Flexible Special Control Cables

Special Control Cables - PVC

    INNOVCABLE PVC JB/OB

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special 70°C - Up to 5 conductors coloured veins according to DIN VDE 0293-308; above 6 conductors Innovcable colour code with or without earth vein (G).
    -Twisted in layers.
    - Outer layer in special UV-resistant super-flexible PVC, manufactured in RAL grey 7001.
    - Manufactured free from noxious substances and silicone.
    - Nominal Voltage: up to 16,0mm² 300/500V; over 25,0mm² 0,6/1kv
    - Test voltage: 4000V
    - Short-circuit voltage: min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - min. bending radius fixed use: 4 x d
    - min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JB/OB n (x) or (G) mm² 300/500V or 0.6/1kv 70°C OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, fixed and flexible applications without traction, can be applied in dry and wet locations. It can be applied outdoors and has UV protection/resistance. Flame retardant according to IEC 60332-1. Manufactured free of noxious substances and silicone.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JB/OB PLUS

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special 70°C - Up to 5 conductors coloured veins according to DIN VDE 0293-308; above 6 conductors Innovcable colour code with or without earth vein (G).
    -Twisted in layers.
    - Special PVC cover resistant to oils, grease and acids, manufactured in RAL grey 7001.
    - Free from silicone and harmful substances.
    - Voltage rating: up to 16.0mm² 300/500V; over 25.0mm² 0.6/1kv
    - Test voltage: 4000V
    - Short-circuit voltage: min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - min. bending radius fixed use: 4 x d
    - min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JB/OB PLUS n (x) or (G) mm² 300/500V or 0.6/1kv 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Anti-flame and flame retardant. Manufactured free of harmful substances and silicone.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JB/OB YCY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special 70°C - Up to 5 conductors coloured veins according to DIN VDE 0293-308; above 6 conductors Innovcable colour code with or without earth vein (G).
    -Twisted in layers.
    - Protective intermediate layer in special PVC.
    - Shielding: shielding of tinned copper wires, 85% coverage.
    - Outer layer in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: up to 16,0mm² 300/500V; above 25,0mm² 0,6/1kv
    - Test voltage: 4000V
    - Short-circuit voltage: min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - Min. bending radius fixed use:6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green earth conductor, (x) without green earth conductor.
    External identification marking: INNOVCABLE JB/OB-YCY n (x) or (G) mm² 300/500V or 0.6/1 Kv 70°C OF:XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant in accordance with IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. Voltage test 4000V Additional mechanical protection through intermediate frame

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JB/OB YSY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special 70°C - Up to 5 conductors coloured veins according to DIN VDE 0293-308; above 6 conductors Innovcable colour code with or without earth vein (G).
    - Twisted in layers.
    - Protective intermediate layer in special PVC.
    - Armour: steel wires, 85% coverage.
    - Outer layer in special PVC resistant to oils, greases, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: up to 16,0mm² 300/500V; above 25,0mm² 0,6/1kv
    - Test voltage: 4000V
    - Short-circuit voltage: min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - Min. bending radius fixed use:6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JB/OB-YSY n (x) or (G) mm² 300/500V or 0.6/1Kv 70°C OF:XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with excellent mechanical protection, for fixed and flexible applications without traction, can be applied in dry and wet locations. UV protection (external use). Flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of noxious substances and silicone. Triple protection, steel wire armour for high mechanical protection and magnetic protection (oxidation-proof steel wires with additional internal shielding). Voltage test of 4000V.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JB/OB CY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special 70°C - Up to 5 conductors coloured veins according to DIN VDE 0293-308; above 6 conductors Innovcable colour code with or without earth vein (G).
    -Twisted in layers.
    - Shielding: tinned copper wire shielding, 85% coverage.
    - Special PVC outer jacket resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Voltage test: cable/cable 4.000 V ; cable/shield 2.000 V
    - Capacitance: cable/cable ca. 120 nF/Km; cable/shield ca. 155 nF/Km.
    - Inductance: ca. 0,67 mH/Km
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: 6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JB/OB-CY n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant in accordance with IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. 4000V voltage test.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    - Twisted in layers.
    - Outer layer in special super flexible UV resistant PVC, manufactured in the colour grey RAL 7001.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Test voltage: 4.000 V
    - Short-circuit voltage: Min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - min. bending radius fixed use: 4 x d
    - min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JZ/OZ n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, fixed and flexible applications without traction, can be applied in dry and wet locations. It can be applied outdoors and has UV protection/resistance. Fireproof and flame retardant according to IEC 60332-1.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF Português
    Download PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ PLUS

