Cables for cranes, gantry cranes, overhead cranes, festoons and elevators
Cables for winders, festoons and transport systems
INNOVCABLE REELFLEX (SMK) (N)SHTÖU-J
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound for mobile use.
-Vein colors: sequentially numbered black or white veins with or without earth green.
– Conductors twisted in layers.
– central aramid element.
– Inner cover: CECO™ Special Elastomeric Compound for mobile use in black.
– Textile fabric between the inner and outer cover.
– External cover: CEAC™ Special Elastomeric Compound for mobile applications resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases, lubricants, resistance to UV, ozone and weathering.
– External cover in black or yellow.
– Nominal voltage: 0.6/1KV.
– Test voltage: 2500V
– Bending radius: in accordance with VDE 0298 part 3.
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Resist. of insulation: Min.20 MΩX Km at 20 ° C.
Fire behavior: in accordance with IEC 60332-2-1
Identification
INNOVCABLE REELFLEX(SMK) (N)SHTÖU-J n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free cable for winders/winders that require high mechanical tensile strength, highly flexible for elevators or lifting systems, festoon systems, conveyor installations, vertical spreaders, underground and surface mining, among others. Excellent lifespan and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases, lubricants, resistance to UV, ozone and weathering. Silicone-free during production. Used for speeds of up to 180 m/min. Textile tape between the inner and outer cover. Aramid central element. Tensile strength max. 30 N/mm².
Maximum Conductor Temperature
Min/max: -40°C / +130°C
Notes
– We can produce several other options and cable configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE REELFLEX PUR-HF
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: INNOVLON special compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– central textile element.
– Inner cover: PUR special for mobile use.
– Textile fabric between the inner and outer cover.
– External cover: PUR special for mobile applications, resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerant fluids, gasoline, kerosene, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 2500V
– Bending radius: Fixed use: 12 xd / Mobile use: 6 xd
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Resist. of insulation: Min.20 MΩX Km at 20 ° C.
Identification
INNOVCABLE REELFLEX PUR-HF n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free cable for heavy winders (vertical and horizontal), highly flexible for elevators or lifting systems, conveyor installations, mobile engines, railway engines and agricultural and construction site devices. Excellent lifespan and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerants, gasoline, kerosene, resistance to UV, ozone and weathering. Free of silicone during production. Reduced diameter and weight compared to other cables. Used for speeds of up to 180 m/min. Permanent tensile load without supporting elementmax. 25 N/mm². It can be applied for use in water up to 50 m deep.
Maximum Conductor Temperature
Min/max: -40°C / +90°C
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
– Upon request we can produce in PUR AC (Flame-Resistant), with fire behavior: in accordance with IEC 60332-1
INNOVCABLE REELFLEX PUR-HF SCATTER
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: INNOVLON special compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– central aramid element.
– Inner cover: PUR special for mobile use.
– Textile fabric between the inner and outer cover.
– External cover: PUR special for mobile applications, resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerant fluids, gasoline, kerosene, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 4000V
– Bending radius: Fixed use: 12 xd / Mobile use: 6 xd
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Resist. of insulation: Min.20 MΩX Km at 20 ° C.
Identification
INNOVCABLE REELFLEX PUR-HF SCATTER n (G) X mm² 0.6/1Kv OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free cable for heavy winders (vertical and horizontal), highly flexible for elevators or lifting systems, conveyor installations, vertical spreaders, mobile engines, railway engines and agricultural and construction site devices. Excellent lifespan and resistance to mechanical stress. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerants, gasoline, kerosene, resistance to UV, ozone and weathering. Free of silicone during production. Reduced diameter and weight compared to other cables. Used for speeds of up to 240 m/min, vertically 180 m/min. Textile fabric between the inner and outer cover. Permanent tensile load without supporting element max. 25 N/mm². It can be applied for use in water up to 50 m deep.
