data
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.