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    - Twisted in layers.
    - Outer layer in special PVC resistant to oils, greases, acids, manufactured in the colour grey RAL 7001.
    - Free from silicone and harmful substances.
    - Rated voltage: 300/500V
    - Test voltage: 4.000 V
    - Short-circuit voltage: Min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: Min. 20 MΩX Km.
    - min. bending radius fixed use: 4 x d
    - min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JZ/OZ PLUS n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, fixed and flexible applications without traction, can be applied in dry and wet locations. It can be applied outdoors and has UV protection/resistance. Flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad). Manufactured free of noxious substances and silicone.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ YSY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    - Twisted in layers.
    - Protective intermediate layer in special PVC
    - Armour: steel wires, 85% coverage.
    - Outer layer in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Test voltage: 4000V
    - Short-circuit voltage: Min. 8000V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5.
    - Insulation resistance: Min. 20 MΩX Km.
    - Min. bending radius fixed use: 6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green earth conductor, (x) without green earth conductor.
    External identification marking: INNOVCABLE JZ/OZ-YSY n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with excellent mechanical protection, for fixed and flexible applications without traction, can be applied in dry and wet locations. UV protection (external use). Flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of noxious substances and silicone. Triple protection, steel wire armour for high mechanical protection and magnetic protection (oxidation-proof steel wires with additional internal shielding). Voltage test 4000V

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ YCY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    - Twisted in layers.
    - Protective intermediate layer in special PVC.
    - Shielding: tinned copper wire shielding, 85% coverage.
    - Outer layer in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: 6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JZ/OZ-YCY n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant in accordance with IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. Voltage test 4000V Additional mechanical protection through intermediate frame

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ CY TINY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: thermoplastic compound based on polyvinyl chloride (PVC) 70ºC - White or black veins identified by sequential numerical engraving in black or yellow with or without green earth (G).
    -Twisted in layers.
    - Shielding: tinned copper wire shielding, 85% coverage.
    - External cover in thermoplastic compound based on polyvinyl chloride (PVC) Fireproof.
    - Manufactured in the colour grey RAL 7001.
    - Manufactured free of harmful substances and silicone.

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JZ/OZ-CY TINY n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Anti-flame and flame retardant. Manufactured free of noxious substances and silicone. Shielding against electromagnetic interference. Recommended for EMC applications.

    Maximum Conductor Temperature

    +70ºC

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - We can produce on request several other cable options and configurations.
    - It can be constructed with coloured veins.
    Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ CY

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    -Twisted in layers.
    - Shielding: tinned copper wire shielding, 85% coverage.
    - Special PVC outer cover resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL grey 7001 colour.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 300/500V
    - Voltage test: cable/cable 4.000 V; cable/shielding 2.000 V.
    - Capacitance: cable/cable ca. 120 nF/Km; cable/shield ca. 155 nF/Km.
    - Inductance: ca. 0,67 mH/Km
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: 6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification marking:
    INNOVCABLE JZ/OZ-CY n (x) or (G) mm² 300/500V 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, with low loss in data transmission and signal transmission, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant in accordance with IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Manufactured free of harmful substances and silicone. Protective shielding against electromagnetic interference. Recommended for EMC applications. 4000V voltage test.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC YSLYSY-JZ