Maximum Conductor Temperature
Min/max: -40°C / +90°C
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
– Upon request we can produce in PUR AC (Flame-Resistant), with fire behavior: in accordance with IEC 60332-1
INNOVCABLE REELFLEX (K)NSHTÖU-J / (N)SHTÖU-J
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound for mobile use.
– Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Support elements: In textile fiber
– Layered twisted conductors.
– Inner cover: CECO™ Special Elastomeric Compound for mobile use.
– Anti-torsion mesh: Wide polyester mesh between the inner and outer layer.
– External cover: CECO™ Special Elastomeric Compound for mobile applications; resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 2500V
– Bending radius: in accordance with VDE 0298 part 3.
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Resist. of insulation: Min.20 MΩX Km at 20 ° C.
Identification
INNOVCABLE REELFLEX (K)NSHTÖU-J / (N)SHTÖU-J n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free cable for winders/coilers, where resistance to tensile tension and directed force tension is required at the same time. For industrial and commercial use, in civil and agricultural works, among other segments. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone and weathering. Silicone-free during production. Used for speeds of up to 120 m/min. Textile fabric between the inner and outer cover. Maximum tensile strength 20 N/mm².
Maximum Conductor Temperature
Min/max: -40°C / +130°C
Notes
– We can produce several other options and cable configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE FESTOONCABLE (N) GRDGCGÖU (C)-FC (EMV)
– Conductor material: tinned copper wires.
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound.
-Vein colors: colored veins with or without earth green (G).
– Conductors twisted in layers.
– Inner cover: CECO™ Special Elastomeric Compound for mobile applications.
– Shielding: Tinned copper mesh covering approximately 80%.
– External cover: CEAC™ Special Elastomeric Compound for mobile applications; resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 2500V
– Bending radius: in accordance with VDE 0298 part 3.
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
Fire behavior: Flame retardant in accordance with IEC 60332 -2-1
Identification
INNOVCABLE FESTOONCABLE (N) GRDGCGÖU (C)-FC (EMV) n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free power and control cable, which requires very high mechanical demands, and is often bent. It has protection against electromagnetic interference (EMI). For use in lifting systems, overhead cranes, trolleys, festoons, moving parts of machines, conveyor installations. Excellent lifespan and resistance to mechanical stress, no failures in data transmission. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone, weathering, flame retardant. Silicone-free during production.
Maximum Conductor Temperature
Min/max: -40°C / +130°C
Notes
– We can produce several other options and cable configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE FESTOONCABLE (N) GRDGÖU
– Conductor material: tinned copper wires.
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: CECO™ Special Elastomeric Compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– Shielding (only applied to Bus cables when required in the product configuration): Individually shielded Bus cables (approximate coverage of 60%) or twisted and shielded pairs (approximate coverage of 80%).
– Inner cover: CECO™ Special Elastomeric Compound for mobile applications.
– External cover: CEAC™ Special Elastomeric Compound for mobile applications, resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 2500V
– Bending radius: in accordance with VDE 0298 part 3.
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
– Fire behavior: flame retardant in accordance with IEC 60332-2-1.
Identification
INNOVCABLE FESTOONCABLE (N) GRDGÖU n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free power and control cable, which requires very high mechanical demands, and is often bent. Some formations have protection against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving parts of machines, conveyor installations, baskets. Excellent lifespan and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, splashes of oils, greases and lubricants, resistance to UV, ozone, weathering and flame retardant. Silicone-free during production.
Maximum Conductor Temperature
Min/max: -40°C / +130°C
Notes
– We can produce several other options and cable configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.
INNOVCABLE FESTOONCABLE-C-PUR-HF
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: INNOVLON special compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– Central textile element.
– Inner cover: PUR special for mobile use.
– Polyester tape + tinned copper mesh 85% coverage.