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC special YI2
    - Vein colours: White or black veins identified by sequential numerical engraving in black or yellow with or without green earth conductor (G) / (G) = with 1 green earth conductor; (X) = without green earth conductor.
    -Twisted in layers.
    - Intermediate layer: special PVC TM2, grey colour (GR)
    - Frame: galvanised steel wire mesh
    - Outer layer made of special PVC TM2.
    - Outer layer manufactured in transparent (TR) or grey (GR)
    - Manufactured free from noxious substances and silicone
    - Rated voltage: 300/500V
    - Voltage test: cable/cable 3.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use: 6 x d
    - Min. bending radius if mobile: 20 x d
    - Flame retardant according to: VDE 0482-332-1-2/IEC 60332-1

    Identification

    Cable engraving: INNOVCABLE YSLYSY-JZ n (x) or (G) mm² 300/500V +70°C OF: XXXX/YEAR

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for control, power or instrumentation, armed with galvanised steel wire mesh. Can be used in fixed installations or flexible applications. Cable used for measuring, checking and controlling industrial plants and engineering systems. It has unrestricted mobility without forcing the control of movement and without exposing to tension stress. It can be applied in dry and wet locations with strict safety requirements.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without green earth conductor.
    TR= Transparent
    GR= Grey
    - We can produce on request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.
    - Under request we can manufacture at a voltage of 0,6/1KV

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ BLACK 0,6/1kV

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    -Twisted in layers.
    - Special PVC outer cover resistant to oils, grease and acids, manufactured in black.
    - Free from silicone and harmful substances.
    - Nominal voltage: 0,6/1Kv.
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - min. bending radius fixed use: 4 x d
    - min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    - External identification marking:
    INNOVCABLE JZ/OZ BLACK n (x) or (G) mm² 0.6/1Kv 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment in general, for data and signal transmission, fixed and flexible applications without traction, can be applied in dry and wet places. It can be applied in external areas with UV application. Flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad). Manufactured free of harmful substances and silicone. Operating voltage 0,6/1kv. Test voltage 4000V.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC JZ/OZ-YCY BLACK 0,6/1KV

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC 70°C - White or black veins identified by sequentially engraved numbers in black or yellow with or without green earth (G).
    -Twisted in layers.
    - Protective intermediate layer in special PVC.
    - Shielding: shielding of tinned copper wires, 85% coverage.
    - Outer layer in special PVC resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)).
    - Manufactured in RAL 7001 Black.
    - Manufactured free from noxious substances and silicone.
    - Rated voltage: 0,6/1KV
    - Test voltage: 4.000 V
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - Min. bending radius fixed use:6 x d
    - Min. bending radius if mobile: 15 x d
    - Flameproof and flame retardant according to IEC 60332-1

    Identification

    - All cables with identification (G) have 1 green conductor to earth, (x) without green conductor to earth.
    External identification engraving:
    INNOVCABLE JZ/OZ-YCY BLACK n (x) or (G) mm² 0.6/1Kv 70°C OF: XXXX/ANO

    Applicable Specifications

    DIN VDE 0295 CLASS 5
    IEC 60228 CLASS 5
    DIN VDE 0293
    RAL 7001
    IEC 60332-1
    DIN VDE 0245, 0250 AND 0281

    Applications

    Cable for power, control and connections of electrical equipment, for use in servo motor systems with frequency inverter technology, for fixed and flexible applications without traction, can be applied in dry and wet locations. It has UV protection (external use). Flame retardant according to IEC 60332-1. Resistant to oils, grease, acids and radiation (up to 80x106cJ/Kg (up to 80 Mrad)). Operating voltage: 0,6/1kv. Manufactured free from noxious substances and silicone. Recommended for EMC applications. Voltage test 4000V. Additional mechanical protection through intermediate frame.