– External cover: PUR special for mobile applications; resistant to hydrolysis, oxidation, heat, abrasion, oils, greases, lubricants, refrigerant fluids, gasoline, kerosene, resistance to UV, ozone and weathering, flexible at low temperatures.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Test voltage: 2500 V
– Bending radius: Fixed use: 12 xd / Mobile use: 7.5 xd
– Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5
Identification
INNOVCABLE-FESTOONCABLE-C-PUR-HF n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free power and control cable, which requires very high mechanical demands, and is often bent. It has protection against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving parts of machines, conveyor installations. Excellent lifespan and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerants, gasoline, kerosene, resistance to UV, ozone and weathering. Free of silicone during production. Used for speeds of up to 240 m/min. Permanent tensile load without supporting element max. 25 N/mm². It can be applied for use in water up to 50 m deep.
– Also available with shielded pairs. (see table).
Maximum Conductor Temperature
Min/max: -40°C / +90°C
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice
– Upon request we can produce in PUR AC (Anti-Flame), with fire behavior: in accordance with IEC 60332-2-1
INNOVCABLE FESTOONCABLE PUR-HF
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: INNOVLON special compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– Central textile element.
– External cover: PUR special for mobile applications; resistant to hydrolysis, oxidation, heat, flexible at low temperatures, impacts, abrasion, oils, greases, lubricants, refrigerant fluids, gasoline, kerosene, UV, ozone and bad weather.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Voltage test: 2,500V
– Bending radius: Fixed use: 12 xd / Mobile use: 6 xd
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
Identification
INNOVCABLE FESTOONCABLE PUR-HF n(G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Halogen-free power and control cable, which requires very high mechanical demands, and is often bent. For use in lifting systems, trolleys, festoons, moving parts of machines, conveyor installations. Excellent lifespan and resistance to mechanical stress, used in low winding systems. Resistant to hydrolysis, oxidation, heat, flexible at low temperatures, abrasion, oils, greases, lubricants, refrigerants, gasoline, kerosene, resistance to UV, ozone and weathering. Free of silicone during production. Used for speeds of up to 240 m/min. Permanent tensile load without supporting element max. 25 N/mm². It can be applied for use in water up to 50 m deep.
Maximum Conductor Temperature
Min/max: -40°C / +90°C
Notes
– We can produce several other options and cable configurations upon request. Innovcable reserves the right to change this catalog without prior notice.
– Upon request we can produce in PUR AC (Flame-Resistant), with fire behavior: in accordance with IEC 60332-2-1
INNOVCABLE FESTOONCABLE-C-PVC-HF
– Conductor material: bare copper wires
– Conductor class: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
– Vein Isolation: INNOVLON special compound.
-Vein colors: sequentially numbered black or white veins with or without earth green (G) according to VDE 0293.
– Layered twisted conductors.
– Central textile element.
– Inner cover: special PVC for mobile use.
– Polyester tape + tinned copper mesh 85% coverage.
– External cover: Special PVC for mobile applications, resistant to oils, greases, lubricants, resistance to UV, ozone and weathering.
– Black outer cover.
– Nominal voltage: 0.6/1KV.
– Test voltage: 2500 V
– Bending radius: Fixed use: 12 xd / Mobile use: 7.5 xd
– Conductor resistance: in accordance with VDE 0295 class 5 and IEC 60228 class 5.
Fire behavior: in accordance with IEC 60332-1-2
Identification
INNOVCABLE-FESTOONCABLE-C-PVC-HF n (G) X mm² 0.6/1KV OF:XXXX/YEAR.
Applicable Specifications
Applications
Power and control cable, which requires high demands, and is often bent. It has protection against electromagnetic interference (EMI). For use in lifting systems, trolleys, festoons, moving parts of machines, conveyor installations. Good lifespan and resistance to mechanical stress, used in low winding systems. Resistant to oils, greases, lubricants, UV, ozone and weather resistance. Silicone-free during production. Used for speeds of up to 240 m/min. Permanent tensile load without supporting element max. 25 N/mm².
– Also available with shielded pairs. (see table).
Maximum Conductor Temperature
When moving – Min/max: -20° C / +70 ° C
Fixed use – Min/max: -5° C / +70 ° C
Notes
– We can produce several other options and cable configurations upon request.
– Innovcable reserves the right to change this catalog without prior notice.