    Maximum Conductor Temperature

    min/max: -30° C / +70° C

    Notes

    G = with 1 green conductor to earth;
    x = without a green earth conductor (OZ).
    - Several other cable options and configurations can be produced on request. Innovcable reserves the right to modify this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE PVC TRAY VTC TC-ER

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: special PVC for TC-ER application - white or black veins identified by sequentially engraved black or yellow numeric engraving with or without green earth conductor (G).
    - Twisted in layers.
    - Outer layer in special PVC for TC-ER application, resistant to oils, grease, acids, movement, flame, bad weather, UV, aurora borealis, manufactured in grey RAL 7001.
    - Manufactured free of harmful substances and silicone.
    - Rated voltage:
    UL TC: 600V
    UL WTTC: 1000V
    UL AWM/ cRU AWM: 1000V
    - Voltage test: 2000V
    - Conductor resistance: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - min. bending radius: 4 x d

    Identification

    INNOVCABLE PVC TRAY VTC 600V TC-ER ___ x ___AWG SUN RES DIR BUR ROHS OP

    Applicable Specifications

    UL: Impact and Crushing
    TC-ER per UL 1277
    WTTC per UL 2277
    AWM 20886
    UL Oil Res I
    90°C wet; 90°C dry
    Resistance to sunlight
    Aurora Borealis
    NFPA 79 2015
    NEC: Class 1 Division 2 per NEC Article 336, 392, 501
    cUL CIC FT4
    cRU AWM I/II A/B FT4
    CE & RoHS

    Applications

    Easy and cost-effective installation due to no conduit (suitable for open installation), UL TC-ER & CSA CIC compliant.
    The special PVC insulation for TC-ER applications is superior to PVC/Nylon products and allows for dimensional reduction.
    This product has torsion, oil, flame, cold, UV, aurora borealis and mechanical resistance.

    Maximum Conductor Temperature

    - UL TC /c(UL) CIC: -25°C to +90°C
    - Flexible use: -5° to +90°C
    - Fixed use: -40°C to +105°C

    Notes

    G = with 1 green conductor to earth;
    x = without green conductor to earth
    - We can produce on request several other cable options and configurations.
    - Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVTRONIC-OZ EB LIYY-OZ

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC esp. 105° C
    - White or black veins identified by sequential numbers according to VDE 0293 without green earth (G).
    - Twisted in layers.
    - Outer layer: special PVC resistant to oils, grease, acids.
    - Outer cover in Blue, RAL 5015.
    - Rated voltage: 300/500V
    - Test voltage: 3000 V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km.
    - Capacitance: 120nF/Km
    - Inductivity: ca. 0,65mH/Km
    - Min. fixed bending radius: up to 12mm 5 x d> 12mm 7,5 x d
    - Min. movable bending radius: up to 12mm 10 x d up to 20mm 15 x d; . 20mm 20 x d.

    Identification

    INNOVCABLE - INNOVTRONIC-0Z EB LIYY-OZ n x 2 x mm² 300V OF: XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    "i" VDE 0165
    RAL 5015
    IEC 60332-1

    Applications

    • Cable for data transmission technology, control and connection of measuring and Instrumentation controllers for lossless data and signal transmission.
    • For stationary applications and small movements. It has UV protection (outdoor use).
    • Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24.
    • Resistant to oils, greases, acids. Suitable for dry and wet environments.
    • Intrinsically safe cable for electrical circuit protection class 'i' VDE 0165.
    • Intrinsically safe systems are circuits where no sparks and thermal effects in normal operation can ignite the surrounding areas.
    • <50 V AC e <75 V AC
    • It does not meet the requirements of 2006/95/EC- CE

    Maximum Conductor Temperature

    -30° C / +105° C
    - Flameproof in accordance with IEC 60332-1

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE INNOVTRONIC-OZ-CY EB LIYCY-OZ

    - Conductor material: bare copper wires
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: PVC esp. 105° C
    - White or black veins identified by sequential numbers according to VDE 0293 without green earth (G).
    - Twisted in layers.
    - Shielding in tinned copper braid SN coverage of approximately 85%.
    - Outer cover: special PVC resistant to oils, greases, acids.
    - Outer layer in Blue, RAL 5015.
    - Rated voltage: 300/500V
    - Test voltage: 3000 V
    - Conductor resistance: according to VDE 0295 class 5 and IEC 60228 class 5.
    - Insulation resistance: Min.20 MΩX Km.
    - Capacitance: cable/cable 120nF/Km; cable/shield 160 nF/Km
    - Inductivity: ca. 0,65mH/Km
    - Min. fixed bending radius: up to 12mm 5 x d> 12mm 7,5 x d
    - Min. bending radius movable: up to 12mm 10 x d up to 20mm 15 x d; . 20mm 20 x d

    Identification

    INNOVCABLE - INNOVTRONIC-OZ-CY EB LIYCY-OZ n x 2 x mm² 300V OF:XXXX/YEAR.

    Applicable Specifications

    DIN VDE 0295 CLASS 4
    IEC 60228 CLASS 4
    "i" VDE 0165
    RAL 5015
    IEC 60332-1

    Applications

    • Cable for data transmission technology, control and connection of measuring and Instrumentation controllers for lossless data and signal transmission.
    • For stationary applications and small movements.
    • It has UV protection (external use).
    • Flame retardant in accordance with IEC 60332-1-2 and IEC 60332-3-24.
    • Resistant to oils, grease and acids.
    • Suitable for dry and wet environments.
    • Intrinsically safe cable for electrical circuit protection class "i" VDE 0165.
    • Intrinsically safe systems are circuits where no sparks and thermal effects in normal operation can ignite the surrounding areas.
    • It does not meet the requirements of 2006/95/EC- CE.
    • < 50 V AC e < 75 V AC

    Maximum Conductor Temperature

    -30° C / +105° C
    - Flameproof in accordance with IEC 60332-1

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español

    INNOVCABLE CABLE FOR TRAFFIC LIGHTS BS 6346

    - Conductor material: bare copper wire
    - Conductor class: According to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Vein insulation: thermoplastic compound based on polyvinyl chloride (PVC) TI1.
    - Twisted in layers.
    - Intermediate layer: Polymeric compound with a tensile strength not less than 4N / mm2 and an elongation rupture not less than 50%.
    - Frame: galvanized steel wire, 85% coverage.
    - External cover in thermoplastic compound based on polyvinyl chloride (PVC) anti-flame type TM1 in accordance with BS EN 50363
    - Manufactured in orange.
    - Manufactured free from noxious substances and silicone.

    - Insulation voltage: 600/1000V
    - Routine tests:
    Electrical resistance of the conductor at 20ºC
    Alternating current electric tension
    Insulation resistance.

    Voltage test: 4,000 V
    - Short circuit temperature: +160°C
    - Voltage drop: mV/A/m
    1,00 mm²: 25
    1.50 mm²: 38
    - Conductor resistance: according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
    - Insulation resistance: min. 20 MΩX Km.
    - min. bending radius fixed use: 6 x d

    Identification

    Conductor colours:
    4-conductor: VD/VM/AM/AZ
    6-conductor: VD/VM/AM/AZ/BC/PT
    8 conductors: VD/VM/AM/AZ/BC/PT/CZ/LJ
    12-column conductors: VD/VM/AM/AZ/BC/PT/CZ/LJ/MR/VL/RS/BJ

    Applicable Specifications

    DIN VDE 0295 class 5
    IEC 60228 cl. 5
    BS EN 50363
    BS 6346
    BS EN/IEC 60332-1-2
    BS EN 50364

    Applications

    For the interconnection of traffic signalling equipment or other applications requiring conductor configurations with mechanical robustness.

    Maximum Conductor Temperature

    min/max: -15° C / +70° C

    Notes

    - We can produce upon request several other cable options and configurations. Innovcable reserves the right to change this catalogue without prior notice.

    Download PDF PortuguêsDownload PDF EnglishDownload PDF Español